The Flame Photometer ADFP-506 delivers a test range of 0.18–100 ppm for Na and 0.15–100 ppm for K, ensuring accurate measurement for essential alkali metals. Its response time supports rapid analysis without compromising precision. Reproducibility within ±2% guarantees consistent performance across repeated tests. The system operates with LPG fuel, ensuring a stable flame and continuous operation. It is ideal for routine and advanced elemental analysis in clinical diagnostics, agricultural testing and food quality laboratories.


Testing Elements K, Na
Channels 2
Display Value Concentration / Flame Intensity
Measuring Range K: 0.15 – 100 ppm
Na: 0.18 – 100 ppm
Detection Time K: ≤0.156
Na: ≤ 0.184
Linearity Error K: ≤0.195 ppm
Na: ≤0.69 ppm
Display Digital LCD
Response Time ≤ 8 s
Aspiration Rate < 3 mL/min
Stability ≤3% (15 s), ≤5% (6 min)
Reproducibility ≤2%
Calibration Curve Automatic Linear Calibration
Fuel Supply LPG + External Air Compressor
Output USB / Printer Interface
Power Supply AC 220 V ±10%, 50 Hz ±1 Hz, 30 W
Dimensions (L×B×H) 570 × 530 × 400 mm
Net Weight 18 kg
Gross Weight 20 kg 20 kg
  • Fast-responsive
  • Trace-sensitive
  • Precision-calibrated
  • Stable-performance
  • User-integrated

Flame Photometer ADFP-506 is widely applied in clinical laboratories, food and beverage testing, petrochemical studies, and agricultural research. It enables accurate and reliable sodium and potassium monitoring in liquid samples supporting elemental analysis.

Flame Photometer ADFP-506
Flame Photometer ADFP-506

Frequently Asked Questions of Flame Photometer ADFP-506

1. What elements can the Flame Photometer ADFP-506 measure, and why are they important?

The Flame Photometer ADFP-506 measures sodium and potassium concentrations in liquid samples with exceptional accuracy. These electrolytes are vital in clinical diagnostics for monitoring patient health, in food and beverage testing for quality compliance, in petrochemical formulations for product integrity, and in agriculture for soil and fertilizer analysis. Accurate measurement ensures reliability in both regulatory compliance and advanced research applications.

2. How does the Flame Photometer ADFP-506 ensure fast and accurate analysis?

The Flame Photometer ADFP-506 delivers results in ?8 seconds, ensuring rapid sample turnaround without sacrificing accuracy. Its optimized optical system reduces linearity error to ?3%, while a stable calibration curve enhances reproducibility. With high sensitivity for trace-level detection, it is perfectly suited for laboratories handling large workloads, where both speed and precision are essential.

3. Can the Flame Photometer ADFP-506 be relied upon for continuous laboratory use?

The Flame Photometer ADFP-506 is built for continuous operation with ?2% reproducibility and a rugged design. Its low aspiration rate (<3ml/min) reduces sample consumption, and the reliable LPG fuel supply ensures uninterrupted flame generation. These features make it ideal for high-throughput environments such as clinical labs, industrial testing facilities, and research centers, where consistency and durability are paramount.

4. How does the Flame Photometer ADFP-506 maintain stability under environmental variations?

The Flame Photometer ADFP-506 incorporates intelligent optics and flame control technology that minimize drift caused by laboratory temperature or environmental fluctuations. This stability allows consistent results across a wide range of operating conditions, ensuring dependable performance in industrial, agricultural, and pharmaceutical labs, where accuracy must be maintained even under varying conditions.

5. Which industries benefit most from the Flame Photometer ADFP-506?

The Flame Photometer ADFP-506 is widely applied across multiple industries. Clinical laboratories use it for routine electrolyte monitoring in patients, while the food and beverage industry rely on it to regulate sodium content for safety standards. Petrochemical industries apply it in chemical formulation analysis, and in agriculture, it is used for soil and fertilizer evaluation. With its balance of precision, speed, and reproducibility, it is a trusted tool in both routine QC and advanced research laboratories.

6. What are the typical applications of a flame photometers?

Flame photometers are commonly used in clinical laboratories to analyze blood serum for electrolyte levels. They are also widely applied in agriculture for soil and fertilizer analysis. In the food industry, they help assess mineral content in products. Environmental monitoring labs use them to check water and waste samples for contamination. Their ease of use and quick results make them ideal for routine elemental analysis.

7. How should samples be prepared for flame photometers?

Samples must be in a liquid form, typically aqueous solutions, and free from particulates or organic solvents that might interfere with the flame. If the sample contains solids, it should be filtered or centrifuged. For accurate measurements, samples are usually diluted to fall within the linear calibration range. Calibration standards with known element concentrations are prepared similarly.

8. What are the limitations of a flame photometer?

Flame photometers have limited elemental detection capabilities, primarily restricted to a few metals. They cannot detect non-metallic elements or transition metals effectively. Interferences from other ions, emission overlap, or matrix effects can affect accuracy. The method requires careful calibration and flame stability for precise results. Also, they are less sensitive compared to techniques like ICP-OES or AAS.

9. Which elements can be measured using a flame photometers?

Flame photometers primarily measure alkali and alkaline earth metals, including sodium (Na), potassium (K), calcium (Ca), and lithium (Li). Some models can also measure barium (Ba) and rubidium (Rb) with proper filters. These elements emit characteristic light when introduced into a flame. The photometer detects this light to determine their concentration.

10. What is a flame photometers and how does it work?

flame photometers are analytical instruments used to detect and measure the concentration of certain metal ions, mainly sodium, potassium, lithium, and calcium, in a solution. It operates on the principle of flame emission spectrometry, where a sample is aspirated into a flame and the emitted light intensity is measured. The emitted light is specific to each element and correlates with its concentration.

Similar Products of Flame Photometers

Testing Elements K, Na, Li
Channels 3
Display Value Concentration / Flame Intensity
Testing Elements K, Na, Li, Ca
Channels 4
Display Value Concentration / Flame Intensity
Testing Elements K, Na, Li, Ca, Ba
Channels 5
Display Value Concentration value / Energy
Testing Elements K, Na
Channels 2
Display Value Concentration / Flame Intensity