| Test Parameter | Total Chlorine |
| Measuring Range | 0.05 to 10 mg/L |
| Wavelength | 520 nm |
| Principle | N, N-diethyl-1,4-phenylenediamine spectrophotometric method |
| Accuracy | <1.0 mg/L, ≤±0.05mg/L, ≥1.0 mg/L, ≤±5% |
| Light Source | LED light emitting diode |
| Battery Life | More than 24 hours (without shutdown) |
| Dimension (L×W×H) | 128×70×48 mm |
| Weight | 188 g |
Portable Water Quality Analyzer ADPWA-502 delivers an optimal performance in water treatment plants, industrial wastewater management, agriculture, aquaculture and research laboratories. It analyses water samples to help monitor water quality and maintain ideal conditions.
| Test Parameter | Ozone |
| Measuring Range | 0.05 to 2.5mg/L |
| Wavelength | 520 nm |
| Test Parameter | Chlorine dioxide |
| Measuring Range | 0.1 to 5 mg/L |
| Wavelength | 520 nm |
| Test Parameter | Residual Chlorine |
| Measuring Range | 0.05 to 10 mg/L |
| Wavelength | 520 nm |
| Test Parameter | Ammonia nitrogen |
| Measuring Range | 0.01 to 10mg/L |
| Wavelength | 420 nm |
| COD Range: | 0 to 10000 mg/L (Customized) |
| Principle: | UV 254 |
| Resolution: | 0.01 mg/L |
| Absorbance Detection Range: | 0 to 3Abs |
| Optical Path Stability: | ≤±0.005Abs/30min |
| Absorbance Resolution: | 0.001Abs |
| COD Detection Method: | Potassium dichromate method<br/> Potassium permanganate method |
| COD Measuring Range: | 10 to 15000 mg/L |
| COD Lower Limit of Measurement: | 3 mg/L |
| COD Test Method: | Potassium dichromate method<br/>Alkaline potassium permanganate |
| COD Measuring Range: | 10 to 15000mg/L<br/>0.5 to 25mg/L |
| COD Test Limit: | 10mg/L<br/>0.5mg/L |
| Indication Error: | ≤±5% |
| Repeatability: | 0.03 |
| COD Detection Method: | Potassium dichromate method, Potassium permanganate method |
| Dissolved Oxygen Concentration Measuring Range: | 0 to 20 mg/L |
| Dissolved Oxygen Concentration Resolution: | 0.01 mg/L |
| Dissolved Oxygen Concentration Accuracy: | ≤±0.30 mg/L |
| Dissolved Oxygen Measuring Range: | 0 to 20 mg/L |
| Saturation Measuring Range: | 0 to 200% |
| Temperature Measuring Range: | 0 to 50℃ |
| Dissolved Oxygen Measuring Range: | 0 to 20mg/L;0 to 200% |
| Resolution Ratio: | 0.01mg/L;0.1% |
| Measurement Accuracy: | 0.05mg/L;0.5% |
| Measuring Range: | 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU) |
| Accuracy: | ±0.1NTU or ±5%<br/> ±0.3NTU or ±8% |
| Repeatability: | ≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU |
| TSS Measuring Range: | 0 to 1000mg/L |
| TSS Accuracy: | ±0.3mg/L or ±8% |
| TSS Repeatability: | <10mg/L: ≤±0.1mg/L <br/>≥10mg/L: ≤±1% |
| TSS Measuring Range: | 0.1 to 50000 mg/L |
| TSS Accuracy: | ± 5% FS (depending on the homogeneity of the activated sludge) |
| TSS Repeatability: | <1% |
| TDS Range: | 0 to 9999 ppm |
| Conductivity Range: | 0 to 9999 μS/cm |
| Temperature Range: | 0 to 80℃ or 32 to 176℃ |
| Measuring Range: | 0 to 10% |
| Measuring Temperature Range: | 0 to 99℃ |
| Resolution: | 0.01%,0.1℃ |
| Temperature Control Range: | Room temperature to 180℃ |
| Digestion Temperature Range: | 50 to 180℃ |
| Temperature Control Accuracy: | ±0.1℃ |
| Temperature Control Range: | 45 to 180℃ |
| Digestion Temperature: | 45 to 180℃ |
| Temperature Control Accuracy: | ±0.1℃ |
| pH Measuring Range: | -2 to 16 pH |
| pH resolution: | 0.1pH |
| pH indication error: | ±0.2% F.S. |
| ORP Measuring Range: | -1000mV to 1000mV |
| ORP Resolution: | 1 mV |
| ORP measurement Accuracy: | ±0.5% F.S. |
| pH Measuring Range: | 0 to 14 pH |
| pH Resolution: | 0.041 pH |
| pH Indication Error: | ±0.02 pH |
| pH Measuring Range: | 0 to 14pH |
| pH Resolution: | 0.01pH |
| pH Measuring Accuracy: | ±0.01pH |