Class A2 Biosafety Cabinet ADBC-505
Class A2 Biosafety Cabinet ADBC-505
Class A2 Biosafety Cabinet ADBC-505

Class A2 Biosafety Cabinet ADBC-505

Biosafety Laminar Cabinet ADBC-505 is precisely designed and ruggedly built this easy-to-use biosafety cabinet with high-resolution graphical display and advanced eye protection that allows for intuitive operation and has a typical wind speed range between 0.27 to ± 0.025 m/s. Equipped with pressure sensor monitoring to ensure safe and uniform airflow across the cabinet and includes both a light bulb and UV lamp.


Velocity 0.27 to 0.025 m/s
Inflow Air Speed 0.38 to 0.025 m/s
Half Peak Amplitude ≤ 3µm
Number of Colonies ≤ 0.5 dish/hr
Noise ≤ 65 dB
Purification Efficiency 100 Stages
Filter Size 1295 × 545 × 50 mm
Air Tightness 99.99≤ E ≤99.999
Fluorescent/UV Lamp 28 W × 2 / 21 W × 1
Dimensions (W× D × H) 1500× 750 × 1950 mm
Purification Area Size 1300 × 650 × 620 mm
Illumination ≥ 700 LX
Weight 180 Kg
Wind Direction ø 200 mm
  • Designed with a unique grease-free bearing stainless steel
  • High reliability and durability
  • Simple maintenance and convenient operation
  • Safety and Sanitation
  • Works fully automatically
  • Low noise level of ≤ 65 dB
  • Equipped with a large graphical display for quick recognition
  • Furnished with fan system adjustable wind volume, a light touch type switch, and dual speed voltage
  • Accurate and affordable

Class A2 Biosafety Cabinet is extensively used in research facilities, laboratories, and educational environments. It is commonly used in pharmaceutical, hospital, and medical fields.

Frequently Asked Questions of Class A2 Biosafety Cabinet ADBC-505

1. What are Class II A2 Biological Safety Cabinets and where are they commonly used?

Class II A2 Biological Safety Cabinets are designed to provide protection to users, laboratory samples, and the surrounding environment from harmful contaminants. These cabinets operate by maintaining a constant inflow of air to prevent exposure to hazardous substances. While simultaneously using high-efficiency ULPA filters to purify the air being recirculated and exhausted. They are used in microbiology labs, clinical research settings and diagnostic centers.

2. Is regular maintenance required for Class II A2 Biological Safety Cabinets?

Yes, regular maintenance is crucial for Class II A2 Biological Safety Cabinets to maintain optimal performance safety. These units need regular cleaning to remove residues and prevent contamination. HEPA filters must be tested regularly to ensure they effectively trap airborne particles. Airflow patterns need to be validated periodically to ensure proper laminar flow and containment.

Similar Products of Class II A2 Biological Safety Cabinet

External Dimensions (W×D×H) 1100 × 750 × 2250 mm
Internal Dimensions (W×D×H) 940 × 600 × 660 mm
Max Opening Height 420 mm (17 inches)
External Dimension (W×D×H) 1800 × 755 × 2250 mm
Internal Dimension (W×D×H) 1625 × 600 × 660 mm
Max Opening Height 500 mm (22 inches)
External Dimension (W×D×H) 1300 × 750 × 2250 mm
Internal Dimension (W×D×H) 1150 × 600 × 660 mm
Max Opening Height 420 mm (17 inches)
External Dimension (W×D×H) 1950 × 800 × 2170 mm
Internal Dimension (W×D×H) 1800 × 600 × 660 mm
Max Opening Height 400 mm (16 inches)

Class II B2 Biological Safety Cabinet

Class II B2 Biological Safety Cabinet ADBS-504
External Dimension (W×D×H):1800 × 775 × 2250 mm
Internal Dimension (W×D×H):1625 × 600 × 660 mm
Max Opening Height:480 mm (20 inches)
Class II B2 Biological Safety Cabinet ADBS-502
External Dimension (W×D×H):1300 × 750 × 2250 mm
Internal Dimension (W×D×H):1150 × 600 × 660 mm
Max Opening Height:420 mm (17 inches)
Class II B2 Biological Safety Cabinet ADBS-501
External Dimension (W×D×H):1100 × 750 × 2250 mm
Internal Dimension (W×D×H):940 × 600 × 660 mm
Max Opening Height:420 mm (17 inches)
Class II B2 Biological Safety Cabinet ADBS-503
External Dimension (W×D×H):1500 × 750 × 2250 mm
Internal Dimension (W×D×H):1350 × 600 × 660 mm
Max Opening Height:500 mm (20 inches)