Benchtop Autoclave ADBA-506

Benchtop Autoclave ADBA-506

Benchtop Autoclave ADBA-506 operates at 0.22MPa of working pressure to efficiently sterilize medical instruments and materials. It is available in different capacities to accommodate various load sizes. This unit comes with a corrosion-resistant construction for enhanced durability and longevity. Provides real-time monitoring of pressure levels for safe operation. Our Benchtop Autoclave is used in Labs, pharmaceutical and food processing to sterilize instruments and glassware, ensuring hygiene.

Chamber Volume 50L φ (340×550) mm
Working Pressure 0.22MPa
Working Temperature 134℃
Adjustment of temperature 105º to 134℃
Heat Average ≤±1℃
Timer Scope 0 to 99Min
Power Consumption 2.7 KW
Power Supply AC220V. 50Hz
Sterilizing Plate (L×B×H) 500 ×250 × 30 mm (4piece)
Dimension (L×B×H) 770 × 600 × 540 mm
Package Dimension (L×B×H) 880× 730 × 700 mm
Gross Weight 105 Kg
Net Weight 86 Kg
  • Stainless steel structure
  • Water level indicator
  • Fast sterilization cycle
  • Energy-saving operation
  • Portable carry handles

Our Benchtop Autoclave ADBA-506 is used across various fields such as healthcare for sterilizing surgical tools, laboratories for decontaminating glassware and media and in research for ensuring sterile environments and materials.

Frequently Asked Questions of Benchtop Autoclave ADBA-506

1. What is a benchtop autoclave used for?

A benchtop autoclave is primarily used for sterilizing medical instruments, laboratory equipment, and materials in smaller settings like clinics, dental offices, and research labs. It uses high-pressure saturated steam to kill bacteria, viruses, fungi, and spores. This ensures that all tools are safe for reuse without any risk of infection. Benchtop autoclaves are valued for their compact size and ease of operation.

2. How to operate a benchtop autoclave?

Operating a benchtop autoclave typically involves loading the items properly, selecting the correct sterilization cycle, and starting the machine. Items must be cleaned first and arranged to allow steam to circulate around them. The user then chooses the time, temperature, and pressure settings based on the material type. After the cycle completes, the autoclave needs to cool down before the items are safely removed.

3. How often should a benchtop autoclave be maintained?

Routine maintenance should be done daily, weekly, and annually depending on usage frequency. Daily tasks include wiping down the chamber and checking gaskets for wear. Weekly maintenance often involves deeper cleaning, draining, and replacing water. Annual servicing by a professional technician ensures all parts, sensors, and pressure systems function safely and correctly. Regular maintenance extends the autoclave’s life and guarantees consistent sterilization performance.

4. What materials can be sterilized in a benchtop autoclave?

Benchtop Autoclave can sterilize metal instruments, certain plastics, glassware, and textiles like surgical drapes. Items must be labeled as "autoclavable" to withstand high heat and pressure. Some delicate items or electronics are not suitable unless specially designed for autoclave use. Proper packaging, like sterilization pouches or wraps, should be used to maintain sterility after the cycle.

5. How long does a benchtop autoclave cycle take?

The duration of a sterilization cycle in a benchtop autoclave typically ranges from 20 minutes to over an hour, depending on the selected program. Faster cycles are often available for unwrapped or lightly loaded items. Heavier loads, wrapped instruments, or complex sterilization processes like drying phases require more time. Preheating, air removal, and cooling periods also add to the total cycle time. Always consult the machine’s manual to choose the correct cycle for your load.

