| Capacity | 2244 L |
| Temperature Range | 3 to 45℃ |
| Working Temperature | 5 to 35℃ |
| Temperature Precision | 0.1℃ |
| Temperature Fluctuation | ±0.5℃ |
| Temperature Uniformity | ±2℃ |
| Humidity Range | 50 to 90% RH |
| Humidity Precision | 1% RH |
| Humidity Fluctuation | 3% RH |
| Humidity Uniformity | 5% RH |
| Lighting | 350 μmol/m²/s at 10cm - Independently programable |
| Shelves | 2 modular lighting shelves |
| Cooling System | Air Cooled |
| Power Consumption | 5.4 kW |
| Voltage | 220VAC / 50HZ |
| Internal Dimension (W × D × H) | 1715 × 720 × 1818 mm |
| External Dimension (W × D × H) | 2520 × 1220 × 2220 mm |
| Net Weight | 670 kg |
| Gross Weight | 800 Kkg |
Plant Growth Chamber ADPGC-511 offers precise control of temperature, humidity, and lighting for optimized plant cultivation. It supports reliable and customizable environments for research purposes.
Accessory Description Quantity LED-01 450 nm LED light 1 Pc LED-02 660 nm LED light 1 Pc LED-03 735 nm LED light 1 Pc
1. What are Plant Growth Chambers?
Plant Growth Chambers are specialized enclosures designed to maintain controlled environmental conditions, including temperature, humidity, and lighting. They are used for conducting experiments and research on plant growth, seed germination, and microbial cultures. These units ensure consistent conditions for reproducible results in scientific studies.
2. Where are Plant Growth Chambers applied in industry?
In industrial settings, Plant Growth Chambers are used for seed quality testing, crop improvement trials, and pharmaceutical plant-based product development. They support quality inspection for materials like wood, textiles, and building components under controlled environmental simulations. Such applications help improve product standards and agricultural outputs.
| Capacity | 250 L |
| Temperature Range |
With illumination 10 to 65 °C Without illumination 5 to 65 °C |
| Humidity Range | 45 to 95 % RH |
| Capacity | 150 L |
| Temperature Range |
With illumination 10 to 65 °C Without illumination 5 to 65 °C |
| Humidity Range | 45 to 95 % RH |
| Capacity | 250 L |
| Temperature Range |
With illumination 10 to 65 °C Without illumination 5 to 65 °C |
| Humidity Range | 45 to 95 % RH |
| Capacity | 350 L |
| Temperature Range |
With illumination 10 to 65 °C Without illumination 5 to 65 °C |
| Humidity Range | 45 to 95 % RH |
| Capacity: | 310 L |
| Temperature Range: | 0 °C to 50 °C |
| Uniformity: | ± 0.1 °C |
| Capacity: | 1000 L |
| Temperature Range: | 0 °C to 50 °C |
| Uniformity: | ± 0.1 °C |
| Capacity: | 268 L |
| Temperature Range: | 0 °C to 50 °C |
| Uniformity: | ± 0.1 °C |
| Temperature Range: | 0 °C to 65 °C(with lighting), 0 to 60℃ (without lighting) |
| Humidity Range: | 40 to 95% RH |
| Illumination Range: | 0 to 15000 Lux (five-stage adjustable) |
| Capacity: | 500 L |
| Temperature Range: | 0 °C to 50 °C |
| Uniformity: | ± 0.1 °C |
| Temperature Range: | 0 °C to 65 °C(with lighting), 0 to 60℃ (without lighting) |
| Humidity Range: | 40 to 95% RH |
| Illumination Range: | 0 to 15000 Lux (five-stage adjustable) |
| Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
| Humidity Range: | 40 to 95% RH |
| Illumination Range : | 0 to 15000 Lux (five-stage adjustable) |
| Volume: | 150 L |
| Ambient Temperature: | 10 to 30°C |
| Temperature Without Humidifying: | 4 to 60°C |
| Volume: | 400 L |
| Ambient Temperature: | 10 to 30°C |
| Temperature Without Humidifying: | 4 to 60°C |
| Volume: | 250 L |
| Ambient Temperature: | 10 to 30°C |
| Temperature Without Humidifying: | 4 to 60°C |
| Capacity: | 450L |
| Temperature Range: | 0 to 9.9℃ |
| Temperature Fluctuation: | ±1.0° C |
| Capacity: | 1600 L |
| Temperature Control Range: | 0 to 9.9 ℃ |
| Temperature Fluctuations: | ± 1.0 ℃ |