Class II A2 Biological Safety Cabinet ADBC-507

Class II A2 Biological Safety Cabinet ADBC-507

Advalab Class II A2 Biological Safety Cabinet ADBC-507 filters air through dual HEPA filters, exhausting 30% of the air and recirculating 70%. This class II A2 biosafety cabinet has a 304 stainless steel worktop and a 5 mm tempered glass sash, and a UV lamp disinfects surfaces between runs. As a biological safety cabinet, it keeps a HEPA-filtered downflow and inflow of air to protect the operator, samples and the surrounding environment from airborne contamination. 


Filter 2 × HEPA Filters
Worktop Material 304 Stainless Steel
Cabinet Material 1.0 mm Cold-Rolled Steel
Cabinet Coating Epoxy Resin Powder Coating, Anti-Corrosive Alkali
Sash Window 5 mm Tempered Glass
UV Disinfection Lamp 1 × UV Lamp, 10 W
LED Lamp 2 × LED Lamps
Internal Waterproof Socket 2 × 10 A
Fan Built-in 300 W Centrifugal Fan
Air Exhaust 30%
Air Recirculation 70%
Control Panel LCD Digital Control Panel
Castors Heavy-Duty Castors
External Dimensions (W × D × H) 1300 × 760 × 2250 mm
Internal Dimensions (W × D × H) 1130 × 610 × 610 mm
Packing Dimensions (W × D × H) 1370 × 980 × 1650 mm
Gross Weight 250 kg

Class II A2 Biological Safety Cabinet ADBC-507 is used in microbiology and clinical laboratories, pharmaceutical and biotechnology facilities, diagnostic centers, and research and academic labs. It supports cell culture, sample handling and work with low- to moderate-risk biological agents under a sterile, HEPA-filtered airflow. 

Frequently Asked Questions of Class II A2 Biological Safety Cabinet ADBC-507

1. What are Class II A2 Biological Safety Cabinets and where are they commonly used?

Class II A2 Biological Safety Cabinets are designed to provide protection to users, laboratory samples, and the surrounding environment from harmful contaminants. These cabinets operate by maintaining a constant inflow of air to prevent exposure to hazardous substances. While simultaneously using high-efficiency ULPA filters to purify the air being recirculated and exhausted. They are used in microbiology labs, clinical research settings and diagnostic centers.

2. Is regular maintenance required for Class II A2 Biological Safety Cabinets?

Yes, regular maintenance is crucial for Class II A2 Biological Safety Cabinets to maintain optimal performance safety. These units need regular cleaning to remove residues and prevent contamination. HEPA filters must be tested regularly to ensure they effectively trap airborne particles. Airflow patterns need to be validated periodically to ensure proper laminar flow and containment.

Similar Products of Class II A2 Biological Safety Cabinet

External Dimension (W×D×H) 1500 × 750 × 2250 mm
Internal Dimension (W×D×H) 1350 × 600 × 660 mm
Max Opening Height 500 mm (20 inches)
External Dimension (W×D×H) 1800 × 755 × 2250 mm
Internal Dimension (W×D×H) 1625 × 600 × 660 mm
Max Opening Height 500 mm (22 inches)
Velocity 0.27 to 0.025 m/s
Inflow Air Speed 0.38 to 0.025 m/s
Half Peak Amplitude ≤ 3µm
External Dimensions (W×D×H) 1100 × 750 × 2250 mm
Internal Dimensions (W×D×H) 940 × 600 × 660 mm
Max Opening Height 420 mm (17 inches)

Class II B2 Biological Safety Cabinet

Class II B2 Biological Safety Cabinet ADBS-501
External Dimension (W×D×H):1100 × 750 × 2250 mm
Internal Dimension (W×D×H):940 × 600 × 660 mm
Max Opening Height:420 mm (17 inches)
Class II B2 Biological Safety Cabinet ADBS-503
External Dimension (W×D×H):1500 × 750 × 2250 mm
Internal Dimension (W×D×H):1350 × 600 × 660 mm
Max Opening Height:500 mm (20 inches)
Class II B2 Biological Safety Cabinet ADBS-502
External Dimension (W×D×H):1300 × 750 × 2250 mm
Internal Dimension (W×D×H):1150 × 600 × 660 mm
Max Opening Height:420 mm (17 inches)
Class II B2 Biological Safety Cabinet ADBS-504
External Dimension (W×D×H):1800 × 775 × 2250 mm
Internal Dimension (W×D×H):1625 × 600 × 660 mm
Max Opening Height:480 mm (20 inches)