Double Beam Spectrophotometer ADDS-511 offers ± 0.3 nm wavelength accuracy for substance identification by absorbance peaks. It provides broad wavelength coverage, often ranging from UV to visible spectrum. This unit enables real-time baseline correction, improving reproducibility in absorbance readings. The sample and reference beams travel separate paths, minimizing noise. Our Double Beam Spectrophotometer is used in pharmaceuticals, chemical analysis, and academic research for quality control of substances.


Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm 656.1 nm, ± 0.3 nm all
Wavelength Repeatability <=0.1 nm
Photometric Accuracy 0.2 % T (0 to 100 % T), ± 0.002 A (0 to 0.5 A), ± 0.004 A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 % T), 0.00 A (0 to 0.5 A), 0.002 A (0.5 to 1 A)
Photometric Range 0 to 200 % T, 0.3 to 3 A, 0 to 999 C
Stray Light <=0.03 % T, 220 nm, 360 nm
Stability ± 0.0003 A/h 500 nm
Baseline Flatness ± 0.001 A
Noise 0.0005 A 500 nm
Work Mode T, A, C, E
Scanning Speed High, medium, low (Max. 3000 nm/min)
Display 10.1 inches Colour touch screen
Light Source Deuterium and tungsten lamp
Detector Imported silicon photodiode
Cuvette Holder 10 mm Single hole cell holder
Output USB drive, USB host, RS232
Power AC 110 to 220 V 50 to 60 Hz
Dimensions (L×B×H) 810×660×390 mm
Gross Weight 27 kg
  • Reliable performance
  • Easy maintenance
  • Standard cuvette compatibility
  • Fast measurement
  • Wide wavelength range

Our Double Beam Spectrophotometer ADDS-511 is used in clinical diagnostics, biotechnology, and agricultural research for accurate detection and quantification of various substances.

Accessory

Quantity

10 mm glass cuvette

4 Pc

10 mm quartz cuvette (UV)

2 Pc

Power cord

1 Pc

User's Manual

1 Pc

PC software

1 Pc

Printer

2 year warranty

Frequently Asked Questions of Double Beam Spectrophotometer ADDS-511

1. What is the main advantage of using the Double Beam Spectrophotometer ADDS-511 over a single beam model?

The Double Beam Spectrophotometer ADDS-511 offers simultaneous measurement of sample and reference beams, minimizing drift and improving stability. This results in more accurate and reliable absorbance data, especially for long-term experiments. The design reduces errors caused by fluctuations in the light source or detector. It ensures consistent baseline correction without needing to reset between scans. Overall, it provides greater measurement precision than single-beam instruments.

2. What wavelength range does the Double Beam Spectrophotometer ADDS-511 cover?

The Double Beam Spectrophotometer ADDS-511 typically operates in the UV-Visible range, covering approximately 190–1100 nm. This wide range allows for analysis of both UV-absorbing and visible-light absorbing compounds. It supports diverse applications, from biochemical assays to material quality testing. The wavelength accuracy and repeatability make it suitable for research and quality control alike. Users can rely on consistent spectral output across the full range.

3. Can the Double Beam Spectrophotometer ADDS-511 be used for kinetic studies or time-based measurements?

Yes, the Double Beam Spectrophotometer ADDS-511 is capable of conducting kinetic studies by monitoring changes in absorbance over time. It can be programmed to take readings at set intervals, making it ideal for enzyme reactions or chemical kinetics. The instrument ensures stability during extended use due to its double-beam design. Users can observe reaction progress in real-time with high sensitivity. This function is particularly useful in biological and pharmaceutical research.

4. What types of samples and cuvettes can be used with the Double Beam Spectrophotometer ADDS-511?

The Double Beam Spectrophotometer ADDS-511 supports a variety of cuvette sizes and path lengths, including standard 10 mm quartz and glass cuvettes. It accommodates both liquid and transparent solid samples. With adjustable holders, it offers flexibility for different sample types and volumes. This versatility makes it useful across multiple industries like chemistry, life sciences, and environmental testing. Specialized accessories can also be used for micro or flow-through cuvette applications.

5. Is the Double Beam Spectrophotometer ADDS-511 user-friendly and does it come with data analysis software?

Yes, the Double Beam Spectrophotometer ADDS-511 is designed with a user-friendly interface, often featuring a touchscreen or PC connectivity with intuitive software. The included software supports functions like wavelength scanning, quantitative analysis, and data export. Users can easily store, analyze, and print results for documentation or regulatory needs. Its interface allows even non-expert users to operate it efficiently after basic training. This ease of use makes it ideal for both academic and industrial labs.

Similar Products of Dual Beam Spectrophotometer

Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 2 nm
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/1/2/4/5 nm
Wavelength Range 190 to 1100 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.2 nm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/ 1/ 2/ 5 nm
Working Modes Transmittance, Absorbance, Concentration, Energy

Visible Spectrophotometer

Visible Spectrophotometer ADVS-501
Wavelength Range:325 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm
Visible Spectrophotometer ADVS-502
Wavelength Range:320 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm

Digital Spectrophotometer

Digital Spectrophotometer ADSM-503
Wavelength Range:195 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-501
Wavelength Range:340 to 1000 nm
Wavelength Accuracy:± 3 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-502
Wavelength Range:325 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9

Single Beam UV-Vis Spectrophotometer

Single Beam UV-Vis Spectrophotometer ADSS-504
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-507
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-519
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-512
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-511
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-526
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-510
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-522
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-521
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-523
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-505
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-509
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/2/4
Single Beam UV-Vis Spectrophotometer ADSS-518
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-520
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-517
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-506
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/ 2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-524
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-508
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-503
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:320 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-527
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-515
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-514
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-513
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-501
Sample Volume:0.5 to 2.0 μL
Nucleic Acid Detection Range:2 to 15000 ng/μL (dsDNA) <br/> 1.32 to 9900 ng/μL (ss DNA) <br/> 1.6 to12000ng/μL (RNA)
Protein Detection Range:0.04 to 750 mg/mL (A280) <br/> 0.06 to 1119 mg/mL (BSA) <br/> 0.03 to 547 mg/mL (IgG) <br/> 0.015 to 284 mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-502
Sample Volume:0.5μl to 2μl (recommended to use 2μl)
Nucleic Acid Detection Range:2 to 37500ng /μL (dsDNA) <br/> 1.32 to 24750 ng/μL (ss DNA) <br/> 1.6 to 30000ng/μL (RNA)
Protein Detection Range:0.04 to 750mg/mL (A280) <br/> 0.06 to 1119mg/mL (BSA) <br/> 0.03 to 547mg/mL (IgG) <br/> 0.015 to 284mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-525
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-516
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm

Split Beam Spectrophotometer

Split Beam Spectrophotometer ADSBS-501
Optical System:Split Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm