Horizontal Autoclave ADHA-504

Horizontal Autoclave ADHA-504

Advalab Horizontal Autoclave ADHA-504 offers a large capacity of 280 L, allowing it to accommodate a variety of items. Our unit has high power consumption and working on a standard electrical power supply. The equipment operates within a temperature range of 105°C to 135°C for reliable performance. It features a steam generator and water pump for automatic water addition, ensuring efficient operation. These are used in research labs to sterilize glassware, media, and samples requiring high temperatures.

Volume 280 L
Door Structure spoke
Temperature Range 105 to 135°C
Power Consumption 12.5 kW
Power Supply 380 V, 50 Hz
Internal Dimensions (W×D×H) Ø600×1050 mm
Housing Dimensions (W×D×H) 1000×1515×1803 mm
Package Dimensions (W×D×H) 1600×1000×2000 mm
Net Weight 600 kg
Gross Weight 650 kg
  • Touch screen display
  • Event and time recording
  • USB data backup
  • Adjustable exhaust settings
  • Low water level protection
  • Easy to operate

Our Horizontal Autoclave ADHA-504 is used in research laboratories and pharmaceutical industries to sterilize agar plates, Petri dishes, and tools, ensuring contamination prevention.

  1. stainless steel housing 

Frequently Asked Questions of Horizontal Autoclave ADHA-504

1. What are the environmental impacts of using a Horizontal Autoclave?

Horizontal Autoclaves use energy and water, which can have environmental impacts if not managed properly. However, modern autoclaves are designed with energy-saving features and water-efficient systems to minimize these effects. Some models have eco-friendly cycles that reduce both energy consumption and water usage.

2. What is the typical lifespan of a Horizontal Autoclave?

The typical lifespan of a Horizontal Autoclave is between 10 to 20 years, depending on factors like the quality of the autoclave, frequency of use, and maintenance. Regular maintenance and proper usage can help extend the autoclave's lifespan.

3. Can I use a Horizontal Autoclave for sterilizing food?

Yes, Horizontal Autoclaves can be used for food sterilization, especially in the food processing industry for products like canned foods, beverages, or medical food items. Sterilizing food ensures the elimination of pathogens and extends the shelf life of the products. The process must be carefully controlled to prevent food quality degradation.

4. What types of racks or baskets are best for loading items into a Horizontal Autoclave?

The best racks or baskets for loading items into a Horizontal Autoclave are made of materials that can withstand high temperatures, such as stainless steel. They should be designed to allow for proper steam circulation between items to ensure efficient sterilization. Use appropriate racks that match the autoclave's capacity and are easy to load and unload.

5. How often should the seals of a Horizontal Autoclave be replaced?

The seals in a Horizontal Autoclave should be checked regularly for wear and tear. Typically, they should be replaced every 6 to 12 months or sooner if any cracks or damage are noticed. Worn-out seals can lead to steam leakage, affecting the sterilization process.

6. Do Horizontal Autoclaves require special installation?

Yes, Horizontal Autoclaves require professional installation due to their high-pressure steam operation and need for proper plumbing and electrical connections. It’s important to follow the manufacturer's installation guidelines and ensure the autoclave is installed in a well-ventilated area with easy access to water and drainage systems.

Similar Products of Horizontal Autoclave

Volume 280 L
Door Structure spoke
Temperature Range 105 to 135°C
Volume 360 L
Door Structure spoke
Temperature Range 105 to 135°C
Sterilizing chamber volume 150 L φ (440×1000mm)
working pressure 0.22Mpa
Working temperature 134ºC
Volume 360 L
Door Structure spoke
Temperature Range 105 to 135°C

Portable Autoclave

Portable Autoclave ADPA-501
Sterilizing Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16MPa
Working Temperature:126℃
Portable Autoclave ADPA-507
Chamber Volume:12L (240×200) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-505
Working Pressure:0.14 to 0.16MPa
Working Temperature:126 ºC
Temperature Adjust Range:105℃ to 126℃
Portable Autoclave ADPA-502
Sterilizing Volume:18L 80×260 mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature:126℃
Portable Autoclave ADPA-506
Sterilizing Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16MPa
Working Temperature:126 ºC
Portable Autoclave ADPA-508
Chamber Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-509
Chamber Volume:24L (280×390) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-503
Chamber Volume:18L (280 × 260) mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature:126℃
Portable Autoclave ADPA-504
Chamber Volume:24L (280 × 390) mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature :126℃

Vertical Autoclave

Vertical Autoclave ADVA-513
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-525
Chamber Volume:50L φ (340×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-512
Chamber Volume:100L φ (510×740) mm
Working Pressure 0.1 to 0.22MPa:0.1 to 0.22MPa
Working Temperature 120 to 134℃:120 to 134℃
Vertical Autoclave ADVA-507
Chamber Volume:35L φ(318×450) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-522
Chamber Volume:50L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-518
Chamber Volume:50 L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-511
Chamber Volume:120L φ (480×660) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-504
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22Mpa
Working Temperature:134℃
Vertical Autoclave ADVA-514
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-508
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-510
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-517
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-527
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-515
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-505
Chamber Volume:120L(φ480×660) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-516
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.14MPa
Working Temperature:126℃
Vertical Autoclave ADVA-506
Chamber Volume:150L φ (510×740) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-509
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-519
Chamber Volume:75L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-521
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-520
Chamber Volume:100 L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-523
Chamber Volume:75L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-501
Chamber Volume:35Lφ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-503
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-526
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-502
Chamber Volume:50L(φ340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-524
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃

Benchtop Autoclave

Benchtop Autoclave ADBA-506
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-505
Chamber Volume:35L φ (300×500) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-502
Chamber Volume:24L φ (270×410) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-504
Chamber Volume:24L φ (250×520) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-501
Chamber Volume:16L φ (250×360) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-503
Chamber Volume:20L φ (250×420) mm
Working Pressure:0.22MPa
Working Temperature:134℃