pH/ORP Meter ADPO-501 measures both pH and ORP values over a wide range of 0 to 14pH and -1999 to 1999mV respectively. It offers high resolution with precise readings, minimizing deviations. With a wide temperature range of 0 to 80℃, this unit enables testing of various sample types. Featuring a compact and lightweight design, it is simple to operate, enhancing user convenience. Ideal for use in wastewater treatment plants, environmental monitoring and beverage industries, it helps in quality analysis in various processes.
pH Measuring Range | 0 to 14pH |
pH Resolution | 0.01pH |
pH Measuring Accuracy | ±0.01pH |
ORP Measuring Range | -1999 to 1999mV |
ORP Resolution | 1mV |
ORP Measuring Accuracy | ±0.1% Full Scale |
Temperature Measuring Range | 0 to 80.0℃; 32 to 176℉ |
Temperature Resolution | 0.1℃;0.1℉ |
Temperature Measuring Accuracy | ±0.5℃ |
Power Supply | AAA battery× 3 |
Dimensions (L×B×H) | 165×75×51 mm |
Weight | 270g (No Battery) |
Our pH/ORP Meter is widely utilized in wastewater treatment plants, environmental monitoring, chemical, pharmaceutical, agricultural and environmental monitoring, delivering accurate pH and ORP values to help in water quality assessment.
pH Measuring Range | 0 to 14 pH |
pH Resolution | 0.041 pH |
pH Indication Error | ±0.02 pH |
COD Range: | 0 to 10000 mg/L (Customized) |
Principle: | UV 254 |
Resolution: | 0.01 mg/L |
COD Test Method: | Potassium dichromate method<br/> Alkaline potassium permanganate |
COD Measuring Range: | 10 to 15000mg/L<br/> 0.5 to 25mg/L |
COD Test Limit: | 10mg/L<br/> 0.5mg/L |
COD Detection Method: | Potassium dichromate method<br/> Potassium permanganate method |
COD Measuring Range: | 10 to 15000 mg/L |
COD Lower Limit of Measurement: | 3 mg/L |
Indication Error: | ≤±5% |
Repeatability: | 0.03 |
COD Detection Method: | Potassium dichromate method, Potassium permanganate method |
Absorbance Detection Range: | 0 to 3Abs |
Optical Path Stability: | ≤±0.005Abs/30min |
Absorbance Resolution: | 0.001Abs |
Dissolved Oxygen Measuring Range: | 0 to 20 mg/L |
Saturation Measuring Range: | 0 to 200% |
Temperature Measuring Range: | 0 to 50℃ |
Dissolved Oxygen Measuring Range: | 0 to 20mg/L;0 to 200% |
Resolution Ratio: | 0.01mg/L;0.1% |
Measurement Accuracy: | 0.05mg/L;0.5% |
Dissolved Oxygen Concentration Measuring Range: | 0 to 20 mg/L |
Dissolved Oxygen Concentration Resolution: | 0.01 mg/L |
Dissolved Oxygen Concentration Accuracy: | ≤±0.30 mg/L |
Test Parameter: | Chlorine dioxide |
Measuring Range: | 0.1 to 5 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Ozone |
Measuring Range: | 0.05 to 2.5mg/L |
Wavelength: | 520 nm |
Test Parameter: | Total Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Ammonia nitrogen |
Measuring Range: | 0.01 to 10mg/L |
Wavelength: | 420 nm |
Test Parameter: | Residual Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
Measuring Range: | 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU) |
Accuracy: | ±0.1NTU or ±5%<br/> ±0.3NTU or ±8% |
Repeatability: | ≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU |
TSS Measuring Range: | 0 to 1000mg/L |
TSS Accuracy: | ±0.3mg/L or ±8% |
TSS Repeatability: | <10mg/L: ≤±0.1mg/L <br/> ≥10mg/L: ≤±1% |
TDS Range: | 0 to 9999 ppm |
Conductivity Range: | 0 to 9999 μS/cm |
Temperature Range: | 0 to 80℃ or 32 to 176℃ |
Measuring Range: | 0 to 10% |
Measuring Temperature Range: | 0 to 99℃ |
Resolution: | 0.01%,0.1℃ |
Temperature Control Range: | 45 to 180℃ |
Digestion Temperature: | 45 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
Temperature Control Range: | Room temperature to 180℃ |
Digestion Temperature Range: | 50 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
pH Measuring Range: | -2 to 16 pH |
pH resolution: | 0.1pH |
pH indication error: | ±0.2% F.S. |
ORP Measuring Range: | -1000mV to 1000mV |
ORP Resolution: | 1 mV |
ORP measurement Accuracy: | ±0.5% F.S. |