Tissue Water Bath ADTWB-503

Tissue Water Bath ADTWB-503

Tissue Water Bath ADTWB-503 has a 2.5 L chamber, ideal for handling small to moderate lab procedures. It supports a broad heating range, enabling multiple thermal applications. Designed for low energy usage, it ensures optimal operation without excessive power demand. A removable power cable simplifies cleaning and upkeep. Tissue Water Bath is ideal in research labs to accurately warm liquid specimens during experiments, culturing, and analytical testing.


Capacity 2.5 L
Temperature Range RT to 75 °C
Power Consumption 400 W
Power Supply AC 110 V, 50/60 Hz
Internal Dimensions (D × H) 210 mm × 65 mm
External Dimensions (D × H) 270 mm × 210 mm
Packaging Dimensions (W × D × H) 340 × 350 × 180 mm
Gross Weight 4 kg
  • Non-stick interior
  • Glare reduction
  • Water evaporation
  • Fiberglass insulation
  • Glass lid

Tissue Water Bath ADTWB-503 are used in laboratories to accurately heat and maintain liquid samples, providing precise temperature control for experiments, incubation, and analytical testing.

Frequently Asked Questions of Tissue Water Bath ADTWB-503

1. What is the main function of the Tissue Water Bath ADTWB-503?

Tissue Water Bath ADTWB-503 is designed to precisely heat liquid samples is laboratory settings. It provides uniform temperature control for experimental consistency. Its versatility makes it suitable for applications such as culturing, incubation, and analytical testing. The system ensures dependable performance for various research and diagnostic tasks. It is a reliable tool for maintaining optimal conditions in critical experiments.

2. How does the non-stick interior of the Tissue Water Bath ADTWB-503 benefit laboratory work?

The non-stick interior minimizes residue buildup, making cleaning quick and effortless. It prevents sample contamination during repeated use. The smooth finish maintains the unit efficiency and operational lifespan. This ensures consistent performance over extended periods. Such a design feature greatly reduces downtime between experiments.

3. What role does glare reduction play in the Tissue Water Bath ADTWB-503 operation?

Glare reduction enhances visibility during sample observation. It prevents light reflection, allowing clear monitoring of the specimens. This feature is particularly useful when precision is required for delicate procedures. It reduces eye strain for the operator. Enhanced visibility supports accurate handling of sensitive samples.

4. How does the fiberglass insulation of the Tissue Water Bath ADTWB-503 improve performance?

Fiberglass insulation minimizes heat loss, improving thermal efficiency. It ensures stable internal temperatures for long durations. This contributes to reduced energy consumption during operation. The insulation enhances the unit durability. It provides reliable performance even during continuous laboratory use.

5. Why is the glass lid of the Tissue Water Bath ADTWB-503 important in laboratory use?

The glass lid retains heat while allowing visual inspection without opening the chamber. It prevents unnecessary heat fluctuations during experiments. This helps maintain consistent sample conditions. The lid protects the contents from external contaminants. Its transparent nature supports uninterrupted observation.

6. What are Tissue Water Baths?

Tissue Water Baths are laboratory equipment that maintain samples at precise and stable temperatures. They use controlled water heating to ensure consistent conditions. These units are essential for various labs processes. They help achieve reliable and reproducible results in tissue handling.

7. What are the applications of Tissue Water Baths?

Tissue Water Baths are widely used in histology and research laboratories. They help in floating paraffin sections and warming reagents efficiently. They are suitable for any process requiring accurate temperature control. Their use ensures consistency and reliability in sample preparation.

