Manifold Vacuum Filtration Unit ADMFA-504

Manifold Vacuum Filtration Unit ADMFA-504

Manifold Vacuum Filtration Unit ADMFA-504 is designed with a capacity of 300 mL. It features a separate valve that enables filtering of either a single sample or multiple samples at the same time. The stainless-steel resists acid and alkali, ensuring efficient performance and easy operation. This unit is capable of functioning effectively in high-temperature environments.Our Manifold Vacuum Filtration Unit is ideal for the food and beverage industry.


Funnel Size 300 mL
Funnel SS316L
Support Screen SS316L
Pore Size 100 μm
Flask 1000 mL
Connection Stopper
Branch 3-branch
  • 3-branch
  • Benchtop design
  • Single adaptable hose
  • High-strength anodized aluminum clamp
  • Stainless steel base with integrated frit support

Our Manifold Vacuum Filtration Unit ADMFA-504 is ideal for continuous filtration, microbiological fluid removal, and particle analysis. It is suitable for filtration of biological solutions in the chemical industry, biochemical pharmacy, environmental protection, and food and beverage sectors.

Accessory

Quantity

300 mL Stainless Steel (SS316L) funnel

1 Pc

1000 mL glass collection bottle

1 Pc

Anodized aluminum spring clamp

1 Pc

Support frit and stainless steel (SS316L) base

1 Pc

One piece of hosepipe

1 Pc

Manifold Vacuum Filtration Unit ADMFA-504 | Funnel SS316L | Pore Size 100 μm
Manifold Vacuum Filtration Unit ADMFA-504 | 3-branch | Benchtop design

Frequently Asked Questions of Manifold Vacuum Filtration Unit ADMFA-504

1. What role does the support screen with an SS316L frame play in the Manifold Vacuum Filtration Unit ADMFA-504?

In this Manifold Vacuum Filtration Unit ADMFA-504 the support screen, constructed from SS316L stainless steel, offers a stable and corrosion-resistant foundation for the membrane filter during filtration. It provides uniform support to prevent membrane damage under vacuum pressure, ensuring accurate and efficient filtration performance in rigorous laboratory environments.

2. How is the Manifold Vacuum Filtration Unit ADMFA-504 operated?

To operate this Manifold Vacuum Filtration Unit ADMFA-504, first assemble and connect all components following the structure diagram, ensuring all parts are securely and tightly fitted. Position the membrane filter on the funnel and secure it using the spring clamp. After completing the setup, activate the vacuum pump and promptly open the valve. The vacuum will then draw the sample through the membrane, with the filtrate collected in the glass collection bottle.

3. What benefits does the one-piece hosepipe offer in the Manifold Vacuum Filtration Unit ADMFA-504?

The one-piece hosepipe in the Manifold Vacuum Filtration Unit ADMFA-504 provides a secure, airtight connection between the filtration unit and the vacuum source. Its seamless design reduces the risk of leaks, simplifies maintenance, and improves overall durability. Constructed from flexible, high-quality material, it delivers reliable long-term performance in demanding laboratory environments.

4. What are the materials used for the funnel and collection bottle in the Manifold Vacuum Filtration Unit ADMFA-504?

This Manifold Vacuum Filtration Unit ADMFA-504 features a funnel constructed from high-quality stainless steel, ensuring durability and resistance to corrosion. The collection bottle is made of glass, providing clear visibility of the filtrate and compatibility with a wide range of chemical solutions.

5. What is the purpose of the Manifold Vacuum Filtration Unit ADMFA-504?

Our Manifold Vacuum Filtration Unit ADMFA-504 is a three-branch stainless steel filtration system featuring a stopper-type frame. It is engineered for efficient and dependable filtration in a range of applications, including microbiological fluid removal, particle analysis, and the filtration of biological solutions across the chemical, pharmaceutical, environmental, and food industries.

6. What is a Manifold Vacuum Filtration Unit used for?

The Manifold Vacuum Filtration Unit is used to filter multiple liquid samples simultaneously under vacuum pressure, commonly in microbiology, water testing, and pharmaceutical labs. This setup increases throughput and consistency by allowing parallel sample processing. It is especially useful when testing identical parameters across several samples in quality control and analytical procedures.

7. Can each branch be operated independently in Manifold Vacuum Filtration Unit?

Yes, each branch in Manifold Vacuum Filtration Unit features its own stopcock or valve for selective filtration without interrupting the entire system. This allows users to run one or more filtrations as needed, improving workflow flexibility. It also helps conserve resources by isolating unused ports during partial operation.

Similar Products of Manifold Vacuum Filtration Unit

Funnel Size 300 mL
Funnel SS316L
Support Screen SS316L
Funnel Size 300 mL
Funnel Glass
Support Screen PTFE
Funnel Size 300 mL
Funnel SS316L
Support Screen SS316L
Funnel Size 300 mL
Funnel Glass
Support Screen PTFE

Vacuum Filtration Unit

Vacuum Filtration Unit ADFA-501
Funnel Volume:300 mL
Funnel Valve:Glass
Filter Membrane Pore Size:10 μm
Filtration Apparatus ADFA-503
Capacity:300 mL
Filter Size:10 µm
Receiving Bottle:1000 mL
Vacuum Filtration Unit ADFA-502
Funnel Volume:500 mL
Funnel Valve:Glass
Filter Membrane Pore Size:10 μm