| Volume | 50 L |
| Maximum Working Temperature | 135°C to 139°C |
| Maximum Working Pressure | 0.22 to 0.25 MPa |
| Timer Range | 4 to 120 min |
| Number of Baskets | 2 Pc |
| Power Consumption | 3.2 kW |
| Power Supply | 220±10 V, 50±2 Hz |
| Basket Dimensions [W×D×H] | Ø360×230 mm |
| Internal Dimensions [W×D×H] | Ø400×630 mm |
| Housing Dimensions [W×D×H] | 485×485×1120 mm |
| Package Dimensions [W×D×H] | 610×610×1290 mm |
| Net Weight | 68 kg |
| Gross Weight | 82 kg |
Our Vertical Autoclave ADVA-529 is used in medical, microbiology and field research settings to sterilize equipment and materials conveniently and efficiently.
1. Can glassware and liquids be sterilized in a Vertical Autoclave?
Yes, a Vertical Autoclave can sterilize both glassware and liquids, but proper settings and precautions must be used to prevent breakage or spillage.
2. What safety precautions should be taken while operating a Vertical Autoclave?
When using a Vertical Autoclave, always wear protective gear, ensure the lid is locked properly, release pressure before opening, and never overload the chamber.
3. What is the power requirement for a Vertical Autoclave?
A Vertical Autoclave usually requires a single-phase or three-phase power supply, with power ratings typically between 2 kW to 9 kW, based on capacity.
4. What is a Vertical Autoclave and how does it work?
A Vertical Autoclave is a sterilization device that uses steam under pressure to sterilize equipment, media, and laboratory tools. It works by heating water to produce steam, which destroys bacteria, viruses, and other microorganisms.
5. What safety features are included in a Vertical Autoclave?
A Vertical Autoclave includes safety features like pressure release valves, temperature cut-offs, door interlocks, and alarms. These systems prevent accidental opening or overheating in the Vertical Autoclave. Built-in sensors ensure the unit shuts off in case of any malfunction.
6. Can a Vertical Autoclave be used for medical waste?
A Vertical Autoclave can be used to sterilize soft medical waste like gauze, gloves, and cloth items. However, a Vertical Autoclave may not be ideal for large volumes of waste or sharp objects. Special medical waste autoclaves are recommended for such loads.
| Chamber Volume | 150L φ (510×740) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Chamber Volume | 50L φ (340×550) mm |
| Working Pressure | 0.1 to 0.22MPa |
| Working Temperature | 120 to 134℃ |
| Chamber Volume | 50L(φ340×550) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Volume | 110 L |
| Sterilization Temperature | 105 to 135°C |
| Temperature Fluctuation | ±1°C |
| Volume: | 280 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 280 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Sterilizing Chamber Volume: | 200 L φ (515×1000mm) |
| Working Pressure: | 0.22Mpa |
| Working Temperature: | 134ºC |
| Sterilizing chamber volume: | 150 L φ (440×1000mm) |
| working pressure: | 0.22Mpa |
| Working temperature: | 134ºC |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105°C to 135°C |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 24L (280×390) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Temperature Adjust Range: | 105℃ to 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Chamber Volume: | 12L (240×200) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L 80×260 mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 24L (280 × 390) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature : | 126℃ |
| Chamber Volume: | 18L (280 × 260) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 20L φ (250×420) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 24L φ (250×520) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 35L φ (300×500) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 24L φ (270×410) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 16L φ (250×360) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 50L φ (340×550) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |