Horizontal Autoclave ADHA-509

Horizontal Autoclave ADHA-509

Horizontal Autoclave ADHA-509 is a horizontal autoclave sterilizer with a 100 L stainless steel chamber that works at 134 C and 0.22 MPa. This horizontal autoclave machine controls the sterilizing process automatically, and multiple pulsating vacuum exhaust steps handle packed, unpacked, hollow and porous loads. As a horizontal steam sterilizer, it has a built-in steam generator and a movable sterilization plate. The double-layer chamber with jacket dries the load deeply, a printer records the whole cycle, and the Bowie & Dick test function checks steam penetration. Over temperature, over pressure, low water level and over current protection, a safety valve, and a door safety interlock with alarm and pressure lock keep the cycle safe. The manual sealing door of this horizontal pressure steam sterilizer has two-stage self-locking and comes as a single door, with a double door as an option.


Sterilizing chamber volume 100 L (diameter 440 x 670 mm)
Working pressure 0.22 MPa
Working temperature 134 C
Temperature adjust range 115 to 134 C
Time for sterilization 0 to 99 min
Heat average within 2 C
Vacuum limit -0.08 MPa
Power 10 kW, 380 V, 50 Hz
Dimensions 1400 x 660 x 1640 mm
Exterior package dimensions 1560 x 920 x 1820 mm
Time for drying 0 to 99 min
Net Weight 340 kg
Gross Weight 430 kg

Primary Functions:
– Surgical instrument sterilization
– Laboratory ware sterilization
– Pharmaceutical material sterilization
Application:
– Hospitals
– Pharmaceutical units
– Chemical, food and research laboratories

Similar Products of Horizontal Autoclave

Sterilizing chamber volume 150 L φ (440×1000mm)
working pressure 0.22Mpa
Working temperature 134ºC
Sterilizing Chamber Volume 200 L φ (515×1000mm)
Working Pressure 0.22Mpa
Working Temperature 134ºC
Volume 280 L
Door Structure spoke
Temperature Range 105 to 135°C
Volume 360 L
Door Structure spoke
Temperature Range 105 to 135°C

Portable Autoclave

Portable Autoclave ADPA-503
Chamber Volume:18L (280 × 260) mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature:126℃
Portable Autoclave ADPA-509
Chamber Volume:24L (280×390) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-504
Chamber Volume:24L (280 × 390) mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature :126℃
Portable Autoclave ADPA-502
Sterilizing Volume:18L 80×260 mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature:126℃
Portable Autoclave ADPA-508
Chamber Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-507
Chamber Volume:18 L (240×200) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-506
Sterilizing volume:18L, φ280×260 mm
Working pressure:0.14–0.16 MPa
Working temperature:126 °C
Portable Autoclave ADPA-505
Working Pressure:0.14 to 0.16MPa
Working Temperature:126 ºC
Temperature Adjust Range:105℃ to 126℃
Portable Autoclave ADPA-501
Sterilizing Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16MPa
Working Temperature:126℃

Vertical Autoclave

Vertical Autoclave ADVA-522
Chamber Volume:50L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-531
Volume:100 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa
Vertical Autoclave ADVA-527
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-503
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-507
Chamber Volume:35L φ(318×450) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-502
Chamber Volume:50L(φ340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-536
Volume:90 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-508
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-505
Chamber Volume:120L(φ480×660) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-526
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-509
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-517
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-511
Chamber Volume:120L φ (480×660) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-519
Chamber Volume:75L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-525
Chamber Volume:50L φ (340×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-514
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-537
Capacity:60 L
Chamber Size:Φ 350 x 550 mm
Basket Size:330 x 190 (× 2)
Vertical Autoclave ADVA-529
Volume:50 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa
Vertical Autoclave ADVA-513
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-518
Chamber Volume:50 L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-524
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-501
Chamber Volume:35Lφ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-515
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-533
Volume:85 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-528
Volume:29 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa
Vertical Autoclave ADVA-516
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.14MPa
Working Temperature:126℃
Vertical Autoclave ADVA-532
Volume:60 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-520
Chamber Volume:100 L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-534
Volume:110 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-535
Volume:65 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-512
Chamber Volume:100L φ (510×740) mm
Working Pressure 0.1 to 0.22MPa:0.1 to 0.22MPa
Working Temperature 120 to 134℃:120 to 134℃
Vertical Autoclave ADVA-523
Chamber Volume:75L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-504
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22Mpa
Working Temperature:134℃
Vertical Autoclave ADVA-510
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-530
Volume:75 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa
Vertical Autoclave ADVA-506
Chamber Volume:150L φ (510×740) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-521
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃

Benchtop Autoclave

Benchtop Autoclave ADBA-506
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-502
Chamber Volume:24L φ (270×410) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-501
Chamber Volume:16L φ (250×360) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-503
Chamber Volume:20L φ (250×420) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-505
Chamber Volume:35L φ (300×500) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-504
Sterilizing volume:24 L (φ250 × 520 mm)
Maximum working pressure:0.22 MPa
Maximum working temperature:134 °C