Electric Heating Incubator ADEHI-512 offers ample capacity of 452 L for efficient storage of a wide variety of items. Our unit has a cold-rolled steel exterior with a plastic coating for long-lasting use. With a temperature range of 5°C to 100°C, it provides the ideal conditions for consistent and accurate results. The fan features six-stage speed regulation, offering customizable airflow to meet various ventilation needs. This is essential for the growth of cell cultures for various tests that require stable environmental conditions.
Volume | 452 L |
Temperature Range | RT+5 to 100°C |
Temperature Fluctuation | ±0.3°C |
Temperature Uniformity | ±0.8°C |
Heating Time | 25°C |
Recovery Time | 11°C |
Number of Shelves | 4/13 pc |
Power Consumption | 1500 W |
Internal Dimensions (W×D×H) | 600×580×1300 mm |
Housing Dimensions (W×D×H) | 774×845×1704 mm |
Package Dimensions [W×D×H] | 894×1005×1854 mm |
Net Weight | 151 kg |
Gross Weight | 180 kg |
The Electric Heating Incubator ADEHI-512 is commonly used in both laboratory and industrial environments where accurate temperature control is crucial for the incubation, cultivation, or testing of different samples.
1. Can an Electric Heating Incubator be used in a power outage?
Most Electric Heating Incubators rely on continuous electricity to function properly. During a power outage, the temperature and humidity could drop, affecting the conditions inside. To mitigate this, consider using a battery backup or a generator to maintain power during outages, especially if you’re incubating eggs that need constant care.
2. Can I use an Electric Heating Incubator for other purposes, like plant germination?
Yes, an Electric Heating Incubator can be used for plant germination. Many plants require a warm, consistent environment to sprout and grow. The controlled temperature provided by the incubator can help speed up the germination process for certain plant seeds, especially in colder climates or seasons.
3. What is the lifespan of an Electric Heating Incubator?
The lifespan of an Electric Heating Incubator can vary depending on the quality of the unit and how well it’s maintained. On average, a well-maintained incubator can last between 5 to 10 years. Regular cleaning, calibration, and inspection of components like heating elements and thermostats can extend its lifespan.
4. Can I open the Electric Heating Incubator during incubation?
It’s generally best to avoid opening the Electric Heating Incubator too often during incubation, as it can cause fluctuations in temperature and humidity. However, occasional checks may be necessary for monitoring purposes. If you must open it, do so quickly to minimize the impact on the internal environment.
5. Is it safe to use an Electric Heating Incubator indoors?
Yes, Electric Heating Incubators are designed for indoor use. However, it is important to place the incubator in a well-ventilated area away from direct sunlight, drafts, and sources of heat or cold. An environment with stable temperatures will help maintain the incubator’s performance. Ensure that the incubator is not placed in a damp or overly humid area to prevent electrical hazards.
