| Speed | 10 to 100 rpm |
| Maximum Load | 5.0 kg |
| Amplitude | 25mm, 10’, up and down |
| Timer | 1m to 99h 59m/0: infinite time |
| Power Consumption | 45 W |
| Power Supply | AC100 to 230V, 50/60 HZ |
| Tray Size (W×D) | 300×240 mm |
| Dimensions (W×D×H) | 284×264×139 mm |
| Net Weight | 5.6 kg |
Our Rocker Shaker ADRSH-502 is ideal for biomolecular hybridization on strips, as well as for staining and destaining procedures in electrophoresis and homogenization.
Accessory | Dimension | Quantity |
Single platform | 280×260 mm | 1 Pc |
Double platform | 280×260×120 mm | 1 Pc |
1. What is the tray size of the Rocker Shaker?
The tray size of the Rocker Shaker is 300 × 240 mm. This spacious platform allows for accommodating a variety of labware such as culture dishes, flasks, and tubes. Its design ensures secure placement and efficient mixing during operation. The size is optimized for versatility in common laboratory applications.
2. What types of laboratory vessels are compatible with the Rocker Shaker?
This Rocker Shaker is compatible with various laboratory vessels, such as petri dishes, triangular flasks, and culture flasks. Its interchangeable platforms provide a secure fit for different shapes and sizes. This versatility ensures efficient mixing and agitation for a wide range of applications. It is ideal for cell culture, staining, and hybridization processes.
3. How does the Rocker Shaker’s user interface enhance operation?
Our Rocker Shaker features a user-friendly LCD display that makes operation straightforward and intuitive. The clear screen allows easy monitoring and adjustment of settings. This simplifies control of speed and time parameters for precise results. It’s designed to improve user experience and efficiency in the lab.
4. How do ball bearings improve the Rocker Shaker’s performance?
Ball bearings in the Rocker Shaker enhance the smoothness of motion, reducing friction during operation. This results in quieter, more efficient shaking cycles. They increase the reliability and longevity of the joints by minimizing wear and tear. Overall, ball bearings contribute to the unit’s durable and stable performance.
5. What are the features of the Rocker Shaker’s platforms?
This Rocker Shaker features stainless steel platforms equipped with wear-resistant mats that are easy to clean. These platforms are corrosion-resistant, ensuring long-lasting durability in laboratory environments. They are also designed to resist deformation, maintaining a stable surface during operation. This combination guarantees reliable performance and low maintenance.
6. What is a Rocker Shaker used for?
A Rocker Shaker is commonly used for gentle mixing applications such as staining, de-staining, western blots, hybridization, and cell culture. Its smooth rocking motion helps avoid damage to sensitive samples. It is widely used in molecular biology and clinical laboratories for uniform sample processing.
7. What types of containers can be used with the Rocker Shaker?
The Rocker Shakers platform accommodates a wide range of containers, including flasks, tubes, dishes, and culture plates. Anti-slip surfaces keep them securely in place during operation. This versatility makes rocker shakers suitable for many lab protocols. Optional attachments and racks can further customize the platform for specific container types.
8. How do I clean and maintain the Rocker Shaker?
The Rocker Shakers platform can be wiped down with a mild disinfectant. Avoid using harsh chemicals. The brushless motor requires no regular maintenance. Regularly check for any loose parts or debris to ensure smooth operation. Always unplug the unit before cleaning to ensure safety.
| Speed | 10 to 70 rpm |
| Maximum Load with clamps | 3 kg |
| Orbital Diameter | 10° |
| Speed Range | 1 to 70 rpm |
| Maximum Load | 2.0 kg |
| Tilt Angle | 1 to 10 ° |
| Speed: | 40 to 200rpm |
| Maximum Load: | 5 kg |
| Orbit Diameter: | 20 mm |
| Speed Range: | 50 to 300 rpm |
| Orbital Diameter: | 10 mm |
| Timer Setting: | 1min to 99h59min |
| Speed Range: | 50 to 350 rpm |
| Orbital Diameter : | 20 mm |
| Timer Setting : | 1 min to 99 hr 59 min |
| Speed: | 50 to 250 rpm |
| Orbital Diameter: | 20 mm |
| Maximum Load : | 2.5 kg |
| Speed Range: | 50 to 350 rpm |
| Orbital Diameter : | 30 mm |
| Timer Setting : | 1 min to 99 hr 59 min |
| Speed: | 40 to 200 rpm |
| Maximum Load: | 5 kg |
| Orbit Diameter: | 20 mm |
| Speed Range: | 50 to 350 rpm |
| Orbital Diameter : | 10 mm |
| Timer Setting : | 1 min to 99 hr 59 min |
| Speed: | 50 to 300 rpm |
| Orbital Diameter: | 10 mm |
| Maximum Load : | 3 kg |
| Speed Range: | 50 to 250 rpm |
| Orbital Diameter: | 20 mm |
| Maximum Load: | 2.5 kg |
| Speed: | 50 to 250 rpm |
| Maximum Load with clamps: | 3.5 kg |
| Orbital Diameter: | 20 mm |
| Speed: | 40 to 200 rpm |
| Maximum Load: | 5 kg |
| Orbital Diameter: | Linear 20 mm |
| Speed Range: | 40 to 200 rpm |
| Maximum Load: | 1.2 kg |
| Orbit Diameter: | 20 mm |
| Shaking Speed: | 200 to 2000 rpm |
| Sample Capacity: | 2 plates |
| Speed Step Value: | 10 rpm |
| Shaking Speed: | 200 to 1500 rpm |
| Sample Capacity: | 4 plates |
| Speed Step Value: | 10 rpm |
| Temperature Control Range: | RT. +5℃ to 80℃ |
| Shaking Speed: | 200 to 1600 rpm |
| Temperature Accuracy: | ≤ ± 0.5℃ |
| Speed: | 100 to 1200 rpm |
| RPM Increment: | 100 rpm |
| Horizontal Gyration Amplitude: | 4 m |
| Speed Range: | 200 to 1500 rpm |
| Amplitude: | 3 mm, horizontal rotation |
| Timer: | 1 min to 99 hr 59 min / 0: infinite time |
| Speed: | 500 to 1200rpm |
| RPM Increment: | 10 rpm |
| Horizontal Gyration Amplitude: | 3 mm |
| Speed: | 500 to 1200 rpm |
| RPM Increment: | 10 rpm |
| Horizontal Gyration Amplitude: | 3 mm |
| Speed: | Brushless motor 100to1200rpm |
| RPM Increment: | 100 rpm |
| Horizontal Gyration Amplitude: | 4 mm |
| Speed: | 40 to 200 rpm |
| Max Load: | 3 kg |
| Plate Size : | 320×320 mm |