| Speed | 10 to 70 rpm |
| Maximum Load with clamps | 3 kg |
| Orbital Diameter | 10° |
| Operation Mode | Continuous |
| Shaking Mode | Rock shaking |
| Shell Guard Level | IP21 |
| Power Consumption | 50 W |
| Power Supply | DC 24V |
| Dimensions (W×D×H) | 345×308×108 mm |
Our Rocker Shaker ADRSH-501 is widely used for dying and decolorizing applications. It is an ideal unit for cell culture, antibody and vaccine production, as well as for hybridization, western blotting, and sample washing procedures.
Accessory | Dimension | Quantity |
Single platform | 280×260 mm | 1 Pc |
Double platform | 280×260×120 mm | 1 Pc |
1. What is the operation and shaking modes of the Rocker Shaker?
The Rocker Shaker operates in continuous mode, enabling long, uninterrupted mixing sessions. It utilizes a gentle rocking motion that ensures uniform agitation, making it ideal for cell cultures, suspensions, and general laboratory mixing applications.
2. What is the maximum load capacity of the Rocker Shaker with clamps?
This Rocker Shaker supports a maximum load of 3 kg when used with clamps, making it suitable for securely holding multiple flasks or vessels during operation. This capacity ensures stable performance even with heavier sample setups.
3. Does the Rocker Shaker come with interchangeable platforms?
Yes, our Rocker Shaker is equipped with interchangeable platforms, allowing compatibility with various vessels such as culture plates, flasks, and tubes for versatile laboratory use. This flexibility makes it easy to adapt the shaker for different experimental needs and sample volumes.
4. What does the IP21 shell guard level mean for the Rocker Shaker?
In this Rocker Shaker IP21 rating indicates that the orbital shaker’s shell guard protects against solid objects larger than 12.5 mm and vertical dripping water, providing reliable safety and durability in laboratory environments. This helps prevent damage from accidental spills or light moisture exposure.
5. What makes the Rocker Shaker’s rubber mat suitable for long-term use?
This Rocker Shaker features a durable rubber mat that is leakproof and resistant to corrosion, ensuring longevity and safe operation. This mat securely holds vessels in place during shaking to prevent spills. Its anti-corrosive properties protect against chemical damage, making it ideal for various laboratory applications.
6. What is a Rocker Shaker used for?
A Rocker Shaker is commonly used for gentle mixing applications such as staining, de-staining, western blots, hybridization, and cell culture. Its smooth rocking motion helps avoid damage to sensitive samples. It is widely used in molecular biology and clinical laboratories for uniform sample processing.
7. What types of containers can be used with the Rocker Shaker?
The Rocker Shakers platform accommodates a wide range of containers, including flasks, tubes, dishes, and culture plates. Anti-slip surfaces keep them securely in place during operation. This versatility makes rocker shakers suitable for many lab protocols. Optional attachments and racks can further customize the platform for specific container types.
8. How do I clean and maintain the Rocker Shaker?
The Rocker Shakers platform can be wiped down with a mild disinfectant. Avoid using harsh chemicals. The brushless motor requires no regular maintenance. Regularly check for any loose parts or debris to ensure smooth operation. Always unplug the unit before cleaning to ensure safety.
| Speed Range | 1 to 70 rpm |
| Maximum Load | 2.0 kg |
| Tilt Angle | 1 to 10 ° |
| Speed | 10 to 100 rpm |
| Maximum Load | 5.0 kg |
| Amplitude | 25mm, 10’, up and down |
| Speed: | 50 to 300 rpm |
| Orbital Diameter: | 10 mm |
| Maximum Load : | 3 kg |
| Speed Range: | 40 to 200 rpm |
| Maximum Load: | 1.2 kg |
| Orbit Diameter: | 20 mm |
| Speed Range: | 50 to 300 rpm |
| Orbital Diameter: | 10 mm |
| Timer Setting: | 1min to 99h59min |
| Speed Range: | 50 to 350 rpm |
| Orbital Diameter : | 10 mm |
| Timer Setting : | 1 min to 99 hr 59 min |
| Speed: | 40 to 200rpm |
| Maximum Load: | 5 kg |
| Orbit Diameter: | 20 mm |
| Speed: | 50 to 250 rpm |
| Orbital Diameter: | 20 mm |
| Maximum Load : | 2.5 kg |
| Speed Range: | 50 to 350 rpm |
| Orbital Diameter : | 20 mm |
| Timer Setting : | 1 min to 99 hr 59 min |
| Speed Range: | 50 to 350 rpm |
| Orbital Diameter : | 30 mm |
| Timer Setting : | 1 min to 99 hr 59 min |
| Speed: | 50 to 250 rpm |
| Maximum Load with clamps: | 3.5 kg |
| Orbital Diameter: | 20 mm |
| Speed: | 40 to 200 rpm |
| Maximum Load: | 5 kg |
| Orbit Diameter: | 20 mm |
| Speed: | 40 to 200 rpm |
| Maximum Load: | 5 kg |
| Orbital Diameter: | Linear 20 mm |
| Speed Range: | 50 to 250 rpm |
| Orbital Diameter: | 20 mm |
| Maximum Load: | 2.5 kg |
| Speed Range: | 200 to 1500 rpm |
| Amplitude: | 3 mm, horizontal rotation |
| Timer: | 1 min to 99 hr 59 min / 0: infinite time |
| Shaking Speed: | 200 to 2000 rpm |
| Sample Capacity: | 2 plates |
| Speed Step Value: | 10 rpm |
| Speed: | 100 to 1200 rpm |
| RPM Increment: | 100 rpm |
| Horizontal Gyration Amplitude: | 4 m |
| Speed: | 500 to 1200 rpm |
| RPM Increment: | 10 rpm |
| Horizontal Gyration Amplitude: | 3 mm |
| Temperature Control Range: | RT. +5℃ to 80℃ |
| Shaking Speed: | 200 to 1600 rpm |
| Temperature Accuracy: | ≤ ± 0.5℃ |
| Speed: | Brushless motor 100to1200rpm |
| RPM Increment: | 100 rpm |
| Horizontal Gyration Amplitude: | 4 mm |
| Speed: | 500 to 1200rpm |
| RPM Increment: | 10 rpm |
| Horizontal Gyration Amplitude: | 3 mm |
| Shaking Speed: | 200 to 1500 rpm |
| Sample Capacity: | 4 plates |
| Speed Step Value: | 10 rpm |
| Speed: | 40 to 200 rpm |
| Max Load: | 3 kg |
| Plate Size : | 320×320 mm |