Class A2 Biosafety Cabinet ADBC-505
Class A2 Biosafety Cabinet ADBC-505
Class A2 Biosafety Cabinet ADBC-505

Class A2 Biosafety Cabinet ADBC-505

Biosafety Laminar Cabinet ADBC-505 is precisely designed and ruggedly built this easy-to-use biosafety cabinet with high-resolution graphical display and advanced eye protection that allows for intuitive operation and has a typical wind speed range between 0.27 to ± 0.025 m/s. Equipped with pressure sensor monitoring to ensure safe and uniform airflow across the cabinet and includes both a light bulb and UV lamp.

Velocity 0.27 to 0.025 m/s
Inflow Air Speed 0.38 to 0.025 m/s
Half Peak Amplitude ≤ 3µm
Number of Colonies ≤ 0.5 dish/hr
Noise ≤ 65 dB
Purification Efficiency 100 Stages
Power Supply AC220V/50Hz/0.8KW
Filter Size 1295 × 545 × 50 mm
Air Tightness 99.99≤ E ≤99.999
Fluorescent/UV Lamp 28 W × 2 / 21 W × 1
Dimensions (W× D × H) 1500× 750 × 1950 mm
Purification Area Size 1300 × 650 × 620 mm
Illumination ≥ 700 LX
Weight 180 Kg
Wind Direction ø 200 mm
  • Designed with a unique grease-free bearing stainless steel
  • High reliability and durability
  • Simple maintenance and convenient operation
  • Safety and Sanitation
  • Works fully automatically
  • Low noise level of ≤ 65 dB
  • Equipped with a large graphical display for quick recognition
  • Furnished with fan system adjustable wind volume, a light touch type switch, and dual speed voltage
  • Accurate and affordable

Class A2 Biosafety Cabinet is extensively used in research facilities, laboratories, and educational environments. It is commonly used in pharmaceutical, hospital, and medical fields.

Similar Products of Class A2 Biosafety Cabinet

Velocity 0.38 to 0.025 m/s
Inflow Air Speed 0.38 to 0.025 m/s
Half Peak Amplitude ≤ 3µm
Velocity 0.26 to 0.025 m/s
Inflow Air Speed 0.48 to 0.025 m/s
Half Peak Amplitude ≤ 3µm
Velocity 0.27 to 0.025 m/s
Inflow Air Speed 0.48 to 0.025 m/s
Half Peak Amplitude ≤ 3µm
Velocity 0.38 to 0.025 m/s
Inflow Air Speed 0.48 to 0.025 m/s
Half Peak Amplitude ≤ 3µm

B2 Biological Safety Cabinet

Class B2 Biological Safety Cabinet ADBS-503
Velocity:0.56 m/s
Half Peak Amplitude:≤ 3µm
Precision Velocity:± 0.015 m/s
Class B2 Biological Safety Cabinet ADBS-502
Velocity:0.56 m/s
Half Peak Amplitude:≤ 3µm
Precision Velocity:± 0.015 m/s
Class B2 Biological Safety Cabinet ADBS-504
Velocity:0.56 m/s
Half Peak Amplitude:≤ 3µm
Precision Velocity:± 0.015 m/s
Class B2 Biological Safety Cabinet ADBS-501
Velocity:0.56 m/s
Half Peak Amplitude:≤ 3µm
Precision Velocity:± 0.015 m/s