Semi-Automatic Chemistry Analyzer ADSCA-502

Semi-Automatic Chemistry Analyzer ADSCA-502

Semi-Automatic Chemistry Analyzer ADSCA-502 supports a measuring volume range of 400 µl to 500 µl, ensuring optimal sample usage. It is equipped with excellent quality control mechanism and generous memory capacity. This system features with a flow cell system, allowing continuous sample analysis with minimal reagent use. It is designed with multiple incubating positions to support various tests simultaneously. This unit is ideal for performing routine biochemical tests in clinical labs to aid in disease diagnosis and patient monitoring.


Measuring System Measuring Range: 0 to 3.000 OD
Method: End Point, Fixed Time, Multistandard, Bichromatic and Immunoturbidimetry
Photometric linearity: ±2% (0 to 3.000 OD)
Photometric Accuracy: ±2% (0 to 3.000 OD)
Photometric System Light source: 6V/10W halogen lamp; Standby function
Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filters available
Wavelength Accuracy: ±2nm
Thermostatic Control Temperature: 25℃, 30℃, 37℃
Precision: ±0.1℃
Drift <0.005 OD/hr
Reading Cuvette Quartz flow through cell
Measuring Volume 400 µl to 500 µl
Incubating positions 20 Incubation positions
Test Menu T.BILI, r-GT/GGT, Ca, APOB-1/B, CHE, D.BILI, ALP/AKP, TG, CL, APOB, CREA, TP, UREA, CK, P, CK-MB, Mg, ALB, LDH, C, ASO, AFU, Lactic Acid, ALT/GPT, UA, α-HBDH, CO2, FMN, LP(α),AST/GOT, GLU, AMY, LDL-C, HDL-C, LA, TBA, ADA, HS-CRP,PA, Fe, Cu, Zn, C3, C4, IgG, IgA and drug, toxicity etc
Quality Control QC function with displaying and printing
Display Back illuminated color touch panel; LCD display
Storage Over 180 programs, 3000 test results
Interface RS-232, USB
Weight 8.0 kg
  • Quartz flow cell
  • Illuminated color touch display
  • Easy to use with low maintenance
  • Halogen lamp source
  • Minimal reagent usage

Semi-Automatic Chemistry Analyzer ADSCA-502 is used in clinical and research laboratories for accurate biochemical testing. It helps diagnose diseases and monitor patient health through reliable analysis of various biological samples.

Semi-Automatic Chemistry Analyzer ADSCA-502
Semi-Automatic Chemistry Analyzer ADSCA-502

Frequently Asked Questions of Semi-Automatic Chemistry Analyzer ADSCA-502

1. What is a Semi-Automatic Chemistry Analyzer ADSCA-502?

Semi-Automatic Chemistry Analyzer ADSCA-502 is a compact, easy-to-use device for precise biochemical testing. It uses a halogen lamp and covers a spectral range suitable for various assays. This system features a 7-inch color touchscreen for simple operation and real-time data display. It supports numerous programmable tests and stores a large volume of results. Connectivity options include a built-in printer, USB, and Ethernet for easy data transfer.

2. What types of tests does Semi-Automatic Chemistry Analyzer ADSCA-502 can perform?

Semi-Automatic Chemistry Analyzer ADSCA-502 can perform a wide range of biochemical tests. These include enzyme assays, electrolyte analysis, protein quantification, lipid profiling, liver and kidney function tests, and metabolic screenings. It supports both routine and specialized clinical chemistry tests. Such Analyzer is suitable for diverse diagnostic applications in clinical and research laboratories.

3. How accurate are the test results of Semi-Automatic Chemistry Analyzer ADSCA-502?

Semi-Automatic Chemistry Analyzer ADSCA-502 provides highly accurate test results through advanced photometric technology. Its stable halogen lamp and precise temperature control ensure consistent and reliable measurements. Built-in quality control functions help maintain accuracy over time. This makes the system dependable for routine clinical diagnostics. Users can trust the results for effective patient care and research.

4. What type of reading cuvette does the Semi-Automatic Chemistry Analyzer ADSCA-502 use?

Semi-Automatic Chemistry Analyzer ADSCA-502 uses a quartz flow-through cell as its reading cuvette. Quartz material provides excellent optical clarity and durability. This ensures accurate and consistent light transmission during measurements. This flow-through design allows continuous sample flow, improving testing efficiency. Overall, it enhances the precision and reliability of biochemical analysis.

5. How many incubation positions does the Semi-Automatic Chemistry Analyzer ADSCA-502 have?

Semi-Automatic Chemistry Analyzer ADSCA-502 is equipped with 20 incubation positions. This allows multiple samples to be processed simultaneously, improving lab efficiency. Each position maintains consistent temperature control for accurate reactions. The ample incubation capacity supports high-throughput testing needs. This feature enhances workflow and reduces turnaround time in busy laboratories.

6. What are Semi-Automatic Chemistry Analyzers?

Semi-Automatic Chemistry Analyzers are laboratory instrument used to perform biochemical tests on samples like blood or urine. Unlike fully automatic analyzers, they require some manual steps, such as sample preparation and reagent handling. These units improve testing accuracy and efficiency compared to manual methods. They are commonly used in clinics and research labs for reliable diagnostic support.

7. What is the working principle of Semi-Automatic Chemistry Analyzers?

Semi-Automatic Chemistry Analyzers work by mixing patient samples with specific reagents to trigger chemical reactions. They measure changes in light absorbance or color intensity to determine the concentration of substances in the sample. The operator manually loads samples and reagents but the machine controls incubation time and measurement. Results are displayed digitally and can be stored or printed.

8. What are the common applications of a Semi-Automatic Chemistry Analyzers?

Semi-Automatic Chemistry Analyzers are commonly used for biochemical testing in clinical labs, hospitals, and research facilities. They perform tests such as enzyme analysis, electrolyte measurement, protein quantification, and metabolic screening. These applications help to diagnose diseases, monitor patient health, and support medical research. Such systems are ideal for settings that require accurate, reliable testing without full automation. Their flexibility makes them suitable for a wide range of diagnostic purposes.

Similar Products of Semi-Automatic Chemistry Analyzer

Sample volume 0 to 3000µl (500µl recommended)
Light Source 6V, 10W halogen lamp
Wavelength filters 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 630 nm and 1 free position

Automatic Chemistry Analyzer

Automatic Chemistry Analyzer ADCA-501
Throughput:200 tests/hour
Sample Volume:2 to 70µl
Reagent Volume:20 to 350 µl