Portable Autoclave ADPA-506

Portable Autoclave ADPA-506

Advalab Portable Autoclave ADPA-506 provides an 18 liter chamber with a working temperature of 126 degrees Celsius for steam sterilization. The portable autoclave machine works as a digital autoclave, with touch keys, a display for temperature, pressure, time, plus alarms for low water or errors. As an electric autoclave sterilizer, this stainless steel autoclave shuts off automatically with a beep when the cycle ends. This portable autoclave sterilizer also works as a portable steam sterilizer that moves between rooms. Our portable autoclave laboratory range supports hospitals, clinics,and research facilities handling medical equipment, surgical dressings, glass utensils, and liquids.


Sterilizing volume 18L, φ280×260 mm
Working pressure 0.14–0.16 MPa
Working temperature 126 °C
Temperature adjust range 105–126 °C
Timer range 0–99 min
Max. safety pressure 0.165 MPa
Heat average ≤ ±1 °C
Power 2 kW, AC220V 50Hz
Dimensions 420×420×630 mm (transport)
Automatic pressure release Yes
Whether the pressure gauge and safety valve come as standard yes
Heat-up time 0 min ~99min
Suitability for waste sterilization Yes
Water Consumption per Cycle 6–7 L for initial use; 800 mL–1 L for each subsequent cycle
Temperature and pressure control Digital display, touch keys, adjustable temperature, panel shows temperature, pressure, time
Compact and lightweight Portable design
User-friendly Easy to operate, safe and reliable”, plus low-water and error alarms
Net Weight 12 kg
Gross Weight 14 kg

Primary Functions:
– Sterilizing medical equipment
– Sterilizing surgical dressings
– Sterilizing glass utensils
Application Domain:
– Hospitals
– Public health centers
– Clinics

Frequently Asked Questions of Portable Autoclave ADPA-506

1. What is a portable autoclave and how does it work?

A portable autoclave is a compact, self-contained sterilization device designed to decontaminate medical instruments, laboratory tools, or any reusable equipment that may harbor microorganisms. It operates primarily using high-pressure steam, which is one of the most effective and widely accepted methods for sterilization. The process typically involves heating water to produce steam under pressure, reaching temperatures around 121°C (250°F) or higher.

2. What are the main applications of a portable autoclave?

Portable autoclaves are incredibly versatile and are used in a wide range of applications where on-site sterilization is critical. Common use cases include rural health clinics, mobile medical units, veterinary practices, dental offices, field laboratories, and even tattoo or piercing studios. They are ideal for sterilizing surgical instruments, and glasswares.

3. What materials or instruments can be sterilized in a portable autoclave?

Most portable autoclaves are designed to sterilize a wide variety of instruments and materials, provided they are heat-resistant and steam-compatible. This includes stainless steel surgical tools, glass petri dishes, forceps, scissors, metal trays, cotton swabs, gauze, and some plastics marked as “autoclavable.” It’s important to avoid placing items made of low-melting-point plastics, electronics, or any sealed containers that could explode under pressure. Always check the manufacturer’s guidance to ensure that items are compatible with steam sterilization. Proper loading is also essential—items should be arranged to allow steam to circulate freely for effective sterilization.

4. How long does it take to complete a sterilization cycle in a portable autoclave?

The duration of a sterilization cycle in a portable autoclave can vary depending on the model, the volume of items being sterilized, and the specific settings used. Generally, a typical cycle runs anywhere from 15 to 30 minutes at 121°C (250°F) under 15–20 psi of pressure. However, it’s important to account for the time it takes to build up the required pressure and temperature, as well as the cooldown period before the chamber can be safely opened. Altogether, a full cycle may take 45 to 60 minutes from start to finish. It's critical not to interrupt the cycle prematurely, as doing so can result in incomplete sterilization and put patients, staff, or lab results at risk.

5. What are the ideal temperature and pressure settings for effective sterilization?

For most portable autoclaves, the ideal sterilization conditions are a temperature of 121°C (250°F) with a pressure of about 15 psi, maintained for at least 15 to 20 minutes. These parameters are recognized as the gold standard for steam sterilization and are sufficient to eliminate bacteria, viruses, fungi, and even highly resistant bacterial spores. Some models allow for higher temperature settings, such as 134°C (273°F), which reduce the required exposure time but demand more robust instruments. It's essential to follow the autoclave manufacturer's guidelines and ensure instruments are compatible with the selected sterilization parameters to avoid damaging sensitive materials.

