Thermostatic Water Bath ADTB-501 is a compact unit providing precise temperature control from room temp +5 °C to 100 °C. It features a stainless-steel inner tank with a unique sealing structure to prevent water leakage. Designed with safety features, it provides reliable operation throughout the process. This system is equipped with an independent drain on the side of the tank, enabling easy removal of sewage after cleaning. Our Thermostatic Water Bath is used to maintain precise thermal control for heating samples in laboratories.


Tank Capacity 2 L
Number of Tanks 1
Temperature Setting Range 0℃ to 100℃
Temperature Control Range RT. +5℃ to 100℃
Temperature Accuracy ≤ ± 0.3℃ at 37℃
Temperature Uniformity ≤ ± 0.3℃ at 37℃
Display Accuracy 0.1℃
Heating Time ≤ 30min (from 25℃ to 100℃)
Time Range 1min to 99h59min
Voltage AC110 V or 220 V, 50 / 60Hz
Working Area (W × D × H) 125 × 100 × 115 mm
Dimensions (W × D × H) 206 × 254 × 310 mm
Packaging Dimensions (W × D × H) 360 × 330 × 310 mm
Net Weight 2.2 kg
Gross Weight 6 kg
  • Digital LED display
  • Uniform heat distribution
  • Gable design lid
  • Easy Drainage Port
  • Microprocessor temperature regulation

Thermostatic Water Bath ADTB-501 is ideal for maintaining precise thermal conditions in biological, chemical, and clinical laboratories. It is commonly used for sample incubation, reagent warming, and temperature-sensitive experiments.

Frequently Asked Questions of Thermostatic Water Bath ADTB-501

1. How accurate is the temperature control on the Thermostatic Water Bath ADTB-501?

Thermostatic Water Bath ADTB-501 uses a microprocessor-based system that maintains highly precise temperature control with minimal fluctuations. It ensures uniform heating throughout the water bath for consistent experimental results. Temperature accuracy is typically within a tight range to meet laboratory standards.

2. What safety features does the Thermostatic Water Bath ADTB-501 include?

Thermostatic Water Bath ADTB-501 is equipped with overheat protection and a water level sensor to prevent dry running, which safeguards both the unit and samples. These features help avoid accidents and ensure reliable, long-term operation. The exterior housing also stays cool to the touch.

3. How easy is it to clean and maintain the Thermostatic Water Bath ADTB-501?

Thermostatic Water Bath ADTB-501 has a corrosion-resistant stainless steel tank. This resists staining and is easy to wipe clean. A side drainage port allows quick water removal for regular maintenance. The design minimizes leaks and simplifies routine cleaning procedures.

4. Can the Thermostatic Water Bath ADTB-501 run continuously for extended periods?

Thermostatic Water Bath ADTB-501 is designed for stable, continuous operation with precise temperature control. It features reliable microprocessor regulation and built-in safety systems to support long-duration use without overheating or malfunction. This makes it suitable for prolonged experiments.

5. What types of samples can be used in the Thermostatic Water Bath ADTB-501?

Thermostatic Water Bath ADTB-501 is compatible with a wide range of laboratory samples, including biological, chemical, and clinical specimens. Its uniform heating ensures that delicate samples are maintained at consistent temperatures without risk of damage. The stainless steel tank is resistant to corrosion from various solutions.

6. What are the purposes of Thermostatic Water Bath in laboratories?

Thermostatic Water Bath are used to heat samples under stable and controlled conditions. They ensure uniform heating, ideal for multiple incubations, reactions, and thermal tests. Such baths improve accuracy and reproducibility across different experiments. They are widely used in biology, chemistry, and medical laboratories.

7. How are Thermostatic Water Bath cleaned and maintained?

Thermostatic Water Bath should be turned off and unplugged before cleaning procedures. Mild detergents and soft cloths are recommended for cleaning the inner tanks. Water should be drained regularly using the provided outlets. Harsh chemicals and abrasive tools should be avoided to protect the surfaces.

8. What types of samples can be heated in Thermostatic Water Bath?

Thermostatic Water Bath are suitable for a wide variety of biological, chemical, and clinical samples. They can handle test tubes, flasks, or containers with sensitive materials. These systems provide consistent heat without direct contact with the samples. Users must ensure sample containers are heat-resistant and properly sealed.

