| Chamber Volume | 75L φ (318×450) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Maximum Working Pressure | 0.23Mpa |
| Heat Average | ≤±1℃ |
| Timer Scope | 0 to 99min or 0 to 99hr 59min |
| Temperature Scope | 0 to 134℃ |
| Power Consumption | 4.5 KW |
| Power Supply | AC220V. 50Hz |
| Overall Dimension (L×B×H) | 690×470×1140 mm |
| Transport Dimension (L×B×H) | 760×550×1290 mm |
| Gross Weight | 120 Kg |
| Net Weight | 98 Kg |
Our Vertical Autoclave ADVA-523 is used in labs, research centers, and industrial sector for sterilizing instruments, media, and waste, ensuring safe conditions.
1. What is a vertical autoclave and how does it work?
A vertical autoclave is a cylindrical sterilization device designed to use pressurized steam to eliminate bacteria, viruses, fungi, and spores from equipment and materials. It works by heating water to produce steam, which builds pressure within a sealed chamber. The high temperature and pressure effectively sterilize items placed inside. These autoclaves are loaded from the top, making them space-efficient for small labs and clinics. They're ideal for laboratories, hospitals, and research institutions.
2. What are the typical applications of a vertical autoclave?
Vertical autoclave is widely used for sterilizing glassware, media, instruments, and laboratory waste. Common applications include microbiology, pharmaceutical production, food testing labs, and hospital surgical units. It is essential for preventing contamination and ensuring safe reuse of lab and clinical equipment. It is also used to prepare culture media. Its versatility makes them a go-to sterilization tool across scientific fields.
3. What materials can be sterilized in a vertical autoclave?
Vertical autoclave can sterilize glassware, metal instruments, fabric, rubber, and certain types of plastic. Liquids such as culture media or laboratory reagents can also be sterilized if the autoclave has a liquid cycle. Items must be autoclavable, meaning they can withstand high temperature and pressure. Materials with low melting points or sealed containers that may explode should be avoided. Always follow manufacturer guidelines for safe sterilization.
4. What are the standard temperature and pressure settings for vertical autoclave sterilization?
The most common sterilization settings are 121°C at 15 psi pressure for 15–30 minutes. Some models allow higher settings, such as 134°C at 30 psi, for faster sterilization. The time, temperature, and pressure can vary based on the load type and volume. Liquid cycles typically require lower pressure and longer holding times. Consistent monitoring ensures effective sterilization and equipment safety.
5. How long does a typical sterilization cycle take in a vertical autoclave?
A typical cycle lasts between 30 to 60 minutes, including heating, sterilization, and cooling phases. The sterilization (holding) phase alone is usually 15–30 minutes at 121°C. Heavier or denser loads take longer to heat and cool. Liquid loads often require extended time to avoid boil-over. Cycle duration can be adjusted based on the load type.
6. What is a Vertical Autoclave and how does it work?
A Vertical Autoclave is a sterilization device that uses steam under pressure to sterilize equipment, media, and laboratory tools. It works by heating water to produce steam, which destroys bacteria, viruses, and other microorganisms.
7. What safety features are included in a Vertical Autoclave?
A Vertical Autoclave includes safety features like pressure release valves, temperature cut-offs, door interlocks, and alarms. These systems prevent accidental opening or overheating in the Vertical Autoclave. Built-in sensors ensure the unit shuts off in case of any malfunction.
8. Can a Vertical Autoclave be used for medical waste?
A Vertical Autoclave can be used to sterilize soft medical waste like gauze, gloves, and cloth items. However, a Vertical Autoclave may not be ideal for large volumes of waste or sharp objects. Special medical waste autoclaves are recommended for such loads.
| Chamber Volume | 100 L φ (318×450) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Chamber Volume | 150L φ (510×740) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Chamber Volume | 100L φ (440×650) mm |
| Working Pressure | 0.14MPa |
| Working Temperature | 126℃ |
| Volume | 110 L |
| Sterilization Temperature | 105 to 135°C |
| Temperature Fluctuation | ±1°C |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105°C to 135°C |
| Volume: | 280 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Sterilizing Chamber Volume: | 200 L φ (515×1000mm) |
| Working Pressure: | 0.22Mpa |
| Working Temperature: | 134ºC |
| Sterilizing chamber volume: | 150 L φ (440×1000mm) |
| working pressure: | 0.22Mpa |
| Working temperature: | 134ºC |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 280 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Chamber Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Temperature Adjust Range: | 105℃ to 126℃ |
| Chamber Volume: | 24L (280 × 390) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature : | 126℃ |
| Chamber Volume: | 18L (280 × 260) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 24L (280×390) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 12L (240×200) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L 80×260 mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Chamber Volume: | 24L φ (250×520) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 50L φ (340×550) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 16L φ (250×360) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 35L φ (300×500) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 20L φ (250×420) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 24L φ (270×410) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |