| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT. -5℃ to 100℃ |
| Speed Range | 200 to 3000 rpm |
| Temperature Accuracy | ≤ ± 0.3℃ |
| Temperature Uniformity | ≤ ± 0.3℃ |
| Orbit | 2 mm |
| Timing Range | 1sec to 99min59sec / 1min to 99h59min / infinite |
| Heating Time | ≤ 10 min (from 25℃ to 100℃) |
| Fan Cooling time | ≤ 12 min (from 100℃ to 37℃) |
| Display Accuracy | 0.1℃ |
| Heating Lid Temperature Setting Range | OFF / AUTO / 0℃ to 110℃ |
| Heating Lid Temperature Control Range | RT +5℃ to 110℃ |
| Heating Lid Temperature Control Mode | Automatic / Manual |
| Heating Lid Heating Time | ≤ 10 min (from 25℃ to 110℃) |
| Heating Lid Independent Temperature Control Function | Yes |
| Program Number | 10 programs (S0 to S9) |
| Multi-points Running | Yes (Maximum 5 points) |
| Multi Cycle | Yes (Maximum 99 times) |
| Auto Constant Temperature at End of Run | Yes |
| Auto Fan Function | Yes |
| Delay Heating Function | Yes |
| Fuse | 250V 3A Ф5×20 |
| Power Consumption | AC2 20V or 110V, 50 / 60Hz, 150W |
| Dimension (W × D × H) | 296 × 212 × 164 mm |
| Net Weight | 6.9 kg |
Heating Lid Thermo-Shaker ADHLT-501 is used for precise heating and controlled shaking of samples in molecular biology, biochemistry, and clinical research. It is used for sample incubation, catalytic reaction and preservation.
| Blocks | Description
| Speed Range | Quantity |
| Block 01 | 96 x 0.2ml PCR plate
| 200 to 2500 rpm | 1 Pc |
| Block 02 | 54 x 0.5 ml centrifuge tube
| 200 to 2500 rpm | 1 Pc |
| Block 03 | 35 x 1.5 ml centrifuge tube
| 200 to 2500 rpm | 1 Pc |
| Block 04 | 32 x 2.0 ml centrifuge tube
| 200 to 2500 rpm | 1 Pc |
| Block 05 | 15 ml x 0.5 ml + 20 ml x 1.5 ml centrifuge tube | 200 to 2500 rpm | 1 Pc |
1. Why is a Heating Lid Thermo-Shaker ADHLT-501 used for?
Heating Lid Thermo-Shaker ADHLT-501 is used for simultaneous heating and shaking of samples in laboratory settings, ensuring uniform temperature and mixing conditions. The heated lid prevents condensation on tube or plate lids, which helps maintain sample volume and concentration. It is especially useful in molecular biology, biochemistry, and clinical labs for processes like enzyme reactions, PCR preparation, and incubation.
2. How does the heating lid benefit the process in Heating Lid Thermo-Shaker ADHLT-501?
Heating lid in Heating Lid Thermo-Shaker ADHLT-501 provides consistent top heating that prevents condensation and evaporation during sample incubation. This helps maintain stable sample volumes and concentration throughout the process. By reducing moisture loss, it improves the accuracy and reliability of experimental results. Overall, the heating lid ensures better sample integrity and reproducibility.
3. Does the Heating Lid Thermo-Shaker ADHLT-501 include safety features?
Heating Lid Thermo-Shaker ADHLT-501 includes multiple safety features such as over-temperature protection to prevent overheating and automatic resume function after power interruptions. These features ensure reliable and safe operation during long experiments. Additionally, built-in alarms and temperature calibration options help maintain precise control.
4. How is temperature controlled in the Heating Lid Thermo-Shaker ADHLT-501?
Heating Lid Thermo-Shaker ADHLT-501 is controlled using a precise PID that continuously monitors and adjusts heating to maintain stable conditions. This intelligent control minimizes temperature fluctuations, ensuring consistent sample processing. It allows rapid heating while preventing overheating. The result is accurate and reliable temperature regulation throughout the experiment.
5. Is the Heating Lid Thermo-Shaker ADHLT-501 easy to operate?
Heating Lid Thermo-Shaker ADHLT-501 is designed with a user-friendly interface that makes operation simple and intuitive. The clear LCD display allows easy programming and real-time monitoring of temperature and shaking speed. Controls are straightforward, enabling quick adjustments to suit different experiments. This ease of use helps improve efficiency and reduces the chance of user errors.
6. What is a Thermo-Shaker?
A Thermo-Shaker is a laboratory device that combines precise temperature control with orbital shaking for effective sample mixing. It is ideal for applications requiring consistent heating and agitation, such as enzyme reactions and DNA extraction. The device enhances reproducibility and efficiency in a wide range of molecular biology and clinical protocols.
7. What safety features are included in Thermo-Shaker?
Typical safety features include in Thermo-Shaker is over-temperature protection, auto stop on error, and lid sensors. The automatic shutoff after inactivity and alarms for temperature or speed deviations. These features help protect both the user and the samples, ensuring reliable and safe operation.
8. How do I clean and maintain a Thermo-Shaker?
To clean and maintain a Thermo-Shaker use a soft cloth with mild detergent; avoid abrasive cleaners. Ensure the device is unplugged before cleaning and allow it to cool down completely. Periodically check for wear on moving parts and replace components as recommended to ensure optimal performance.