Volume | 210 L |
Temperature Range | RT+5 to 100°C |
Temperature Fluctuation | ±0.3°C |
$2,020.00
Volume | 655 L |
Temperature Range | RT+5 to 85°C |
Temperature Resolution | 0.1°C |
$3,070.00
Volume | 1001 L |
Temperature Range | RT+5 to 85°C |
Temperature Resolution | 0.1°C |
$4,780.00
Volume | 140 L |
Temperature Range | RT+5 to 100°C |
Temperature Fluctuation | ±0.5°C |
$1,730.00
Capacity: | 30 L |
Temperature Range: | 5 °C to 65 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 50 L |
Temperature Range: | 5 °C to 65 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 270 L |
Temperature Range: | 5 °C to 65 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 80 L |
Temperature Range: | 5 °C to 65 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 160 L |
Temperature Range: | 5 °C to 65 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 20 L |
Temperature Range: | 5 °C to 65 °C |
Ambient Temperature: | 5 °C to 35 °C |
Temperature Range: | Incubation: 5℃ to 60℃ <br/> Refrigeration: 4℃ to 60℃ |
Temperature Accuracy: | 0.1℃ |
Temperature Uniformity: | ≤±1℃ [37℃] |
$17,490.00
Capacity: | 500 ml × 56 |
Temperature Range: | 5 °C to 65 °C |
Frequency: | 20 to 300 Rpm |
Capacity: | 500 ml × 3 |
Temperature Range: | 4 °C to 50 °C |
Frequency: | 20 to 300 Rpm |
Capacity: | 285 L |
Speed: | 40 to 300 rpm |
Maximum Volume: | 250 mL × 35 / 500 mL × 25 |
Capacity: | 500 ml × 28 |
Temperature Range: | 4 °C to 50 °C |
Frequency: | 20 to 300 Rpm |
Capacity: | 250 ml × 36 |
Temperature Range: | 5 °C to 65 °C |
Frequency: | 20 to 300 Rpm |
Capacity: | 500 ml × 3 |
Temperature Range: | 5 °C to 50 °C |
Frequency: | 20 to 300 Rpm |
Capacity: | 250 ml × 36 |
Temperature Range: | 5 °C to 65 °C |
Frequency: | 20 to 300 Rpm |
Capacity: | 170 L |
Speed: | 40 to 300 rpm |
Maximum Volume: | 100 mL × 48 / 250 mL × 25 |
Capacity: | 500 ml × 56 |
Temperature Range: | 5 °C to 65 °C |
Frequency: | 20 to 300 Rpm |
Capacity: | 500 ml × 28 |
Temperature Range: | 5 °C to 50 °C |
Frequency: | 20 to 300 Rpm |
Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
Illumination Range: | 0 to 15000 Lux (five-stage adjustable) |
Temperature Accuracy: | ±0.1℃ |
$4,310.00
Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
Illumination Range: | 0 to15000 Lux |
Temperature Accuracy: | ±0.1℃ |
$3,990.00
Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
Illumination Range: | 0 to15000 Lux |
Temperature Accuracy: | ±0.1℃ |
$5,250.00
Volume: | 250 L |
Temperature Range: | 4 to 70°C |
Temperature Resolution: | 0.1°C |
$3,270.00
Capacity: | 400 L |
Temperature Range: | 0 °C to 60 °C |
Fluctuation: | ± 0.5 °C |
Volume: | 150 L |
Temperature Range: | 4 to 70°C |
Temperature Resolution: | 0.1°C |
$2,750.00
Volume: | 800 L |
Temperature Range: | 4 to 70°C |
Temperature Resolution: | 0.1°C |
$8,470.00
Capacity: | 400 L |
Temperature Range: | 0 °C to 60 °C |
Fluctuation: | ± 0.5 °C |
Capacity: | 150 L |
Temperature Range: | 0 °C to 60 °C |
Fluctuation: | ± 0.5 °C |
Capacity: | 250 L |
Temperature Range: | 0 °C to 60 °C |
Fluctuation: | ± 0.5 °C |
Volume: | 400 L |
Temperature Range: | 4 to 70°C |
Temperature Resolution: | 0.1°C |
$4,500.00
Capacity: | 80 L |
