Advalab Drying Oven ADDO-531 maintains optimal storage conditions with a temperature range of 5°C to 300°C. The unit features multiple shelves that support heavy loads for efficient bulk sample handling. With 64 L storage capacity, this accommodates a wide variety of items. Constructed from high-quality corrosion-resistant materials, it ensures long-lasting durability and reliable performance. Used in research and laboratories, our Drying Oven ensures effective drying and sterilization of reagent and tools.
Volume | 64 L |
Temperature Range | RT+5 to 300°C |
Temperature Resolution | 0.1°C |
Temperature Fluctuation | ±1°C |
Temperature Uniformity | ±2.5°C |
Heating Time | Greater than 5 min |
Timer Range | 0 to 9999 mins |
Number of Shelves | 2/5 pc |
Load Per Shelf | 15 kg |
Power Consumption | 1550 kW |
Power Supply | 220±10V, 50/2Hz |
Internal Dimensions (W×D×H) | 410×350×450 mm |
Housing Dimensions (W×D×H) | 555×566×722 mm |
Package Dimensions(W×D×H) | 675×726×872 mm |
Net Weight | 42 kg |
Gross Weight | 60 kg |
Our Drying Oven ADDO-531 is used for the drying and sterilization of reagents and tools, our Drying Oven is extensively utilized in research laboratories.
1. What is the humidity level inside a drying oven during operation?
During operation, the humidity inside a drying oven is kept very low due to continuous evaporation and ventilation of moisture. This dry environment ensures effective drying of samples or materials. Some advanced drying ovens even have humidity monitoring or control systems to maintain specific drying conditions.
2. Can I use aluminum foil or metal containers in a drying oven?
Yes, you can safely use aluminum foil or metal containers in a drying oven as long as they can withstand the operating temperature. However, avoid tightly sealed containers, as pressure may build up during heating. Always ensure good airflow around the containers for even heating in the drying oven.
3. What are the common signs of malfunction in a drying oven?
Common signs of malfunction in a drying oven include inaccurate temperature readings, uneven drying, abnormal noises, or failure to reach set temperatures. Also, check for damaged seals, flickering displays, or error codes. Promptly servicing your drying oven can prevent costly breakdowns and ensure consistent performance.
4. Do drying ovens come with over-temperature protection?
Yes, most modern drying ovens are equipped with over-temperature protection to prevent overheating and protect both the equipment and the samples. This safety feature automatically shuts down or limits heating if the drying oven exceeds the preset threshold, reducing fire risk and equipment damage.
5. Can a drying oven be integrated with a computer or data logger?
Many advanced drying ovens offer connectivity options such as USB, RS232, or Ethernet ports for integration with computers or data loggers. This allows users to monitor, record, and analyze temperature profiles in real time. Such features are especially useful for documentation and quality control in regulated industries.
6. What is the difference between a drying oven and a muffle furnace?
A drying oven is used for low- to mid-temperature applications up to ~300°C, primarily for moisture removal, while a muffle furnace operates at much higher temperatures (up to 1200°C or more) for tasks like ashing, sintering, or material testing. Both look similar but serve very different thermal processing purposes.
