Automatic Colony Counter ADCCA-502

Automatic Colony Counter ADCCA-502

Automatic Colony Counter ADCCA-502 offers 12-megapixel high-performance camera for detailed imaging. It includes adjustable multi-colour LEDs and UV lamps for precise lighting and disinfection. The system supports plates of various sizes, accommodating small to large diameter samples easily. Multiple digital counting modes ensure fast and accurate results. They are ideal for microbiology and pharmaceutical laboratories; it efficiently automates colony counting.


Camera Model SONY CMOS 6300K; 12 Ultra-Fine HISPVP
Camera Resolution 12-megapixel high-performance camera
Lens Resolution 5MP high-resolution lens
Light Source (Visible) 3-Color LED, 288 units, adjustable colour intensity and temperature
Light Source (UV) 3 UV lamps with specific wavelength, 54 nm professional UV lamp
Dark Chamber Stainless steel with black mesh inside surface
UV Disinfection UV inner chamber
Sample Plate Size Maximum diameter 110mm
Range of Counting Circular, square, polygon
Counting Mode Digital adjustment of statistical sensitivity, fast statistics, accurate statistics, Trans-statistics, counting by click, counting back
Image Processing Original image restoration, Adhesion segmentation, Image labelling, Straight line measurement, Angle measurement, data storage, instrument calibration, automatic measurement of the whole plate
A.I System Colony Analyse, pre-installed
Control Panel Touch pad with light switch, intensity, UV control
Instrument Settings Common settings, advanced settings, data query, report generation
Network and Connection USB 3.0
Power Requirement AC 220V, 50Hz
External Dimensions (L×W×H) 360×475×445mm
Gross Weight (G.W.) 110 kg
  • Black mesh surface
  • Automatic measurement
  • High-resolution camera
  • Image processing
  • Adjustable LEDs

Automatic Colony Counter ADCCA-502 is ideal for microbiology and pharmaceutical labs, it automates colony counting to boost efficiency. This device ensures accurate results, helping researchers make faster decisions.

Frequently Asked Questions of Automatic Colony Counter ADCCA-502

1. How does Automatic Colony Counter ADCCA-502 improve colony counting accuracy?

Equipped with a 12MP high-performance camera and AI analysis, Automatic Colony Counter ADCCA-502 delivers precise colony counting. It minimizes human error and enhances accuracy, ensuring reliable results for research and quality control.

2. Is Automatic Colony Counter ADCCA-502 easy to operate?

Automatic Colony Counter ADCCA-502 features an intuitive touchpad control and USB 3.0 connectivity for easy operation and data transfer. Its user-friendly design helps lab technicians quickly adjust settings and manage data without technical hassles.

3. What types of lighting does Automatic Colony Counter ADCCA-502 use?

Using adjustable 3-color LEDs and UV lamps, Automatic Colony Counter ADCCA-502 provides optimal illumination and UV disinfection. This combination improves colony visibility and maintains a sterile environment during analysis.

4. What are the benefits of using the Automatic Colony Counter ADCCA-502 in labs?

Automatic Colony Counter ADCCA-502 automates colony counting to save time and reduce errors. It generates detailed reports and is ideal for microbiology and pharmaceutical labs, enhancing workflow efficiency and data accuracy.

5. What are the benefits of using the Automatic Colony Counter ADCCA-502 in labs?

Automatic Colony Counter ADCCA-502 automates colony counting to save time and reduce errors. It generates detailed reports and is ideal for microbiology and pharmaceutical labs, enhancing workflow efficiency and data accuracy.

6. What plate sizes can Automatic Colony Counter ADCCA-502 handle?

Automatic Colony Counter ADCCA-502 supports plates of various sizes up to 110mm diameter, accommodating small to large samples. This versatility allows labs to analyze different culture plates efficiently without needing multiple devices.

7. What is an Automatic Colony Counter?

An Automatic Colony Counter is a device that uses advanced imaging and software to quickly and accurately count microbial colonies on petri dishes. It reduces manual counting errors and speeds up analysis, providing reliable results for microbiology labs.

8. What types of plates can Automatic Colony Counter analyse?

Automatic Colony Counter supports various plate sizes and types, including standard petri dishes and different culture media. This versatility allows it to be used in many microbiology applications with different sample formats.

9. How does Automatic Colony Counter improve lab efficiency?

Automatic Colony Counter, it reduces manual errors and delivers consistent, precise results. The faster processing enables lab technicians to handle more samples in less time, enhancing productivity and workflow in microbiology and quality control labs.

Similar Products of Automatic Colony Counter

Camera Model SONY CMOS 6300K; 12 Ultra-Fine HISPVP
Camera Resolution 6.3-megapixel high-performance camera
Lens Resolution 3MP high-resolution lens

Manual Colony Counter

Manual Colony Counter ADMCC-501
Counting Capacity:0 to 9999
Magnification:3 to 6 times
Counting Plate Diameter:118mm
Manual Colony Counter ADMCC-502
Counting Capacity:0 to 999
Magnification:3 to 9 times
Counting Plate Diameter:115mm
Manual Colony Counter ADMCC-503
Counting Capacity:0 to 999
Magnification:3 to 9 times
Counting Plate Diameter:115mm