Similar Products of Portable Autoclave

Sterilizing Volume 18L 80×260 mm
Working Pressure 0.14 to 0.16 MPa
Working Temperature 126℃
Sterilizing Volume 18L (280×260) mm
Working Pressure 0.14 to 0.16MPa
Working Temperature 126℃
Chamber Volume 24L (280×390) mm
Working Pressure 0.14 to 0.16Mpa
Working Temperature 126℃
Chamber Volume 18 L (240×200) mm
Working Pressure 0.14 to 0.16Mpa
Working Temperature 126℃

Horizontal Autoclave

Horizontal Autoclave ADHA-507
Sterilizing chamber volume:150 L φ (440×1000mm)
working pressure:0.22Mpa
Working temperature:134ºC
Horizontal Autoclave ADHA-504
Volume:280 L
Door Structure:spoke
Temperature Range:105 to 135°C
Horizontal Autoclave ADHA-502
Volume:360 L
Door Structure:spoke
Temperature Range :105 to 135°C
Horizontal Autoclave ADHA-505
Volume:360 L
Door Structure:spoke
Temperature Range:105 to 135°C
Horizontal Autoclave ADHA-508
Sterilizing Chamber Volume:200 L φ (515×1000mm)
Working Pressure:0.22Mpa
Working Temperature:134ºC
Horizontal Autoclave ADHA-501
Volume:280 L
Door Structure :spoke
Temperature Range :105 to 135°C
Horizontal Autoclave ADHA-506
Volume:500 L
Door Structure :spoke
Temperature Range :105°C to 135°C
Horizontal Autoclave ADHA-503
Chamber volume:~398 L (calculated from Ø620×1320 mm
Chamber dimensions:Ø620 × 1320 mm
Overall dimensions:1755 × 850 × 1760 mm

Vertical Autoclave

Vertical Autoclave ADVA-519
Chamber Volume:75L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-533
Volume:85 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-505
Chamber Volume:120L(φ480×660) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-506
Chamber Volume:150L φ (510×740) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-525
Chamber Volume:50L φ (340×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-528
Volume:29 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa
Vertical Autoclave ADVA-515
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-522
Chamber Volume:50L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-514
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-504
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22Mpa
Working Temperature:134℃
Vertical Autoclave ADVA-517
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-520
Chamber Volume:100 L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-524
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-523
Chamber Volume:75L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-535
Volume:65 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-531
Volume:100 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa
Vertical Autoclave ADVA-513
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-527
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-526
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-507
Chamber Volume:35L φ(318×450) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-511
Chamber Volume:120L φ (480×660) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-521
Chamber Volume:35L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-502
Chamber Volume:50L(φ340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-518
Chamber Volume:50 L φ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-536
Volume:90 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-509
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-501
Chamber Volume:35Lφ (318×450) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-529
Volume:50 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa
Vertical Autoclave ADVA-508
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-532
Volume:60 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-510
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.1 to 0.22MPa
Working Temperature:120 to 134℃
Vertical Autoclave ADVA-537
Capacity:60 L
Chamber Size:Φ 350 x 550 mm
Basket Size:330 x 190 (× 2)
Vertical Autoclave ADVA-503
Chamber Volume:75L φ (400×600) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Vertical Autoclave ADVA-534
Volume:110 L
Sterilization Temperature:105 to 135°C
Temperature Fluctuation:±1°C
Vertical Autoclave ADVA-530
Volume:75 L
Maximum Working Temperature:135°C to 139°C
Maximum Working Pressure:0.22 to 0.25 MPa
Vertical Autoclave ADVA-512
Chamber Volume:100L φ (510×740) mm
Working Pressure 0.1 to 0.22MPa:0.1 to 0.22MPa
Working Temperature 120 to 134℃:120 to 134℃
Vertical Autoclave ADVA-516
Chamber Volume:100L φ (440×650) mm
Working Pressure:0.14MPa
Working Temperature:126℃

Benchtop Autoclave

Benchtop Autoclave ADBA-503
Chamber Volume:20L φ (250×420) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-505
Chamber Volume:35L φ (300×500) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-504
Chamber Volume:24L φ (250×520) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-506
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-501
Chamber Volume:16L φ (250×360) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-502
Chamber Volume:24L φ (270×410) mm
Working Pressure:0.22MPa
Working Temperature:134℃