Temperature Range: | 5 °C to 55 °C |
Fluctuation: | ± 0.5 °C |
Capacity: | 160 L |
Temperature Range: | 5 °C to 55 °C |
Fluctuation: | ± 0.5 °C |
Capacity: | 150 L |
Temperature Range: | 0 °C to 65 °C |
Fluctuation: | ± 0.5 °C |
Capacity: | 250 L |
Temperature Range: | 0 °C to 65 °C |
Fluctuation: | ± 0.5 °C |
Capacity: | 100 L |
Temperature Range: | 0 °C to 65 °C |
Fluctuation: | ± 0.5 °C |
Capacity: | 400 L |
Temperature Range: | 0 °C to 65 °C |
Fluctuation: | ± 0.5 °C |
Capacity: | 70 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 150 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 150 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 150 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 160 L |
Temperature: | 5 °C to 50 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 70 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 80 L |
Temperature: | 5°C to 50 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 160 L |
Temperature: | 5°C to 50 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 70 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 250 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 250 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 80 L |
Temperature: | 5°C to 50 °C |
Ambient Temperature: | 5 °C to 35 °C |
Capacity: | 250 L |
Temperature Range: | 0°C to 65 °C |
Time range: | 0 to 99.9 hr |
Capacity: | 200 L |
Temperature Range: | 0°C to 60 °C |
Time range: | 1 to 9999 min |
Capacity: | 400 L |
Temperature Range: | 0°C to 60 °C |
Time range: | 1 to 9999 min |
Capacity: | 80 L |
Temperature Range: | 0°C to 60 °C |
Time range: | 1 to 9999 min |
Capacity: | 250 L |
Temperature Range: | 0°C to 60 °C |
Time range: | 1 to 9999 min |
Capacity: | 300 L |
Temperature Range: | 0°C to 60 °C |
Time range: | 1 to 9999 min |
Capacity: | 150 L |
Temperature Range: | 0°C to 60 °C |
Time range: | 1 to 9999 min |
Capacity: | 475 L |
Temperature Range: | 10°C to 75 °C |
Time range: | 0 to 99hr59min |
Capacity: | 375 L |
Temperature Range: | 10°C to 75 °C |
Time range: | 0 to 99hr59min |
Capacity: | 800 L |
Temperature Range: | 10°C to 75 °C |
Time range: | 0 to 99hr59min |
Capacity: | 275 L |
Temperature Range: | 10°C to 75 °C |
Time range: | 0 to 99hr59min |
Capacity: | 175 L |
Temperature Range: | 10°C to 75 °C |
Time range: | 0 to 99hr59min |
Capacity: | 1075 L |
Temperature Range: | 10°C to 75 °C |
Time range: | 0 to 99hr59min |
Volume: | 100 L |
Temperature Range: | 5 to 60°C |
Temperature Resolution: | 0.1°C |
$2,190.00
Volume: | 250 L |
Temperature Range: | 5 to 60°C |
Temperature Resolution: | 0.1°C |
$2,440.00
Volume: | 150 L |
Temperature Range: | 5 to 60°C |
Temperature Resolution: | 0.1°C |
$2,470.00
Capacity: | 160 L |
Temperature: | RT 3°C to 50 °C |
Time Range: | 1 to 9999 min |
Capacity: | 80 L |
Temperature: | RT 3°C to 50 °C |
Time Range: | 1 to 9999 min |
Capacity: | 160 L |
Temperature: | RT 3°C to 50 °C |
Time Range: | 1 to 9999 min |
Capacity: | 80 L |
Temperature: | RT 3°C to 50 °C |
Time Range: | 1 to 9999 min |
Capacity: | 80 L |
Temperature: | RT 3°C to 50 °C |
Time Range: | 1 to 9999 min |
Capacity: | 160 L |
Temperature: | RT 3°C to 50 °C |
Time Range: | 1 to 9999 min |
