Portable Dissolved Oxygen Meter ADPOM-501 measures dissolved oxygen over a broad range of 0 to 20 mg/L. With high resolution and accuracy, this unit offers reliable readings for sensitive samples. It precisely detects fine oxygen saturation changes in all sample concentrations with 0.1% resolution. A response time of ≤45 sec enables rapid analysis and real-time sample monitoring. This Oxygen Meter is suitable for monitoring dissolved oxygen levels in industrial, agricultural and wastewater applications.
Dissolved Oxygen Concentration Measuring Range | 0 to 20 mg/L |
Dissolved Oxygen Concentration Resolution | 0.01 mg/L |
Dissolved Oxygen Concentration Accuracy | ≤±0.30 mg/L |
Dissolved Oxygen Saturation Measuring Range | 0 to 200% |
Dissolved Oxygen Saturation Resolution | 0.001 |
Dissolved Oxygen Saturation Accuracy | ≤±3.0% |
Temperature Measuring Range | 0 to 60⁰C |
Temperature Resolution | 0.1⁰C |
Temperature Accuracy | ≤±0.3⁰C |
Response Time | ≤45 sec |
Atmospheric Pressure Compensation | 60 to 110 Kpa (manual) |
Salinity Compensation | 0 to 50 g/L (manual) |
Temperature Compensation | 0 to 40⁰C (automatic) |
Standard Electrode | SD02 type dissolved oxygen electrode, 3 meters cable |
Environmental Protection Level | IP65 |
Power Supply | Lithium battery |
Dimensions (L×W×H) | 165×75×51 mm |
Weight | 270 g (without sensor) |
Our Portable Dissolved Oxygen Meter is widely utilized in aquaculture, environmental monitoring, water treatment plants, research laboratories and food industries for accurate measurement of dissolved oxygen concentrations in water samples.
Dissolved Oxygen Measuring Range | 0 to 20 mg/L |
Saturation Measuring Range | 0 to 200% |
Temperature Measuring Range | 0 to 50℃ |
$1,120.00
Dissolved Oxygen Measuring Range | 0 to 20mg/L;0 to 200% |
Resolution Ratio | 0.01mg/L;0.1% |
Measurement Accuracy | 0.05mg/L;0.5% |
$240.00
COD Range: | 0 to 10000 mg/L (Customized) |
Principle: | UV 254 |
Resolution: | 0.01 mg/L |
$4,460.00
COD Test Method: | Potassium dichromate method<br/> Alkaline potassium permanganate |
COD Measuring Range: | 10 to 15000mg/L<br/> 0.5 to 25mg/L |
COD Test Limit: | 10mg/L<br/> 0.5mg/L |
$1,610.00
Indication Error: | ≤±5% |
Repeatability: | 0.03 |
COD Detection Method: | Potassium dichromate method, Potassium permanganate method |
$2,310.00
Absorbance Detection Range: | 0 to 3Abs |
Optical Path Stability: | ≤±0.005Abs/30min |
Absorbance Resolution: | 0.001Abs |
$1,380.00
COD Detection Method: | Potassium dichromate method<br/> Potassium permanganate method |
COD Measuring Range: | 10 to 15000 mg/L |
COD Lower Limit of Measurement: | 3 mg/L |
$3,590.00
Test Parameter: | Residual Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
$310.00
Test Parameter: | Ozone |
Measuring Range: | 0.05 to 2.5mg/L |
Wavelength: | 520 nm |
$310.00
Test Parameter: | Chlorine dioxide |
Measuring Range: | 0.1 to 5 mg/L |
Wavelength: | 520 nm |
$310.00
Test Parameter: | Ammonia nitrogen |
Measuring Range: | 0.01 to 10mg/L |
Wavelength: | 420 nm |
$310.00
Test Parameter: | Total Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
$310.00
Measuring Range: | 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU) |
Accuracy: | ±0.1NTU or ±5%<br/> ±0.3NTU or ±8% |
Repeatability: | ≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU |
$900.00
TSS Measuring Range: | 0 to 1000mg/L |
TSS Accuracy: | ±0.3mg/L or ±8% |
TSS Repeatability: | <10mg/L: ≤±0.1mg/L <br/> ≥10mg/L: ≤±1% |
$1,320.00
TDS Range: | 0 to 9999 ppm |
Conductivity Range: | 0 to 9999 μS/cm |
Temperature Range: | 0 to 80℃ or 32 to 176℃ |
$50.00
Measuring Range: | 0 to 10% |
Measuring Temperature Range: | 0 to 99℃ |
Resolution: | 0.01%,0.1℃ |
$120.00
Temperature Control Range: | Room temperature to 180℃ |
Digestion Temperature Range: | 50 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
$1,400.00
Temperature Control Range: | 45 to 180℃ |
Digestion Temperature: | 45 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
$1,850.00
pH Measuring Range: | -2 to 16 pH |
pH resolution: | 0.1pH |
pH indication error: | ±0.2% F.S. |
$420.00
ORP Measuring Range: | -1000mV to 1000mV |
ORP Resolution: | 1 mV |
ORP measurement Accuracy: | ±0.5% F.S. |
$160.00
pH Measuring Range: | 0 to 14 pH |
pH Resolution: | 0.041 pH |
pH Indication Error: | ±0.02 pH |
$400.00
pH Measuring Range: | 0 to 14pH |
pH Resolution: | 0.01pH |
pH Measuring Accuracy: | ±0.01pH |
$450.00