Vertical Laminar Air Flow Cabinet ADVL-509 comes with 1200×575×1360 mmof external dimension making it suitable for labs with limited space. This unit features a transparent sash for clear visibility. The pre-filter system traps larger particles to extend the life of the main HEPA filter. It allows airflow adjustment to suit specific procedures. Our Vertical Laminar Airflow Cabinet is used in labs, hospitals, and food processing to maintain sterile environments.
External Dimension (L×B×H) | 1200×575×1360 mm |
Internal Dimension (L×B×H) | 1190×530×400mm |
Surface Wind Speed | 0.5 m/h |
Frequency | 50 to 60 H |
Air Treatment | 230 m³/h |
Noise | 50 db |
Electric Current | 10 A |
Type of Filter | H14 |
Fan Power | 48 W to 110 W |
Clean Cabinet | MPPS test shows 99.995% filtration efficiency for particles ≥0.3 microns. |
Work Top | 1.25 mm stainless steel worktop; non-conductive and corrosion resistant. |
High-Efficiency Particle Filter | HEPA H14 filter ensures 99.995% efficiency for particles ≥0.3 µm. |
Pre particle Filter | 40% filtration efficiency for particles >0.3 µm. |
Power Supply | 110 to 240 V |
Our Vertical Laminar Airflow Cabinet ADVL-509 is used in forensic science, academic institutions and quality control testing to ensure a sterile and controlled environment for contamination-sensitive tasks.
1. What is the primary function of the Vertical Laminar Air Flow Cabinet ADVL-509?
The Vertical Laminar Air Flow Cabinet ADVL-509 provides a sterile working environment by delivering a continuous vertical flow of HEPA-filtered air over the work surface. This laminar flow helps protect samples and products from airborne contamination. It is commonly used in microbiology, pharmaceuticals, and electronics industries. The vertical airflow pushes particles downward and away from the work area. This ensures a clean zone for sensitive procedures.
2. Does the Vertical Laminar Air Flow Cabinet ADVL-509 offer HEPA filtration and what is its efficiency?
Yes, the Vertical Laminar Air Flow Cabinet ADVL-509 is equipped with a high-efficiency HEPA H14 filter. It ensures 99.995% filtration efficiency for particles 0.3 microns or larger. This level of filtration meets ISO Class 5 cleanliness standards. The filter effectively removes dust, aerosols, and microorganisms. It provides maximum protection for both the sample and working environment.
3. Is the Vertical Laminar Air Flow Cabinet ADVL-509 suitable for handling hazardous or biohazardous materials?
No, the Vertical Laminar Air Flow Cabinet ADVL-509 is not designed for handling hazardous or biohazardous materials. It only provides product protection, not user or environmental protection. For hazardous materials, a biosafety cabinet or fume hood should be used instead. This unit is ideal for sterile operations like media preparation or aseptic assembly. Always choose the right cabinet type based on your application’s risk level.
4. What are the key features of the Vertical Laminar Air Flow Cabinet ADVL-509 model?
The Vertical Laminar Air Flow Cabinet ADVL-509 features a stainless-steel work surface, HEPA filter, UV germicidal lamp, internal lighting, and low-noise blower system. Its vertical airflow design ensures uniform air velocity across the workspace. It includes a transparent front sash for visibility and user comfort. The cabinet is easy to clean and corrosion-resistant. These features make it suitable for cleanroom and laboratory environments.
5. How is the airflow in the Vertical Laminar Air Flow Cabinet ADVL-509 maintained and monitored?
The unit maintains a consistent vertical laminar airflow using an energy-efficient fan system. Airflow velocity is usually pre-set but may be adjustable depending on the model. It ensures constant pressure to sustain a sterile working environment. Some models may include a pressure gauge or airflow alarm system for monitoring. Regular maintenance and filter checks are essential to ensure optimal performance.
6. Why is unidirectional flow important in Vertical Laminar Airflow?
Unidirectional flow in Vertical Laminar Airflow ensures that air moves in a single straight path downward, sweeping away contaminants and preventing cross-contamination in the workspace.
External Dimension (L×B×H) | 1000×550×1600 mm |
Internal Dimension (L×B×H) | 950×500×460 mm |
Surface Wind Speed | 0.5 m/h |
USD 1,430.00
External Dimension (L×B×H) | 800×575×580 mm |
Internal Dimension (L×B×H) | 790×530×400 mm |
Surface Wind Speed | 0.5 m/h |
USD 510.00
External Dimension (L×B×H) | 1200×575×580 mm |
Internal Dimension (L×B×H) | 1190×530×400 mm |
Surface Wind Speed | 0.5 m/h |
USD 720.00
External Dimension (L×B×H) | 1200×550×1600 mm |
Internal Dimension (L×B×H) | 1150×500×460 mm |
Surface Wind Speed | 0.5 m/h |
USD 1,570.00
Velocity: | 0.3 to 0.6 m/s |
Half Peak Amplitude: | ≤ 3µm |
Number of Colonies: | ≤ 0.5 dish/hr |
Velocity: | 0.3 to 0.6 m/s |
Half Peak Amplitude: | ≤ 3µm |
Number of Colonies: | ≤ 0.5 dish/hr |
Velocity: | 0.3 to 0.6 m/s |
Half Peak Amplitude: | ≤ 3µm |
Number of Colonies: | ≤ 0.5 dish/hr |
Velocity: | 0.3 to 0.6 m/s |
Half Peak Amplitude: | ≤ 3µm |
Number of Colonies: | ≤ 0.5 dish/hr |
Internal Dimensions (W×D×H): | 910×480×570 mm |
Exterior Dimensions (W×D×H): | 910×790×1380 mm |
Airflow Direction: | Horizontal |
USD 1,350.00
Internal Dimensions (W×D×H): | 1570×480×570 mm |
Exterior Dimensions (W×D×H): | 1570×790×1380 mm |
Airflow Direction: | Horizontal |
USD 2,020.00