Double Beam Spectrophotometer ADDS-522 analyses samples in the visible to near-infrared range from 190 to 1100 nm. It features an automatic wavelength calibration system for accurate and consistent results. The USB connectivity allows seamless data transfer for easy documentation. This unit covers a broad wavelength range for UV and visible analysis. Our Double Beam Spectrophotometer is used in pharmaceuticals, biotechnology, and chemical industries for accurate analysis of absorbance. 


Display 7-inch Colour Screen
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/1/2/4/5nm
Wavelength Accuracy ± 0.1 nm 656.1 nm, ± 0.3 nm all
Wavelength Repeatability <=0.1 nm
Photometric Accuracy 0.2 % T (0 to 100 % T), ± 0.002 A (0 to 0.5 A), ± 0.004 A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 % T), 0.00 A (0 to 0.5 A), 0.002 A (0.5 to 1 A)
Photometric Range 0 to 200 % T, 0.3 to 3 A, 0 to 999 C
Stray Light <=0.03 % T, 220 nm, 360 nm
Stability ± 0.0005 A/h 500nm
Baseline Flatness ± 0.001 A
Noise 0.0005 A 500 nm
Work Mode T, A, C, E
Scanning Speed High, medium, low (Max. 3000 nm/min)
Wavelength Setting Auto
Light Source Deuterium and tungsten lamp
Detector Imported silicon photodiode
Cuvette Holder 10 mm Single-hole cell holder
Output USB drive, USB host, RS232
Power AC 110 to 220 V 50 to 60 Hz
Dimensions (L×B×H) 810×660×390 mm
Gross Weight 27 kg
  • Reduced baseline drift
  • Higher accuracy
  • High‑resolution grating
  • Double-beam optical design
  • Stainless‑steel build

Our Double Beam Spectrophotometer ADDS-522 is used in petrochemicals, agriculture, and beverage industries for precise analysis of chemical composition. 

Accessory

Quantity

10 mm glass cuvette

4 Pc

10 mm quartz cuvette (UV)

2 Pc

Power cord

1 Pc

User's Manual

1 Pc

PC software

1 Pc

Double Beam Spectrophotometer ADDS-522|Spectral Bandwidth:0.5/1/2/4/5nm|Display:7-inch Colour Screen
Double Beam Spectrophotometer ADDS-522|Reduced baseline drift|Higher accuracy

Frequently Asked Questions of Double Beam Spectrophotometer ADDS-522

1. What is the main advantage of using the Double Beam Spectrophotometer ADDS-522?

The primary advantage of the Double Beam Spectrophotometer ADDS-522 is its dual-beam design, which allows simultaneous measurement of sample and reference, reducing drift and enhancing stability. This ensures accurate and reliable results over time, especially during long experimental runs. The system compensates for lamp fluctuations and other interferences automatically. It also supports a wide spectral range and precise baseline correction. This makes it ideal for routine and advanced analytical applications in laboratories.

2. What type of light source and detector does the Double Beam Spectrophotometer ADDS-522 use?

The Double Beam Spectrophotometer ADDS-522 typically uses a combination of a deuterium lamp for UV and a tungsten halogen lamp for visible light. These provide broad spectral coverage from around 190 nm to 1100 nm. The spectrophotometer is equipped with a high-sensitivity photodiode or photomultiplier tube for accurate detection. It offers excellent resolution and low stray light performance. This ensures precise absorbance and transmittance measurements across the full spectrum.

3. Is the Double Beam Spectrophotometer ADDS-522 suitable for quantitative analysis?

Yes, the Double Beam Spectrophotometer ADDS-522 is highly suitable for quantitative analysis in chemistry, pharmaceuticals, environmental testing, and biological studies. It offers multiple calibration options, including linear and non-linear regression modes. The software supports multi-wavelength analysis, standard curve creation, and sample concentration calculation. Users can easily generate analytical reports with tabulated results and graphs. Its reliability and repeatability make it a trusted choice for routine quantification.

4. Can the Double Beam Spectrophotometer ADDS-522 store and export data?

Yes, the Double Beam Spectrophotometer ADDS-522 includes user-friendly software with data storage and export capabilities. It allows you to save measurement results, method parameters, and calibration curves for future use. Data can be exported in various formats such as CSV or PDF for further analysis or documentation. USB and LAN connectivity options are usually available for easy transfer. This enhances traceability and compliance with laboratory data management standards.

5. What are the maintenance requirements for the Double Beam Spectrophotometer ADDS-522?

The Double Beam Spectrophotometer ADDS-522 requires regular but minimal maintenance to ensure optimal performance. Users should periodically clean optical components and check lamp intensity and alignment. The software often includes built-in diagnostics to alert users of potential issues. Calibration and validation using standard reference materials should be done at scheduled intervals. With proper handling and regular upkeep, the spectrophotometer remains accurate and durable for years.

Similar Products of Dual Beam Spectrophotometer

Wavelength Range 190 to 1100 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.2 nm
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1 nm
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 2 nm
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/1/2/4/5 nm

Visible Spectrophotometer

Visible Spectrophotometer ADVS-502
Wavelength Range:320 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm
Visible Spectrophotometer ADVS-501
Wavelength Range:325 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm

Digital Spectrophotometer

Digital Spectrophotometer ADSM-503
Wavelength Range:195 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-502
Wavelength Range:325 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-501
Wavelength Range:340 to 1000 nm
Wavelength Accuracy:± 3 nm
Transmittance Range:0 to 199.9

Single Beam UV-Vis Spectrophotometer

Single Beam UV-Vis Spectrophotometer ADSS-526
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-514
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-527
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-512
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-503
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:320 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-521
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-519
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-522
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-517
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-505
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-524
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-513
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-501
Sample Volume:0.5 to 2.0 μL
Nucleic Acid Detection Range:2 to 15000 ng/μL (dsDNA) <br/> 1.32 to 9900 ng/μL (ss DNA) <br/> 1.6 to12000ng/μL (RNA)
Protein Detection Range:0.04 to 750 mg/mL (A280) <br/> 0.06 to 1119 mg/mL (BSA) <br/> 0.03 to 547 mg/mL (IgG) <br/> 0.015 to 284 mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-511
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-502
Sample Volume:0.5μl to 2μl (recommended to use 2μl)
Nucleic Acid Detection Range:2 to 37500ng /μL (dsDNA) <br/> 1.32 to 24750 ng/μL (ss DNA) <br/> 1.6 to 30000ng/μL (RNA)
Protein Detection Range:0.04 to 750mg/mL (A280) <br/> 0.06 to 1119mg/mL (BSA) <br/> 0.03 to 547mg/mL (IgG) <br/> 0.015 to 284mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-510
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-509
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/2/4
Single Beam UV-Vis Spectrophotometer ADSS-516
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-504
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-523
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-508
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-520
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-518
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-507
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-515
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-525
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-506
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/ 2/4/5 nm

Split Beam Spectrophotometer

Split Beam Spectrophotometer ADSBS-501
Optical System:Split Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm