| Volume | 90 L |
| Sterilization Temperature | 105 to 135°C |
| Temperature Fluctuation | ±1°C |
| Temperature Uniformity | ±1°C |
| Heat Preservation Temperature | 40 to 60°C |
| Environment Temperature | 5 to 40°C |
| Environment Humidity | 20% to 80% RH |
| Melting Temperature | 60 to 100°C |
| Sterilization Timer Range | 0 to 240 min |
| Melting Timer Range | 0 to 6000 min |
| Heat Preservation Timer Range | 0 to 6000 min |
| Reservation Range | 0 to 99hr60 min |
| Design Pressure | 0.39 MPa |
| Working Pressure | 0.24 MPa |
| Pressure gauge indicating Range | 0-0.4 MPa |
| Drum Diameter | 400 mm |
| Number of Baskets | 3 pc |
| Power Consumption | 2.7 kW |
| Power Supply | 220±10 V, 50±2 Hz |
| Cavity Size [W×D] | Ø380×610 mm |
| Housing Dimensions [W×D×H] | 605×513×1040 mm |
| Basket Dimensions [W×D×H] | Ø380×735 mm |
| Package Dimensions [W×D×H] | 630×740×1300 mm |
| Net Weight | 89 kg |
| Gross Weight | 103 kg |
Our Vertical Autoclave ADVA-536 is widely used across industries such as healthcare for sterilizing surgical tools, pharmaceuticals for preparing sterile media, and research laboratories for ensuring aseptic experimental conditions.
1. What is the sterilization pressure in a Vertical Autoclave?
A Vertical Autoclave typically operates at 15 to 30 psi (pounds per square inch) during sterilization. The pressure helps raise the steam temperature above boiling point for efficient sterilization.
2. Is it necessary to dry items after sterilizing in a Vertical Autoclave?
Yes, drying is important after using a Vertical Autoclave to avoid moisture retention, which can promote microbial growth. Some models have built-in drying systems; others require manual drying.
3. What is a Vertical Autoclave and how does it work?
A Vertical Autoclave is a sterilization device that uses steam under pressure to sterilize equipment, media, and laboratory tools. It works by heating water to produce steam, which destroys bacteria, viruses, and other microorganisms.
4. What safety features are included in a Vertical Autoclave?
A Vertical Autoclave includes safety features like pressure release valves, temperature cut-offs, door interlocks, and alarms. These systems prevent accidental opening or overheating in the Vertical Autoclave. Built-in sensors ensure the unit shuts off in case of any malfunction.
5. Can a Vertical Autoclave be used for medical waste?
A Vertical Autoclave can be used to sterilize soft medical waste like gauze, gloves, and cloth items. However, a Vertical Autoclave may not be ideal for large volumes of waste or sharp objects. Special medical waste autoclaves are recommended for such loads.
| Volume | 85 L |
| Sterilization Temperature | 105 to 135°C |
| Temperature Fluctuation | ±1°C |
| Chamber Volume | 50L φ (318×450) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Volume | 60 L |
| Sterilization Temperature | 105 to 135°C |
| Temperature Fluctuation | ±1°C |
| Chamber Volume | 35L φ (318×450) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Volume: | 280 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105°C to 135°C |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range : | 105 to 135°C |
| Sterilizing Chamber Volume: | 200 L φ (515×1000mm) |
| Working Pressure: | 0.22Mpa |
| Working Temperature: | 134ºC |
| Volume: | 280 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Sterilizing chamber volume: | 150 L φ (440×1000mm) |
| working pressure: | 0.22Mpa |
| Working temperature: | 134ºC |
| Chamber Volume: | 24L (280 × 390) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature : | 126℃ |
| Chamber Volume: | 18L (280 × 260) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Temperature Adjust Range: | 105℃ to 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L 80×260 mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 24L (280×390) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 12L (240×200) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Chamber Volume: | 16L φ (250×360) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 50L φ (340×550) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 35L φ (300×500) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 24L φ (250×520) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 20L φ (250×420) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 24L φ (270×410) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |