Thermoreactor ADTR-501 operates within a digestion temperature range of 50 to 180℃ for optimal sample processing. It can simultaneously process four samples, enhancing efficiency. Crafted using high quality, corrosion resistant materials, this unit is durable for long term operation. Equipped with a smart digital display, it allows real time monitoring of the process. Our Thermoreactor is versatile, making it ideal for applications in environmental, chemical and pharmaceutical laboratories.
Temperature Control Range | Room temperature to 180℃ |
Digestion Temperature Range | 50 to 180℃ |
Temperature Control Accuracy | ±0.1℃ |
Temperature Tolerance | ±1℃ |
Sample Processing Quantity | 4 samples |
Power Supply | DC 12V/10A |
Dimensions (L×B×H) | 110×170×125 mm |
Weight | 918g |
Our Thermoreactor has wide applications in biochemical laboratories, clinical diagnostics, and environmental analysis for digesting and analyzing water samples.
Temperature Control Range | 45 to 180℃ |
Digestion Temperature | 45 to 180℃ |
Temperature Control Accuracy | ±0.1℃ |
COD Range: | 0 to 10000 mg/L (Customized) |
Principle: | UV 254 |
Resolution: | 0.01 mg/L |
Absorbance Detection Range: | 0 to 3Abs |
Optical Path Stability: | ≤±0.005Abs/30min |
Absorbance Resolution: | 0.001Abs |
COD Test Method: | Potassium dichromate method<br/> Alkaline potassium permanganate |
COD Measuring Range: | 10 to 15000mg/L<br/> 0.5 to 25mg/L |
COD Test Limit: | 10mg/L<br/> 0.5mg/L |
Indication Error: | ≤±5% |
Repeatability: | 0.03 |
COD Detection Method: | Potassium dichromate method, Potassium permanganate method |
COD Detection Method: | Potassium dichromate method<br/> Potassium permanganate method |
COD Measuring Range: | 10 to 15000 mg/L |
COD Lower Limit of Measurement: | 3 mg/L |
Dissolved Oxygen Measuring Range: | 0 to 20 mg/L |
Saturation Measuring Range: | 0 to 200% |
Temperature Measuring Range: | 0 to 50℃ |
Dissolved Oxygen Measuring Range: | 0 to 20mg/L;0 to 200% |
Resolution Ratio: | 0.01mg/L;0.1% |
Measurement Accuracy: | 0.05mg/L;0.5% |
Dissolved Oxygen Concentration Measuring Range: | 0 to 20 mg/L |
Dissolved Oxygen Concentration Resolution: | 0.01 mg/L |
Dissolved Oxygen Concentration Accuracy: | ≤±0.30 mg/L |
Test Parameter: | Residual Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Total Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Chlorine dioxide |
Measuring Range: | 0.1 to 5 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Ammonia nitrogen |
Measuring Range: | 0.01 to 10mg/L |
Wavelength: | 420 nm |
Test Parameter: | Ozone |
Measuring Range: | 0.05 to 2.5mg/L |
Wavelength: | 520 nm |
Measuring Range: | 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU) |
Accuracy: | ±0.1NTU or ±5%<br/> ±0.3NTU or ±8% |
Repeatability: | ≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU |
TSS Measuring Range: | 0 to 1000mg/L |
TSS Accuracy: | ±0.3mg/L or ±8% |
TSS Repeatability: | <10mg/L: ≤±0.1mg/L <br/> ≥10mg/L: ≤±1% |
TDS Range: | 0 to 9999 ppm |
Conductivity Range: | 0 to 9999 μS/cm |
Temperature Range: | 0 to 80℃ or 32 to 176℃ |
Measuring Range: | 0 to 10% |
Measuring Temperature Range: | 0 to 99℃ |
Resolution: | 0.01%,0.1℃ |
pH Measuring Range: | -2 to 16 pH |
pH resolution: | 0.1pH |
pH indication error: | ±0.2% F.S. |
ORP Measuring Range: | -1000mV to 1000mV |
ORP Resolution: | 1 mV |
ORP measurement Accuracy: | ±0.5% F.S. |
pH Measuring Range: | 0 to 14pH |
pH Resolution: | 0.01pH |
pH Measuring Accuracy: | ±0.01pH |
pH Measuring Range: | 0 to 14 pH |
pH Resolution: | 0.041 pH |
pH Indication Error: | ±0.02 pH |