Similar Products of Benchtop Autoclave

Chamber Volume 20L φ (250×420) mm
Working Pressure 0.22MPa
Working Temperature 134℃
Chamber Volume 35L φ (300×500) mm
Working Pressure 0.22MPa
Working Temperature 134℃
Chamber Volume 16L φ (250×360) mm
Working Pressure 0.22MPa
Working Temperature 134℃
Chamber Volume 24L φ (250×520) mm
Working Pressure 0.22MPa
Working Temperature 134℃

Horizontal Autoclave

Horizontal Autoclave ADHA-504
Volume:280 L
Door Structure:spoke
Temperature Range:105 to 135°C
Horizontal Autoclave ADHA-503
Volume:500 L
Door Structure :spoke
Temperature Range :105 to 135°C
Horizontal Autoclave ADHA-507
Sterilizing chamber volume:150 L φ (440×1000mm)
working pressure:0.22Mpa
Working temperature:134ºC
Horizontal Autoclave ADHA-506
Volume:500 L
Door Structure :spoke
Temperature Range :105°C to 135°C
Horizontal Autoclave ADHA-502
Volume:360 L
Door Structure:spoke
Temperature Range :105 to 135°C
Horizontal Autoclave ADHA-508
Sterilizing Chamber Volume:200 L φ (515×1000mm)
Working Pressure:0.22Mpa
Working Temperature:134ºC
Horizontal Autoclave ADHA-501
Volume:280 L
Door Structure :spoke
Temperature Range :105 to 135°C
Horizontal Autoclave ADHA-505
Volume:360 L
Door Structure:spoke
Temperature Range:105 to 135°C

Portable Autoclave

Portable Autoclave ADPA-508
Chamber Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-505
Working Pressure:0.14 to 0.16MPa
Working Temperature:126 ºC
Temperature Adjust Range:105℃ to 126℃
Portable Autoclave ADPA-509
Chamber Volume:24L (280×390) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-506
Sterilizing Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16MPa
Working Temperature:126 ºC
Portable Autoclave ADPA-502
Sterilizing Volume:18L 80×260 mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature:126℃
Portable Autoclave ADPA-507
Chamber Volume:12L (240×200) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-504
Chamber Volume:24L (280 × 390) mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature :126℃
Portable Autoclave ADPA-503
Chamber Volume:18L (280 × 260) mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature:126℃
Portable Autoclave ADPA-501
Sterilizing Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16MPa
Working Temperature:126℃

Vertical Autoclave

Vertical Autoclave ADVA-535
Volume:65 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C

USD 7,620.00

Vertical Autoclave ADVA-501
Chamber Volume:35Lφ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-532
Volume:60 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C

USD 4,900.00

Vertical Autoclave ADVA-511
Chamber Volume:120L φ (480×660) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-521
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-531
Volume:100 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa

USD 3,900.00

Vertical Autoclave ADVA-506
Chamber Volume:150L φ (510×740) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-533
Volume:85 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C

USD 5,200.00

Vertical Autoclave ADVA-534
Volume:110 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C

USD 5,480.00

Vertical Autoclave ADVA-507
Chamber Volume:35L φ(318×450) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-512
Chamber Volume:100L φ (510×740) mm
Working Pressure 0.1 to 0.22MPa:0.1 to 0.22MPa
Working Temperature 120 to 134℃:120 to 134℃
Vertical Autoclave ADVA-514
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-503
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-525
Chamber Volume:50L φ (340×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-530
Volume:75 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa

USD 3,350.00

Vertical Autoclave ADVA-517
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-528
Volume:29 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa

USD 2,380.00

Vertical Autoclave ADVA-510
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-508
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-526
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-529
Volume:50 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa

USD 2,850.00

Vertical Autoclave ADVA-504
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22Mpa
Working Temperature:134℃
Vertical Autoclave ADVA-505
Chamber Volume:120L(φ480×660) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-522
Chamber Volume:50L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-536
Volume:90 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C

USD 8,220.00

Vertical Autoclave ADVA-520
Chamber Volume:100 L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-518
Chamber Volume:50 L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-519
Chamber Volume:75L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-513
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-502
Chamber Volume:50L(φ340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-515
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-527
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-516
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.14MPa
Working Temperature:126℃
Vertical Autoclave ADVA-524
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-523
Chamber Volume:75L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-509
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