Double Beam Spectrophotometer ADDS-529
Double Beam Spectrophotometer ADDS-529
Double Beam Spectrophotometer ADDS-529

Double Beam Spectrophotometer ADDS-529

Double Beam UV-Vis Spectrophotometer ADDS-529 analyses samples across a wavelength range of 190 to 1100 nm, covering the visible to near-infrared spectrum. The sample compartment supports various cuvette sizes for flexible analysis. It offers real-time beam monitoring to reduce drift and improve reliability. This unit offers quick wavelength scanning for fast data collection. Our Double Beam Spectrophotometer is used in food testing, biotechnology, and forensics for the identification of chemical substances.


Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/1/2/4/5 nm
Wavelength Setting Auto
Wavelength Accuracy ± 0.1 nm 656.1 nm, ± 0.3 nm all
Wavelength Repeatability <= 0.1 nm
Photometric Accuracy 0.2 % T (0 to 100 % T), ± 0.002 A (0to 0.5 A), ± 0.004 A (0.5 to 1 A)
Photometric Repeatability ≤ 0.15 % T (0 to 100 % T), 0.001 A (0 to 0.5 A), 0.002 A (0.5 to 1 A)
Photometric Stability ± 0.15 % T, ± 0.002 A (0 to 0.5 A), ± 0.004 A (0.5 to 1 A)
Photometric Range 0 to 200 % T, -0.3 to 3 A, 0 to 9999 C
Stray Light <= 0.03 % T 220 nm, 360 nm
Stability ± 0.0003 A/h 500 nm
Work Mode T, A, C, E
Baseline Flatness ± 0.001 A
Noise 0.0005 A 500 nm
Scanning Speed Hi, Med, Low (Max. 3000nm/min)
Display 7-inch Colour touch screen
Light Source Deuterium and tungsten lamp
Detector Imported silicon photodiode
Cuvette Holder 10 mm Single-hole cell holder
Output USB drive, USB host, RS232
Power AC 110 to 220 V 50 to 60 Hz
Dimensions (L×B×H) 880×690×520 mm
Gross Weight 45 Kg
  • Robust mechanical design
  • High wavelength accuracy
  • Versatile sample compartment
  • Baseline correction
  • User-friendly interface

Our Double Beam Spectrophotometer ADDS-529 is used in quality control, research, and clinical labs for precise analysis of absorbance and concentration.

Accessory

Quantity

10 mm Glass cuvette

4 Pc

10 mm Quartz cuvette (UV)

2 Pc

Power cord

1 Pc

User’s manual

1 Pc

PC software

1 Pc

Frequently Asked Questions of Double Beam Spectrophotometer ADDS-529

1. What is the working principle of the Double Beam Spectrophotometer ADDS-529?

It operates on the principle of splitting a light beam into two paths—one passing through the sample and the other through a reference. This allows simultaneous measurement of both, minimizing errors due to fluctuations in light source intensity. The instrument detects the absorbance of the sample at specific wavelengths. It compares this with the reference to provide accurate and stable readings. This dual-path design enhances precision and repeatability.

2. What are the main applications of the Double Beam Spectrophotometer ADDS-529 in different fields?

The Double Beam Spectrophotometer ADDS-529 is widely used in pharmaceutical analysis, environmental testing, chemical research, food and beverage quality control, and educational labs. It helps determine the concentration of compounds by measuring their absorbance at specific wavelengths. In environmental labs, it can assess water quality by detecting pollutants. In pharmaceuticals, it ensures active ingredient consistency in drugs. Its accuracy and versatility make it suitable for both research and routine analysis.

3. How does the Double Beam Spectrophotometer ADDS-529 differ from a single beam spectrophotometer?

Unlike single beam models, the Double Beam Spectrophotometer ADDS-529 simultaneously measures both sample and reference beams, reducing measurement drift. This real-time comparison compensates for lamp intensity variations and enhances stability. It is more suitable for kinetic studies and high-precision work. While single beam spectrophotometers are simpler and more economical, the ADDS-529 offers superior performance and reliability.

4. What are the key features of the Double Beam Spectrophotometer ADDS-529?

The Double Beam Spectrophotometer ADDS-529 features a wide wavelength range, high photometric accuracy, real-time beam comparison, and user-friendly software. Its optical system ensures stable and reproducible results. It often includes a touchscreen interface and options for data export. The double beam setup allows long-term measurements without frequent recalibration. These features support reliable, high-throughput analysis in professional lab settings.

5. How should the Double Beam Spectrophotometer ADDS-529 be maintained for optimal performance?

To maintain accuracy, the instrument should be calibrated regularly and kept in a dust-free, dry environment. The sample compartment should be cleaned frequently, and the optical components should not be touched with bare hands. Software updates and regular performance checks are also recommended. Lamp life should be monitored and replaced when nearing end-of-life. Proper maintenance extends the device's lifespan and ensures consistent results.

Similar Products of Dual Beam Spectrophotometer

Display 10.1 TFT coloured capacitive touch screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Display 7-inch Colour Screen
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 2 nm
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/1/2/4/5 nm

Visible Spectrophotometer

Visible Spectrophotometer ADVS-502
Wavelength Range:320 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm
Visible Spectrophotometer ADVS-501
Wavelength Range:325 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm

Digital Spectrophotometer

Digital Spectrophotometer ADSM-501
Wavelength Range:340 to 1000 nm
Wavelength Accuracy:± 3 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-503
Wavelength Range:195 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-502
Wavelength Range:325 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9

Single Beam UV-Vis Spectrophotometer

Single Beam UV-Vis Spectrophotometer ADSS-509
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/2/4
Single Beam UV-Vis Spectrophotometer ADSS-519
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-515
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-511
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-516
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-508
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-523
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-501
Sample Volume:0.5 to 2.0 μL
Nucleic Acid Detection Range:2 to 15000 ng/μL (dsDNA) <br/> 1.32 to 9900 ng/μL (ss DNA) <br/> 1.6 to12000ng/μL (RNA)
Protein Detection Range:0.04 to 750 mg/mL (A280) <br/> 0.06 to 1119 mg/mL (BSA) <br/> 0.03 to 547 mg/mL (IgG) <br/> 0.015 to 284 mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-525
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-520
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-503
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:320 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-507
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-506
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/ 2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-512
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-502
Sample Volume:0.5μl to 2μl (recommended to use 2μl)
Nucleic Acid Detection Range:2 to 37500ng /μL (dsDNA) <br/> 1.32 to 24750 ng/μL (ss DNA) <br/> 1.6 to 30000ng/μL (RNA)
Protein Detection Range:0.04 to 750mg/mL (A280) <br/> 0.06 to 1119mg/mL (BSA) <br/> 0.03 to 547mg/mL (IgG) <br/> 0.015 to 284mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-513
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-517
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-521
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-518
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-510
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-514
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-504
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-522
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-527
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-505
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-526
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-524
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm

Split Beam Spectrophotometer

Split Beam Spectrophotometer ADSBS-501
Optical System:Split Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm