Water Testing Equipment

Our Water Testing Equipment measures parameters like pH, chlorine and dissolved oxygen in water samples with high precision. Equipped with advanced sensors and calibration techniques, they provide reliable and accurate results. Their intuitive display and user-friendly interface enable convenient operation. Crafted using durable materials these units offer a long lasting and dependable performance. Ideal for wastewater treatment and environmental monitoring, they are versatile for both research and industrial applications.

Multi Parameter Water Quality Analyzer

Portable Dissolved Oxygen Meter

Portable Water Quality Analyzer

Turbidity Meter

TSS Meter

TDS Meter

Salinity Tester

Thermoreactor

pH Tester

ORP Meter

Multi Parameter Water Quality Analyzer ADMWA-501

Indication Error: ≤±5%
Repeatability: 0.03
COD Detection Method: Potassium dichromate method, Potassium permanganate method
COD Measuring Range: 10 to 15000 mg/L

Multi Parameter Water Quality Analyzer ADMWA-502

COD Test Method: Potassium dichromate method
Alkaline potassium permanganate
COD Measuring Range: 10 to 15000mg/L
0.5 to 25mg/L
COD Test Limit: 10mg/L
0.5mg/L
COD Digestion Temperature: 165℃ 20min
100℃ 30min

Multi Parameter Water Quality Analyzer ADMWA-503

COD Detection Method: Potassium dichromate method
Potassium permanganate method
COD Measuring Range: 10 to 15000 mg/L
COD Lower Limit of Measurement: 3 mg/L
COD Digestion Temperature: 165℃,20min
Multi Parameter Water Quality Analyzer ADMWA-504
Absorbance Detection Range: 0 to 3Abs
Optical Path Stability: ≤±0.005Abs/30min
Absorbance Resolution: 0.001Abs
Temperature: 0 to 50℃
ORP Meter ADOR-501
ORP Measuring Range: -1000mV to 1000mV
ORP Resolution: 1 mV
ORP measurement Accuracy: ±0.5% F.S.
Temperature Measurement Range: 0 to 100⁰C

pH Tester ADPH-501

pH Measuring Range: -2 to 16 pH
pH resolution: 0.1pH
pH indication error: ±0.2% F.S.
ORP Measuring Range: -2000 to 2000 mV

Portable Dissolved Oxygen Meter ADPOM-501

Dissolved Oxygen Concentration Measuring Range: 0 to 20 mg/L
Dissolved Oxygen Concentration Resolution: 0.01 mg/L
Dissolved Oxygen Concentration Accuracy: ≤±0.30 mg/L
Dissolved Oxygen Saturation Measuring Range: 0 to 200%

Portable Dissolved Oxygen Meter ADPOM-502

Dissolved Oxygen Measuring Range: 0 to 20 mg/L
Saturation Measuring Range: 0 to 200%
Temperature Measuring Range: 0 to 50℃
Measurement Principle: Fluorescence
Portable Dissolved Oxygen Meter ADPOM-503
Dissolved Oxygen Measuring Range: 0 to 20mg/L;0 to 200%
Resolution Ratio: 0.01mg/L;0.1%
Measurement Accuracy: 0.05mg/L;0.5%
Temperature Measurement Range: 0 to 100℃/32 to 212℉
Portable Water Quality Analyzer ADPWA-501
Test Parameter: Residual Chlorine
Measuring Range: 0.05 to 10 mg/L
Wavelength: 520 nm
Principle: N, N-diethyl-1, 4- phenylenediamine spectrophotometric method

Portable Water Quality Analyzer ADPWA-502

Test Parameter: Total Chlorine
Measuring Range: 0.05 to 10 mg/L
Wavelength: 520 nm
Principle: N, N-diethyl-1,4-phenylenediamine spectrophotometric method

Portable Water Quality Analyzer ADPWA-503

Test Parameter: Chlorine dioxide
Measuring Range: 0.1 to 5 mg/L
Wavelength: 520 nm
Principle: DPD photometric method

Portable Water Quality Analyzer ADPWA-504

Test Parameter: Ozone
Measuring Range: 0.05 to 2.5mg/L
Wavelength: 520 nm
Principle: DPD photometric method
Portable Water Quality Analyzer ADPWA-505
Test Parameter: Ammonia nitrogen
Measuring Range: 0.01 to 10mg/L
Wavelength: 420 nm
Principle: Nesslers reagent photometry
Salinity Tester ADSTR-501
Measuring Range: 0 to 10%
Measuring Temperature Range: 0 to 99℃
Resolution: 0.01%,0.1℃
Accuracy: (0 to 1.99) % ±0.1%
(2 to 4.99) % ±0.2%
(5 to 10) % ±0.5%

TDS Meter ADTDS-501

TDS Range: 0 to 9999 ppm
Conductivity Range: 0 to 9999 μS/cm
Temperature Range: 0 to 80℃ or 32 to 176℃
Resolution: 1ppm 1μS/cm

Thermoreactor ADTR-501

Temperature Control Range: Room temperature to 180℃
Digestion Temperature Range: 50 to 180℃
Temperature Control Accuracy: ±0.1℃
Temperature Tolerance: ±1℃

Thermoreactor ADTR-502

Temperature Control Range: 45 to 180℃
Digestion Temperature: 45 to 180℃
Temperature Control Accuracy: ±0.1℃
Temperature Tolerance: ±0.5℃
TSS Meter ADTSS-501
TSS Measuring Range: 0 to 1000mg/L
TSS Accuracy: ±0.3mg/L or ±8%
TSS Repeatability: <10mg/L: ≤±0.1mg/L
≥10mg/L: ≤±1%
TSS Calibration Method: 1 point calibration
Turbidity Meter ADTM-501
Measuring Range: 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU)
Accuracy: ±0.1NTU or ±5%
±0.3NTU or ±8%
Repeatability: ≤±0.1NTU at<10NTU
≤±1% at ≥10NTU
Calibration Method: Up to 4 points or 8 points (optional)