Similar Products of Thermostatic Water Bath

Tank Capacity 5 L
Temperature Setting Range 0℃ to 100℃
Temperature Control Range RT.+5℃ to 100℃
Tank Capacity 2 L
Number of Tanks 2
Temperature Setting Range 0℃ to 100℃
Tank Capacity 2 L
Number of Tanks 3
Temperature Setting Range 0℃ to 100℃

Digital Water Bath

Digital Water Bath ADDW-512
Volume:33 L
Temperature Range:5 to 100°C
Temperature Resolution:1°C
Digital Water Bath ADDW-504
Capacity:16 L
Type:6 holes
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-503
Capacity:10 L
Type:4 holes
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-506
Volume:18.36 L
Type:6 holes
Temperature Range:5 to 100°C
Digital Water Bath ADDW-508
Volume:12 L
Type:4 holes
Temperature Range:5 to 100°C
Digital Water Bath ADDW-507
Volume:24.48 L
Type:8 holes
Temperature Range:5 to 100°C
Digital Water Bath ADDW-505
Capacity:22 L
Type:8 holes
Temperature Range:RT+5 to 99℃
Digital Water Bath  ADDW-502
Capacity:6 L
Type:2 holes
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-501
Capacity:3 L
Type:1 hole
Temperature Range:RT+5 to 99℃
Digital Water Bath ADDW-511
Volume:10.5 L
Temperature Range:5 to 100°C
Temperature Resolution:1°C
Digital Water Bath ADDW-509
Volume:18.6 L
Type:8 holes
Temperature Range:5 to 100°C
Digital Water Bath ADDW-513
Number of Chambers:3
Volume:7.56 L
Temperature Range:5 to 99°C
Digital Water Bath ADDW-510
Volume:20.88 L
Type:8 holes
Temperature Range:5 to 100°C

Analog Water Bath

Analog Water Bath ADAW-504
Temperature Control Range:RT. +5 to 100℃
Temperature Set Range:0℃ to 100℃
Temperature Accuracy:±0.3℃
Analog Water Bath ADAW-503
Holes:6
Temperature Accuracy:± 0.1 °C
Speed Range:0 to 2400 Rpm
Analog Water Bath ADAW-505
Temperature Control Range:RT. +5 to 100℃
Temperature Set Range:0℃ to 100℃
Temperature Accuracy:±0.3℃
Analog Water Bath ADAW-501
Holes:2
Temperature Accuracy:± 0.1 °C
Speed Range:0 to 2400 Rpm
Analog Water Bath ADAW-502
Holes:4
Temperature Accuracy:± 0.1 °C
Speed Range:0 to 2400 Rpm
Analog Water Bath ADAW-506
Temperature Control Range:RT. +5 to 100℃
Temperature Set Range:0℃ to 100℃
Temperature Accuracy:±0.3℃

Electric Heated Oil Bath

Electric Heated Oil Bath ADOB-507
Volume:50 L
Heating Medium:Oil
Temperature Range:300°C
Electric Heated Oil Bath ADOB-506
Volume:30 L
Heating Medium:Oil
Temperature Range:300°C
Electric Heated Oil Bath ADOB-505
Volume:20 L
Heating Medium:Oil
Temperature Range:300°C
Electric Heated Oil Bath ADOB-504
Capacity:50 L
Temperature Range:300 °C
Accuracy:± 1 °C
Electric Heated Oil Bath ADOB-501
Capacity:10 L
Temperature Range:300 °C
Accuracy:± 1 °C
Electric Heated Oil Bath ADOB-503
Capacity:30 L
Temperature Range:300 °C
Accuracy:± 1 °C
Electric Heated Oil Bath ADOB-502
Capacity:20 L
Temperature Range:300 °C
Accuracy:± 1 °C

Laboratory Circulating Water Bath

Laboratory Circulating Water Bath ADLC-501
Capacity:5 L
Temperature Range:­10 °C
Accuracy:± 0.5 °C
Laboratory Circulating Water Bath ADLC-502
Capacity:5 L
Temperature Range:­20 °C
Accuracy:± 0.5 °C
Laboratory Circulating Water Bath ADLC-504
Capacity:10 L
Temperature Range:­20 °C
Accuracy:± 0.5 °C
Laboratory Circulating Water Bath ADLC-503
Capacity:10 L
Temperature Range:­10 °C
Accuracy:± 0.5 °C

