| Capacity | 150 L |
| Temperature Range |
With illumination 10 to 65 °C Without illumination 5 to 65 °C |
| Humidity Range | 45 to 95 % RH |
| Illuminance | 0 to 10,000 LX |
| Temperature Stability | ±1 °C |
| Humidity Stability | ±3 % RH |
| Power Consumption | 800 W |
| Power Supply | AC 220 V 50 Hz or AC 110 V 60 Hz |
| Interior Dimensions (D×W×H) | 400 × 500 × 750 mm |
| Exterior Dimensions (D×W×H) | 640 × 660 × 1420 mm |
| Shipping Dimensions (D×W×H) | 690 × 730 × 1550 mm |
| Net Weight | 84 kg |
| Gross Weight | 96 kg |
The Plant Growth Chamber ADPGC-502 is utilized in plant research laboratories to regulate temperature, humidity, and illumination for experiments such as seed sprouting and microbial cultivation studies.
1. Is the Plant Growth Chamber ADPGC-502 energy efficient?
Plant Growth Chamber ADPGC-502 operates with a 800-watt power consumption, balancing performance with low energy usage. Its design minimizes heat loss, ensuring efficient climate regulation. The eco-friendly, fluorine-free compressor reduces environmental impact. Optimized airflow reduces operational strain and power draw. This efficiency supports cost-effective and sustainable laboratory operations.
2. Can the Plant Growth Chamber ADPGC-502 run long experiments?
Plant Growth Chamber ADPGC-502 is designed for extended experimental runs without performance loss. Its balanced cooling and heating prevent temperature drift over time. Intelligent frost prevention keeps the chamber clear during prolonged operation. The programmable controller allows up to 30 segment cycles for long-term studies.
3. How user-friendly is the Plant Growth Chamber ADPGC-502?
Plant Growth Chamber ADPGC-502 includes a digital microcomputer control panel for precise adjustments. Bright display screens provide clear readouts of temperature, humidity, and light levels. The one-button drainage simplifies maintenance after use. Transparent glass doors allow easy observation without disturbing conditions. Overall, it is built for convenient operation and quick setup.
4. What materials are used in the Plant Growth Chamber ADPGC-502?
The Plant Growth Chamber ADPGC-502 features a premium steel exterior coated with electrostatic powder paint for durability. Inside, stainless steel walls resist corrosion and aging. The unit smooth surfaces make cleaning straightforward. Arc-shaped internal edges improve airflow and prevent debris accumulation. This robust construction ensures longevity under heavy lab usage.
5. What is the capacity of the Plant Growth Chamber ADPGC-502?
Plant Growth Chamber ADPGC-502 offers an internal capacity of 150 liters, providing ample space for diverse controlled-environment experiments. Its size is ideal for plant research, seed germination, and microorganism preservation. The unit design supports optimal airflow for uniform conditions. This ensures consistent results across all stored samples.
6. What are Plant Growth Chambers?
Plant Growth Chambers are specialized enclosures designed to maintain controlled environmental conditions, including temperature, humidity, and lighting. They are used for conducting experiments and research on plant growth, seed germination, and microbial cultures. These units ensure consistent conditions for reproducible results in scientific studies.
7. Where are Plant Growth Chambers applied in industry?
In industrial settings, Plant Growth Chambers are used for seed quality testing, crop improvement trials, and pharmaceutical plant-based product development. They support quality inspection for materials like wood, textiles, and building components under controlled environmental simulations. Such applications help improve product standards and agricultural outputs.
| Capacity | 350 L |
| Temperature Range |
With illumination 10 to 65 °C Without illumination 5 to 65 °C |
| Humidity Range | 45 to 95 % RH |
| Capacity | 2244 L |
| Temperature Range | 3 to 45℃ |
| Working Temperature | 5 to 35℃ |
| Capacity | 450 L |
| Temperature Range |
With illumination 10 to 65 °C Without illumination 5 to 65 °C |
| Humidity Range | 45 to 95 % RH |
| Capacity | 250 L |
| Temperature Range |
With illumination 10 to 65 °C Without illumination 5 to 65 °C |
| Humidity Range | 45 to 95 % RH |
| Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
| Humidity Range: | 40 to 95% RH |
| Illumination Range : | 0 to 15000 Lux (five-stage adjustable) |
| Capacity: | 500 L |
| Temperature Range: | 0 °C to 50 °C |
| Uniformity: | ± 0.1 °C |
| Capacity: | 310 L |
| Temperature Range: | 0 °C to 50 °C |
| Uniformity: | ± 0.1 °C |
| Temperature Range: | 0 °C to 65 °C(with lighting), 0 to 60℃ (without lighting) |
| Humidity Range: | 40 to 95% RH |
| Illumination Range: | 0 to 15000 Lux (five-stage adjustable) |
| Temperature Range: | 0 °C to 65 °C(with lighting), 0 to 60℃ (without lighting) |
| Humidity Range: | 40 to 95% RH |
| Illumination Range: | 0 to 15000 Lux (five-stage adjustable) |
| Capacity: | 1000 L |
| Temperature Range: | 0 °C to 50 °C |
| Uniformity: | ± 0.1 °C |
| Capacity: | 268 L |
| Temperature Range: | 0 °C to 50 °C |
| Uniformity: | ± 0.1 °C |
| Volume: | 250 L |
| Ambient Temperature: | 10 to 30°C |
| Temperature Without Humidifying: | 4 to 60°C |
| Volume: | 400 L |
| Ambient Temperature: | 10 to 30°C |
| Temperature Without Humidifying: | 4 to 60°C |
| Volume: | 150 L |
| Ambient Temperature: | 10 to 30°C |
| Temperature Without Humidifying: | 4 to 60°C |
| Capacity: | 1600 L |
| Temperature Control Range: | 0 to 9.9 ℃ |
| Temperature Fluctuations: | ± 1.0 ℃ |
| Capacity: | 450L |
| Temperature Range: | 0 to 9.9℃ |
| Temperature Fluctuation: | ±1.0° C |