The Artificial Climate Chamber ADAL-507 provides a temperature range of 0 to 60℃ without lighting for uniform airflow. It is equipped with a thirty-stage microprocessor-based PID controller to control environmental conditions. The unit features a double-layer insulation design to reduce energy consumption Equipped with a configurable timer range, it supports time-based programming and automation. Our Artificial Climate Chamber is ideal for biological tissue studies, seed germination, and animal and insect rearing.
Temperature Range | 0 °C to 65 °C(with lighting), 0 to 60℃ (without lighting) |
Humidity Range | 40 to 95% RH |
Illumination Range | 0 to 15000 Lux (five-stage adjustable) |
Temperature Accuracy | ±0.1℃ |
Temperature Fluctuation | ±1℃ (within 10 to 40℃) |
Temperature Uniformity | ±1℃ (within 10 to 40℃) |
Humidity Fluctuation | ±3% RH |
Timer Range | 0 to 99 hours |
Internal Volume | 400 Liters |
Working Environment | 10 to 30℃ |
Power Consumption | 1550 W |
Power Supply | AC 220V to 50Hz |
Internal Dimensions (H×W×D) | 1148 × 554 × 610 mm |
External Dimensions (H×W×D) | 1828 × 783 × 905 mm |
Shipping Dimensions (H×W×D) | 2017 × 880 × 1060 mm |
Net Weight | 194 kg |
Gross Weight | 214 Kg |
The Artificial Climate Chamber ADAL-507 is widely utilized in laboratories and research environments where precise regulation of temperature, humidity, and lighting is essential.
ALLSENSTM Software
Portable Printer 1 unit LCD Touch Screen Controller 1 unit Power Supply Interface 1 unit
1. What are the installation and space requirements for the Artificial Climate Chamber?
Installation of the Artificial Climate Chamber requires a stable surface, adequate ventilation, and operation within an ambient temperature of 10–30°C and humidity below 70%. The unit needs access to AC power supply and a drainage outlet for condensation management. Space should be allocated for air circulation. The compact vertical design makes it suitable for labs with limited floor space.
2. What are the main components of an Artificial Climate Chamber?
An Artificial Climate Chamber typically includes components such as a refrigeration system, humidifier, lighting system, and an internal circulation fan. The PID controller ensures stable and precise environmental regulation. LED systems simulate day-night cycles, while refrigeration and humidity systems control temperature and moisture levels. The use of stainless-steel interiors and eco-friendly insulation enhances environmental performance.
3. How does the Artificial Climate Chamber function benefit long-term use?
The Artificial Climate Chamber has an auto-defrost function that uses rapid heat pump defrost technology to prevent frost buildup on the evaporator during operation. This is crucial for long-duration experiments as it maintains consistent performance without intervention. Frost accumulation can affect temperature uniformity and airflow, so automated defrosting ensures uninterrupted accuracy.
4. What makes the Artificial Climate Chamber suitable for seed germination and plant growth?
The Artificial Climate Chamber creates a stable, controlled environment that closely mimics natural growth conditions. With a temperature range of 10 to 65°C, humidity range of 40 to 95% RH, and adjustable lighting. The chamber’s multi-segment programmable control allows timing of light and humidity changes, essential for seasonal variations. This makes it ideal for agricultural experiments, genetic research, and commercial plant trials.
5. What safety features are included in the Artificial Climate Chamber?
The Artificial Climate Chamber includes multiple security systems to protect both the equipment and samples. These may include over-temperature protection, sensor error alarms, door open alerts, and power failure recovery. Some models include password-protected settings to avoid unauthorized parameter changes. These features ensure safe operation in research environments where reliable conditions are critical.
Temperature Range | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
Humidity Range | 40 to 95% RH |
Illumination Range | 0 to 15000 Lux (five-stage adjustable) |
Capacity | 500 L |
Temperature Range | 0 °C to 50 °C |
Uniformity | ± 0.1 °C |
Temperature Range | 0 °C to 65 °C(with lighting), 0 to 60℃ (without lighting) |
Humidity Range | 40 to 95% RH |
Illumination Range | 0 to 15000 Lux (five-stage adjustable) |
Capacity | 310 L |
Temperature Range | 0 °C to 50 °C |
Uniformity | ± 0.1 °C |
Capacity: | 300L |
Temperature Range: | With Lighting: 10 to 50℃<br/> Without lighting: 4 to 50℃ |
Display Resolution: | 0.1℃ |
Capacity: | 300L |
Temperature Range: | With Lighting: 10 to 50℃<br/> Without lighting: 4 to 50℃ |
Display Resolution: | 0.1℃ |
Capacity: | 300L |
Temperature Range: | With Lighting: 10 to 50℃<br/> Without lighting: 4 to 50℃ |
Display Resolution: | 0.1℃ |
Volume: | 400 L |
Ambient Temperature: | 10 to 30°C |
Temperature Without Humidifying: | 4 to 60°C |
USD 5,300.00
Volume: | 250 L |
Ambient Temperature: | 10 to 30°C |
Temperature Without Humidifying: | 4 to 60°C |
USD 4,230.00
Volume: | 150 L |
Ambient Temperature: | 10 to 30°C |
Temperature Without Humidifying: | 4 to 60°C |
USD 3,700.00