COD Analyzer ADCOD-501 is designed with a measurement range of 0 to 10,000 mg/L ensuring reliable readings. It operates on the UV 254 nm ensuring reliable identification of organic compounds in water. It features a built-in temperature sensor, enabling temperature measurement and compensation during analysis. Our analyzer includes an LCD for convenient operation and monitoring of parameters.
COD Range | 0 to 10000 mg/L (Customized) |
Principle | UV 254 |
Resolution | 0.01 mg/L |
Housing Material | SS316 / Titanium (Customized) |
Output Signal | RS485 / Modbus |
Accuracy | 3% to 5% FS |
Calibration | 3-point calibration |
Power Supply | 12VDC ±5% |
Dimension of COD Sensor’s Analyzer | 144×144×115 mm (Controller size) |
Dimensions of COD Sensor | 234×78×46 mm |
Weight | 0.65 Kg |
COD Analyzer ADCOD-501 is used to measure the amount of organic pollutants in water. It is widely used in fields such as Water Quality Monitoring, Wastewater Treatment, Environmental Protection, and Process Control.
Indication Error: | ≤±5% |
Repeatability: | 0.03 |
COD Detection Method: | Potassium dichromate method, Potassium permanganate method |
COD Test Method: | Potassium dichromate method<br/> Alkaline potassium permanganate |
COD Measuring Range: | 10 to 15000mg/L<br/> 0.5 to 25mg/L |
COD Test Limit: | 10mg/L<br/> 0.5mg/L |
Absorbance Detection Range: | 0 to 3Abs |
Optical Path Stability: | ≤±0.005Abs/30min |
Absorbance Resolution: | 0.001Abs |
COD Detection Method: | Potassium dichromate method<br/> Potassium permanganate method |
COD Measuring Range: | 10 to 15000 mg/L |
COD Lower Limit of Measurement: | 3 mg/L |
Dissolved Oxygen Measuring Range: | 0 to 20 mg/L |
Saturation Measuring Range: | 0 to 200% |
Temperature Measuring Range: | 0 to 50℃ |
Dissolved Oxygen Measuring Range: | 0 to 20mg/L;0 to 200% |
Resolution Ratio: | 0.01mg/L;0.1% |
Measurement Accuracy: | 0.05mg/L;0.5% |
Dissolved Oxygen Concentration Measuring Range: | 0 to 20 mg/L |
Dissolved Oxygen Concentration Resolution: | 0.01 mg/L |
Dissolved Oxygen Concentration Accuracy: | ≤±0.30 mg/L |
Test Parameter: | Ammonia nitrogen |
Measuring Range: | 0.01 to 10mg/L |
Wavelength: | 420 nm |
Test Parameter: | Residual Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Chlorine dioxide |
Measuring Range: | 0.1 to 5 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Total Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Ozone |
Measuring Range: | 0.05 to 2.5mg/L |
Wavelength: | 520 nm |
Measuring Range: | 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU) |
Accuracy: | ±0.1NTU or ±5%<br/> ±0.3NTU or ±8% |
Repeatability: | ≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU |
TSS Measuring Range: | 0 to 1000mg/L |
TSS Accuracy: | ±0.3mg/L or ±8% |
TSS Repeatability: | <10mg/L: ≤±0.1mg/L <br/> ≥10mg/L: ≤±1% |
TDS Range: | 0 to 9999 ppm |
Conductivity Range: | 0 to 9999 μS/cm |
Temperature Range: | 0 to 80℃ or 32 to 176℃ |
Measuring Range: | 0 to 10% |
Measuring Temperature Range: | 0 to 99℃ |
Resolution: | 0.01%,0.1℃ |
Temperature Control Range: | Room temperature to 180℃ |
Digestion Temperature Range: | 50 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
Temperature Control Range: | 45 to 180℃ |
Digestion Temperature: | 45 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
pH Measuring Range: | -2 to 16 pH |
pH resolution: | 0.1pH |
pH indication error: | ±0.2% F.S. |
ORP Measuring Range: | -1000mV to 1000mV |
ORP Resolution: | 1 mV |
ORP measurement Accuracy: | ±0.5% F.S. |
pH Measuring Range: | 0 to 14pH |
pH Resolution: | 0.01pH |
pH Measuring Accuracy: | ±0.01pH |
pH Measuring Range: | 0 to 14 pH |
pH Resolution: | 0.041 pH |
pH Indication Error: | ±0.02 pH |