Similar Products of Tissue Water Bath

Temperature Range 30 to 90 °C, with three independent heating zones and automatic constant control
Corrugated Drying Slot Design Angled slots at 60° for easy slide insertion and efficient handling
Slide Capacity Holds up to 40 slides simultaneously
Temperature Range Ambient to 90 °C (constant adjusting)
Temperature Error ±2 °C
Ambient Temperature 0 to 40 °C

Digital Water Bath

Digital Water Bath  ADDW-502
Capacity:6 L
Type:2 holes
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-508
Volume:12 L
Type:4 holes
Temperature Range:5 to 100°C
Digital Water Bath ADDW-505
Capacity:22 L
Type:8 holes
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-512
Volume:33 L
Temperature Range:5 to 100°C
Temperature Resolution:1°C
Digital Water Bath ADDW-503
Capacity:10 L
Type:4 holes
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-509
Volume:18.6 L
Type:8 holes
Temperature Range:5 to 100°C
Digital Water Bath ADDW-504
Capacity:16 L
Type:6 holes
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-513
Number of Chambers:3
Volume:7.56 L
Temperature Range:5 to 99°C
Digital Water Bath ADDW-501
Capacity:3 L
Type:1 hole
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-511
Volume:10.5 L
Temperature Range:5 to 100°C
Temperature Resolution:1°C
Digital Water Bath ADDW-507
Volume:24.48 L
Type:8 holes
Temperature Range:5 to 100°C
Digital Water Bath ADDW-506
Volume:18.36 L
Type:6 holes
Temperature Range:5 to 100°C
Digital Water Bath ADDW-510
Volume:20.88 L
Type:8 holes
Temperature Range:5 to 100°C

Analog Water Bath

Analog Water Bath ADAW-502
Holes:4
Temperature Accuracy:± 0.1 °C
Speed Range:0 to 2400 Rpm
Analog Water Bath ADAW-506
Temperature Control Range:RT. +5 to 100℃
Temperature Set Range:0℃ to 100℃
Temperature Accuracy:±0.3℃
Analog Water Bath ADAW-503
Holes:6
Temperature Accuracy:± 0.1 °C
Speed Range:0 to 2400 Rpm
Analog Water Bath ADAW-504
Temperature Control Range:RT. +5 to 100℃
Temperature Set Range:0℃ to 100℃
Temperature Accuracy:±0.3℃
Analog Water Bath ADAW-501
Holes:2
Temperature Accuracy:± 0.1 °C
Speed Range:0 to 2400 Rpm
Analog Water Bath ADAW-505
Temperature Control Range:RT. +5 to 100℃
Temperature Set Range:0℃ to 100℃
Temperature Accuracy:±0.3℃

Electric Heated Oil Bath

Electric Heated Oil Bath ADOB-505
Volume:20 L
Heating Medium:Oil
Temperature Range:300°C
Electric Heated Oil Bath ADOB-504
Capacity:50 L
Temperature Range:300 °C
Accuracy:± 1 °C
Electric Heated Oil Bath ADOB-501
Capacity:10 L
Temperature Range:300 °C
Accuracy:± 1 °C
Electric Heated Oil Bath ADOB-507
Volume:50 L
Heating Medium:Oil
Temperature Range:300°C
Electric Heated Oil Bath ADOB-506
Volume:30 L
Heating Medium:Oil
Temperature Range:300°C
Electric Heated Oil Bath ADOB-503
Capacity:30 L
Temperature Range:300 °C
Accuracy:± 1 °C
Electric Heated Oil Bath ADOB-502
Capacity:20 L
Temperature Range:300 °C
Accuracy:± 1 °C

Laboratory Circulating Water Bath

Laboratory Circulating Water Bath ADLC-502
Capacity:5 L
Temperature Range:­20 °C
Accuracy:± 0.5 °C
Laboratory Circulating Water Bath ADLC-503
Capacity:10 L
Temperature Range:­10 °C
Accuracy:± 0.5 °C
Laboratory Circulating Water Bath ADLC-501
Capacity:5 L
Temperature Range:­10 °C
Accuracy:± 0.5 °C
Laboratory Circulating Water Bath ADLC-504
Capacity:10 L
Temperature Range:­20 °C
Accuracy:± 0.5 °C