Volume | 280 L |
Temperature Range | RT+5 to 300°C |
Temperature Resolution | 0.1°C |
$1,410.00
Volume | 456 L |
Temperature Range | RT+5 to 250°C |
Temperature Resolution | ±0.1°C |
$2,700.00
Volume | 452 L |
Temperature Range | RT+5 to 300°C |
Temperature Resolution | 0.1°C |
$2,560.00
Volume | 23 L |
Temperature Range | RT+5 to 200°C |
Temperature Resolution | 1°C |
$560.00
Capacity: | 225 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 136 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 136 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 71 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 225 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 71 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 43 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 43 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 136 L |
Temperature Range: | 5 °C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 429 L |
Temperature Range: | 5 °C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 50 L |
Temperature Range: | 50°C to 400 °C |
Time range: | 1 to 9999 min |
Capacity: | 200 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 1 to 9999 min |
Capacity: | 100 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 1 to 9999 min |
Capacity: | 624 L |
Temperature Range: | 5 °C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 31.5 L |
Temperature Range: | 5 °C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 72 L |
Temperature Range: | 5 °C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 225 L |
Temperature Range: | 5 °C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 20 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 1 to 9999 min |
Capacity: | 50 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 1 to 9999 min |
Capacity: | 200 L |
Temperature Range: | 50°C to 400 °C |
Time range: | 1 to 9999 min |
Capacity: | 624 L |
Temperature Range: | 5 °C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 640 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 1 to 9999 min |
Capacity: | 429 L |
Temperature Range: | 5 °C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 100 L |
Temperature Range: | 50°C to 400 °C |
Time range: | 1 to 9999 min |
Capacity: | 45 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 45 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 125 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 65 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 65 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 125 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 30 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 30 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 210 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 240 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 30 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 125 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 140 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 72 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 70 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 45 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 50 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 1 to 9999 min |
Capacity: | 65 L |
Temperature Range: | RT+10°C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 45 L |
Temperature Range: | RT+10°C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 45 L |
Temperature Range: | RT+10°C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 125 L |
Temperature Range: | RT+10°C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 65 L |
Temperature Range: | RT+10°C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 125 L |
Temperature Range: | RT+10°C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 30 L |
Temperature Range: | RT+10°C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 30 L |
Temperature Range: | RT+10°C to 300 °C |
Time range: | 1 to 9999 min |
Capacity: | 125 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 0 to 9999 min |
Capacity: | 85 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 0 to 9999 min |
Capacity: | 30 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 0 to 9999 min |
Capacity: | 45 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 0 to 9999 min |
Capacity: | 230 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 0 to 9999 min |
Capacity: | 65 L |
IncubatorTemperature: | RT+ 5°C to 80 °C |
Time range: | 0 to 9999 min |
Capacity: | 3070 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 0 to 9999 min |
Capacity: | 1300 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 0 to 9999 min |
Capacity: | 1870 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 0 to 9999 min |
Capacity: | 1000 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 0 to 9999 min |
Capacity: | 640 L |
Temperature Range: | 10 °C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 1000 L |
Temperature Range: | 10°C to 300 °C |
Time range: | 0 to 9999 min |
Capacity: | 1870 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 0 to 9999 min |
Capacity: | 1300 L |
Temperature Range: | 10 °C to 300 °C |
Time range: | 0 to 9999 min |
Capacity: | 640 L |
Temperature Range: | 10°C to 250 °C |
Time range: | 0 to 9999 min |
Capacity: | 54 L |
Temperature Range: | 10°C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 252 L |
Temperature Range: | 10°C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 960 L |
Temperature Range: | 10°C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 25 L |
Temperature Range: | 10°C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 54 L |
Temperature Range: | 10°C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 138 L |
Temperature Range: | 10°C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 640 L |
Temperature Range: | 10°C to 200 °C |
Time range: | 1 to 9999 min |
Capacity: | 252 L |
Temperature Range: | 10°C to 200 °C |
Time range: | 1 to 9999 min |
Volume: | 136 L |
Temperature Range: | RT+20 to 400°C |
Temperature Resolution: | 0.1°C |
$3,490.00
Volume: | 70 L |
Temperature Range: | RT+20 to 400°C |
Temperature Resolution: | 0.1°C |
$2,720.00
Volume: | 30 L |
Temperature Range: | RT+20 to 500°C |
Temperature Resolution: | 0.1°C |
$3,010.00
Volume: | 225 L |
Temperature Range: | RT+20 to 400°C |
Temperature Resolution: | 0.1°C |
$4,410.00
Volume: | 136 L |
Temperature Range: | RT+20 to 500°C |
Temperature Resolution: | 0.1°C |
$4,440.00
Volume: | 70 L |
Temperature Range: | RT+20 to 500°C |
Temperature Resolution: | 0.1°C |
$3,780.00
Volume: | 30 L |
Temperature Range: | RT+20 to 400°C |
Temperature Resolution: | 0.1°C |
$2,410.00
Temperature Range: | RT+5 to 250℃ |
Timing Range: | 0 to 9 hours |
Temperature Accuracy: | ±0.1℃ |
$2,180.00
Temperature Range: | RT+5 to 250℃ |
Timing Range: | 0 to 9 hours |
Temperature Accuracy: | ±0.1℃ |
$3,410.00