| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 9.5 L |
| Freeze Drying Area | 0.09 m² |
| Water Capture Capacity | 4 Kg/batch |
| Vacuum Degree | <10 Pa |
| Vacuum Pump | 2 L/s |
| Refrigerant | R404a +R290+R23 |
| Shelf Quantity | 3 pcs |
| Shelf Space | 70 mm |
| Loading Capacity | 300 ml |
| Total Loading Capacity | 900 ml |
| Tray Size | ф200 × 20 mm |
| Tray Quantity | 3 pcs |
| Vial Capacity |
Ø22:195 vials Ø16:360 vials Ø12:690 |
| Cold Trap Size | Ф217 × 250 mm |
| Drying Chamber Dimension | Ф240(260) × 450 mm |
| Noise Level | <66 dB |
| Power Consumption | 0.95 (to1.5) kW |
| Main Unit packing size (W x D x H) | 730 × 600 × 1180 mm |
| Dimension (W x D x H) | 410 × 410 × 640 mm |
| Vacuum Pump packaging size (W x D x H) | 220 × 580 × 370 mm |
| Overall Dimensions (W x D x H) | 480 × 610 × 905 (to 1415) mm |
| Net Weight | 85 (to 100) Kg |
| Gross Weight | 150 (to170) Kg |
The Floor Type Freeze Dryer ADFFD-506, equipped with a large opening and coil-free chamber, is designed for sample pre-freezing in pharmaceutical and biotech labs, enhancing moisture removal.
Vacuum Pump | 1unit |
Trays | 3 unit |
Drying Rack | 1unit |
Acrylic Cover | 1unit |
Acrylic Bucket | 1unit |
Vacuum Pump Outlet Oil Mist Filter | 1unit |
Vacuum Pump Inlet Dust Filter | 1unit |
Vacuum Pump Inlet Vapor Filter | 1unit |
| Electric Defrosting | 1unit |
| Shelf Heating | 1unit |
1. What maintenance support features does the Floor Type Freeze Dryer include?
For user convenience and system longevity, the dryer incorporates a vacuum pump timer to schedule regular maintenance. A built-in self-diagnosis function detects faults in core components and notifies the user, helping prevent unexpected downtime. Accessible drain and inflation valves allow for straightforward maintenance, enhancing of use during daily operation.
2. Why is Floor Type Freeze Dryer a reliable choice for laboratory and industrial settings?
Its programmable PLC system gives users complete control over the freeze-drying cycle, including pressure, temperature, and duration settings for reproducibility. It features vacuum pump start protection and large-capacity data storage for drying curves and alerts contribute to consistent, validated results. This makes it ideal for use in regulated environments with a focus on quality and repeatability.
3. How does the Floor Type Freeze Dryer safe handling of temperature sensitive materials?
This Freeze Dryer is engineered to maintain the stability of delicate samples such as enzymes, vaccines, and probiotics. Programmable temperature settings and vacuum control allow for adjustments to each sample’s needs. The nitrogen-compatible inflation valve minimizes oxidation, preserving sample integrity. Its controlled environment ensures sublimation, making it highly suitable for research and production involving thermally sensitive compounds.
4. What industries benefit most from the Floor Type Freeze Dryer?
The Floor Type Freeze Dryer is ideal for pharmaceutical manufacturing, biotech research, food processing labs, and academic institutions. It effectively dries heat- and oxygen-sensitive products, such as plant extracts, culture media, and biologics. With reliable automation and a user-friendly interface, it supports both small-batch research and medium-scale production settings.
5. How does Floor Type Freeze Dryer enhance drying efficiency in high-demand labs?
Equipped with a cold trap that reaches below -60°C, the system efficiently condenses vapor to shorten cycle time. Its ability to maintain vacuum below setpoints speeds up sublimation, while the fully automated PLC-based control reduces manual handling errors. These features ensure rapid, consistent drying and are well-suited for facilities requiring high throughput and time-sensitive processing.
6. What are the key features of a Floor Type Freeze Dryer?
Floor Type Freeze Dryers are equipped with several key features for efficient, high-quality drying. These include large chamber capacities, which allow for processing larger sample volumes, and programmable controls. Real-time monitoring tracks key parameters like temperature and vacuum pressure, ensuring optimal drying conditions. Low-noise operation makes them suitable for continuous use in laboratory settings.
7. How does a Floor Type Freeze Dryer work?
The Floor Type Freeze Dryer works through a three-stage process. First, the sample is frozen to ultra-low temperatures, turning the water content into ice. Next, during the primary drying phase, a vacuum is applied to sublimate the ice directly into vapor, bypassing the liquid phase. In the secondary drying phase, residual moisture is removed by gradually increasing the temperature. This ensures that the sample reaches its final dry state while preserving its integrity.
8. What is a Floor Type Freeze Dryer used for?
A Floor Type Freeze Dryer is used for efficiently Freeze-Drying large volumes of sensitive materials in industries like pharmaceuticals, biotechnology, food processing, and chemicals. They preserve vaccines, enzymes, plant extracts, and other moisture-sensitive materials by removing moisture through sublimation. This process maintains the integrity, potency, and stability of the sample without altering its structure or bioactivity, making it ideal for long-term storage.
| Temperature Range | ≤–80℃ |
| Vacuum Level | < 10 Pa |
| Total Drying Area | 0.12m² |
| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 28 L |
| Temperature Range | ≤–80℃ |
| Vacuum Level | < 10 Pa |
| Total Drying Area | 0.07m² |
| Temperature Range | ≤–80℃ |
| Vacuum Level | < 10 Pa |
| Total Drying Area | 0.07m² |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.12 m² |
| Type: | Stoppering chamber |
| Freeze Dry Area: | 0.09 m² |
| Water Capture Capacity: | 4kg/24h |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.11m² |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.12 m² |
| Type: | Standard chamber with 8 port manifolds |
| Freeze Dry Area: | 0.12m² |
| Water Capture Capacity: | 4kg/24h |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Temperature Range: | ≤-50℃ |
| Vacuum Level <10 Pa: | <10 Pa |
| Freeze-Dry Area : | 0.07 m² |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.07 m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.11m² |
| Type: | Standard chamber |
| Freeze Dry Area: | 0.12m² |
| Water Capture Capacity: | 4kg/24h |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |