Refrigerated Low-Speed Centrifuge ADRLC-503 offers a maximum speed of 6000 rpm ensuring effective separation. It can accommodate 4 containers each with a capacity of 250 ml for efficient processing. Our centrifuge ensures precise, stable temperature regulation throughout the process, enhancing reliability for sensitive samples. It features a glove-friendly display that shows all parameters with direct RCF settings during operation.
Max Speed | 6000 rpm |
Max RCF | 5123× g |
Max Capacity | 4x250 ml |
Speed Accuracy | ±10 rpm |
Temperature Range | -20°C to +40°C |
Temperature Accuracy | ±1℃ |
Time Setting | 1s to 99h59m59s |
Noise | ≤60 dB(A) |
Power Consumption | 1200W |
Dimension | 580x640x390 mm |
Weight | 82 kg |
Refrigerated Low-Speed Centrifuge ADRLC-503 is used for sample separation and is widely used in Clinical Laboratories, Research Institutions, Pharmaceutical and Biotech Labs, Universities, and Educational Labs.
Refrigerated Low-Speed Centrifuge ADRLC-503 is used for sample separation and is widely used in Clinical Laboratories, Research Institutions, Pharmaceutical and Biotech Labs, Universities, and Educational Labs.
Rotor Type | Capacity | Max Speed (rpm) | Max RCF (×g) |
Swing out rotor 01 | 4×100ml | 5000rpm | 4650×g |
Swing out rotor 02 | 4×50ml | 5000rpm | 4650×g |
Swing out rotor 03 | 32×15ml | 4000rpm | 2980×g |
Swing out rotor 04 | 8×50ml | 4000rpm | 2980×g |
Swing out rotor 05 | 8×100ml | 4000rpm | 2980×g |
Swing out rotor 06 | 48×2~7ml blood tube | 4000rpm | 2951×g |
Swing out rotor 07 | 64×2~7ml blood tube | 4000rpm | 2951×g |
Swing out rotor 08 | 4×250ml | 4000rpm | 2980×g |
Microplate rotor 01 | 2×3×96 well plate | 4000rpm | 1971×g |
Fixed angle rotor 01 | 6×50ml | 6000rpm | 5123×g |
Fixed angle rotor 02 | 12×15ml | 6000rpm | 5123×g |
Adapter | Adapter Capacity |
Adapter 01 | 8×50ml |
Adapter 02 | 4×100ml |
Adapter 03 | 36×10ml |
Adapter 04 | 40×7ml blood tube |
Adapter 05 | 20×15ml |
Max Speed Range | 6000 rpm |
Max RCF | 6880 × g |
Max Capacity | 6 × 1000 ml |
Max Capacity | 4 tubes, each 1000 ml |
Max Speed | 6000 rpm |
Max RCF | 6693×g |
Max Speed | 5000 rpm |
Max RCF | 5200 × g |
Max Capacity | 4 × 800 ml |
Max Speed | 6000 rpm |
Max RCF | 5201× g |
Max Capacity | 4x750 ml |
Max Speed | 5000 rpm |
Max RCF | 5201× g |
Max Capacity | 4x750 ml |
Max Speed | 8000 rpm |
Max RCF | 14500 × g |
Max Capacity | 6x2400 ml / 12 blood bags / 384 blood tubes |
Max Speed: | 16000 rpm |
Max RCF: | 27520 x g |
Max Capacity: | 6x500 ml |
Temperature Range: | -20°C to +40°C |
Max Speed: | 22,000 RPM |
Max RCF: | 33,873 × g |
Max Capacity: | 6 × 100 mL |
Temperature Range: | -20°C to +40°C |
Max Speed: | 19,000 rpm |
Max RCF: | 30,367× g |
Max Capacity: | 4 x 500 ml |
Temperature Range: | -20°C to +40°C |
Max Speed: | 4500 rpm |
Max RCF: | 3380 x g |
Max Capacity: | 6 x 50 ml syringe |
Speed Accuracy: | ± 10 rpm |
Max Speed: | 4700 rpm |
Max RCF: | 2000 xg |
Max Capacity: | 12 x 7 ml (SERO rotor) |
Speed Accuracy: | ±20 rpm |
Max Speed: | 4000 rpm |
Max RCF: | 3400 xg |
Max Capacity: | 4 x 200 ml |
Speed Accuracy: | ±10 rpm |