Refrigerated Thermostat Bath

Refrigerated Thermostat Bath  ADRT-503
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-505
Temperature Range:-5 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-504
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-507
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-502
Temperature Range:-40 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.05 ° C
Refrigerated Thermostat Bath  ADRT-506
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-501
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C

Shaking Water Bath

Shaking Water Bath ADSW-503
Temperature Range:5 to 100°C
Oscillation Mode:Reciprocating
Rotation Rate:300 rpm
Shaking Water Bath ADSW-502
Temperature Range:5 to 100°C
Oscillation Mode:Orbital/Reciprocating
Rotation Rate:0 to 220 rpm (orbital) <br/> 0 to 300 rpm (reciprocating)
Shaking Water Bath ADSW-501
Temperature Range:5 to 100°C
Oscillation Mode:Orbital
Rotation Rate:0 to 220 rpm

Shaking Air Bath

Shaking Air Bath ADWA-502
Temperature Range:5 to 50°C
Oscillation Mode:Orbital/Reciprocating
Rotation Rate:0 to 220 rpm (orbital) <br/> 0 to 300 rpm (reciprocating)
Shaking Air Bath ADWA-503
Temperature Range:5 to 50°C
Oscillation Mode:Reciprocating
Rotation Rate:0 to 300 rpm
Shaking Air Bath ADWA-505
Temperature Range:5 to 65°C
Oscillation Mode:Orbital/Reciprocating
Rotation Rate:40 to 300 rpm
Shaking Air Bath ADWA-504
Temperature Range:5 to 65°C
Oscillation Mode:Orbital
Rotation Rate:40 to 300 rpm
Shaking Air Bath ADWA-501
Temperature Range:5 to 50°C
Oscillation Mode:Orbital
Rotation Rate:0 to 220 rpm
Shaking Air Bath ADWA-506
Temperature Range:5 to 65°C
Oscillation Mode:Reciprocating
Rotation Rate:40 to 300 rpm

Constant Temperature Water Bath

Constant Temperature Water Bath ADWB-503
Capacity:14.8 Liters
Temperature Range:RT +5℃ to 99℃
Temperature Control:0.1℃
Constant Temperature Water Bath ADWB – 501
Capacity:4.9 Liters
Temperature Range:RT +5℃ to 99℃
Temperature Control:0.1℃
Digital Water Bath Pot ADWB-507
Temperature Range:5 ° C to 100 ° C
Resolution:± 0.1 ° C
Power:0.5 Kw
Constant Temperature Water Bath ADWB-504
Capacity:19.8 Liters
Temperature Range:RT +5℃ to 99℃
Temperature Control:0.1℃
Digital Water Bath Pot ADWB-506
Temperature Range:5 ° C to 100 ° C
Resolution:± 0.1 ° C
Power:1.5 Kw
Digital Water Bath Pot ADWB-508
Temperature Range:5 ° C to 100 ° C
Resolution:± 0.1 ° C
Power:1 Kw
Constant Temperature Water Bath ADWB-502
Capacity:9.9 Liters
Temperature Range:RT +5℃ to 99℃
Temperature Control:0.1℃
Digital Water Bath Pot ADWB-505
Temperature Range:5 ° C to 100 ° C
Resolution:± 0.1 ° C
Power:1.5 Kw

Thermostatic Water Bath

Thermostatic Water Bath ADTB-503
Tank Capacity:2 L
Number of Tanks:3
Temperature Setting Range:0℃ to 100℃
Thermostatic Water Bath ADTB-502
Tank Capacity:2 L
Number of Tanks:2
Temperature Setting Range:0℃ to 100℃
Thermostatic Water Bath ADTB-501
Tank Capacity:2 L
Number of Tanks:1
Temperature Setting Range:0℃ to 100℃
Thermostatic Water Bath ADTB-504
Tank Capacity:5 L
Temperature Setting Range:0℃ to 100℃
Temperature Control Range:RT.+5℃ to 100℃