Refrigerated Thermostat Bath

Refrigerated Thermostat Bath  ADRT-503
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-507
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-506
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-504
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-501
Temperature Range:-20 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-505
Temperature Range:-5 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.02 ° C
Refrigerated Thermostat Bath  ADRT-502
Temperature Range:-40 ° C to 100 ° C
Resolution:0.01 ° C
Stability:± 0.005 ° C to ± 0.05 ° C

Shaking Water Bath

Shaking Water Bath ADSW-503
Temperature Range:5 to 100°C
Oscillation Mode:Reciprocating
Rotation Rate:300 rpm
Shaking Water Bath ADSW-501
Temperature Range:5 to 100°C
Oscillation Mode:Orbital
Rotation Rate:0 to 220 rpm
Shaking Water Bath ADSW-502
Temperature Range:5 to 100°C
Oscillation Mode:Orbital/Reciprocating
Rotation Rate:0 to 220 rpm (orbital) <br/> 0 to 300 rpm (reciprocating)

Shaking Air Bath

Shaking Air Bath ADWA-503
Temperature Range:5 to 50°C
Oscillation Mode:Reciprocating
Rotation Rate:0 to 300 rpm
Shaking Air Bath ADWA-504
Temperature Range:5 to 65°C
Oscillation Mode:Orbital
Rotation Rate:40 to 300 rpm
Shaking Air Bath ADWA-502
Temperature Range:5 to 50°C
Oscillation Mode:Orbital/Reciprocating
Rotation Rate:0 to 220 rpm (orbital) <br/> 0 to 300 rpm (reciprocating)
Shaking Air Bath ADWA-506
Temperature Range:5 to 65°C
Oscillation Mode:Reciprocating
Rotation Rate:40 to 300 rpm
Shaking Air Bath ADWA-501
Temperature Range:5 to 50°C
Oscillation Mode:Orbital
Rotation Rate:0 to 220 rpm
Shaking Air Bath ADWA-505
Temperature Range:5 to 65°C
Oscillation Mode:Orbital/Reciprocating
Rotation Rate:40 to 300 rpm

Constant Temperature Water Bath

Constant Temperature Water Bath ADWB-504
Capacity:19.8 Liters
Temperature Range:RT +5℃ to 99℃
Temperature Control:0.1℃
Constant Temperature Water Bath ADWB-502
Capacity:9.9 Liters
Temperature Range:RT +5℃ to 99℃
Temperature Control:0.1℃
Digital Water Bath Pot ADWB-506
Temperature Range:5 ° C to 100 ° C
Resolution:± 0.1 ° C
Power:1.5 Kw
Digital Water Bath Pot ADWB-508
Temperature Range:5 ° C to 100 ° C
Resolution:± 0.1 ° C
Power:1 Kw
Constant Temperature Water Bath ADWB-503
Capacity:14.8 Liters
Temperature Range:RT +5℃ to 99℃
Temperature Control:0.1℃
Digital Water Bath Pot ADWB-507
Temperature Range:5 ° C to 100 ° C
Resolution:± 0.1 ° C
Power:0.5 Kw
Constant Temperature Water Bath ADWB – 501
Capacity:4.9 Liters
Temperature Range:RT +5℃ to 99℃
Temperature Control:0.1℃
Digital Water Bath Pot ADWB-505
Temperature Range:5 ° C to 100 ° C
Resolution:± 0.1 ° C
Power:1.5 Kw

Tissue Water Bath

Tissue Water Bath ADTWB-502
Temperature Range:30 to 90 °C, with three independent heating zones and automatic constant control
Corrugated Drying Slot Design :Angled slots at 60° for easy slide insertion and efficient handling
Slide Capacity:Holds up to 40 slides simultaneously
Tissue Water Bath ADTWB-501
Temperature Range:Ambient to 90 °C (constant adjusting)
Temperature Error :±2 °C
Ambient Temperature :0 to 40 °C
Tissue Water Bath ADTWB-503
Capacity:2.5 L
Temperature Range :RT to 75 °C
Power Consumption :400 W