Capacity: | 80 L |
Temperature: | RT 3°C to 50 °C |
Time Range: | 1 to 9999 min |
Capacity: | 160 L |
Temperature: | RT 3°C to 50 °C |
Time Range: | 1 to 9999 min |
Capacity: | 250 L |
Temperature Range: | With Light 10 °C to 60°C Without Light 4 °C to 60°C |
Uniformity: | ± 1 °C |
Capacity: | 250 L |
Temperature Range: | With Light 10 °C to 60°C Without Light 4 °C to 60°C |
Uniformity: | ± 1 °C |
Capacity: | 350 L |
Temperature Range: | With Light 10 °C to 60°C Without Light 4 °C to 60°C |
Uniformity: | ± 2 °C |
Capacity: | 350 L |
Temperature Range: | With Light 10 °C to 60°C Without Light 4 °C to 60°C |
Uniformity: | ± 2 °C |
Capacity: | 450 L |
Temperature Range: | With Light 10 °C to 60°C Without Light 4 °C to 60°C |
Uniformity: | ± 2 °C |
Volume: | 65L |
Temperature Range : | RT+5 to 100°C |
Temperature Fluctuation : | ±0.2°C |
$2,960.00
Volume: | 130L |
Temperature Range : | RT+5 to 100°C |
Temperature Fluctuation : | ±0.2°C |
$3,360.00
Volume: | 450 L |
Temperature Range : | RT+5 to 100°C |
Temperature Fluctuation : | ±0.2°C |
$5,630.00
Volume : | 280 L |
Temperature Range : | RT+5 to 100°C |
Temperature Fluctuation : | ±0.2°C |
$4,400.00
Volume: | 160 L |
Temperature Range: | 2°C to 65°C |
Temperature Resolution: | 0.1°C |
$1,920.00
Volume: | 70 L |
Temperature Range : | 2°C to 65°C |
Temperature Resolution: | 0.1°C |
$1,420.00
Volume: | 46 L |
Temperature Range: | 2°C to 65°C |
Temperature Resolution : | 0.1°C |
$1,330.00
Volume: | 247 L |
Temperature Range: | 2°C to 65°C |
Temperature Resolution: | 0.1°C |
$2,520.00
Temperature Range: | RT+5°C to 100°C |
Temperature Accuracy: | ±0.3°C |
Temperature Set Range: | 5°C to 100°C |
$480.00
Temperature Range: | RT + 5℃ to 150℃ |
Heating Up Rate: | ≤ 10 min, 20℃ to 100℃ <br/> ≤ 30 min, 20℃ to 150℃ |
Temperature Stability : | ±0.3℃ at 40℃ <br/> ±0.5℃ at 100℃ <br/> ±1℃ at 120℃ |
$560.00
Temperature Range: | RT + 5℃ to 150℃ |
Heating Up Rate: | ≤ 10 min, 20℃ to 100℃ <br/> ≤ 30 min, 20℃ to 150℃ |
Temperature Stability : | ±0.3℃ at 40℃ <br/> ±0.5℃ at 100℃ <br/> ±1℃ at 120℃ |
$520.00
Temperature Range: | RT-30℃ to 100℃ |
Temperature Accuracy: | ±0.3°C |
Temperature Set Range: | -10℃ to 100℃ |
$1,010.00
Temperature Range: | RT + 5℃ to 150℃ |
Heating Up Rate: | ≤ 10 min, 20℃ to 100℃ <br/> ≤ 30 min, 20℃ to 150℃ |
Temperature Stability : | ±0.3℃ at 40℃ <br/> ±0.5℃ at 100℃ <br/> ±1℃ at 120℃ |
$700.00
Temperature Range: | RT + 5℃ to 150℃ |
Heating Up Rate: | ≤ 10 min, 20℃ to 100℃ <br/> ≤ 30 min, 20℃ to 150℃ |
Temperature Stability : | ±0.3℃ at 40℃ <br/> ±0.5℃ at 100℃ <br/> ±1℃ at 120℃ |
$590.00
Temperature Range: | RT-25℃ to 100℃ |
Temperature Accuracy: | ±0.3℃ |
Temperature Set Range: | -10℃ to 100℃ |
$540.00
Temperature Range: | RT+5℃ to 100℃ |
Temperature Accuracy: | ±0.3℃ |
Temperature Set Range: | 0℃ to100℃ |
$280.00
Temperature Range: | RT+5℃ to 105℃ |
Temperature Accuracy: | ±0.3℃ |
Temperature Set Range: | 0℃ to 105℃ |
$400.00
Block Temperature Setting Range: | RT -30°C to 105°C |
Temperature Set Range: | -10°C to 105°C |
Lid Temperature Setting Range: | RT +5°C to 110°C |
$1,590.00
Temperature Range: | RT+5℃ to 100℃ |
Temperature Accuracy: | ±0.3℃ |
Temperature Set Range: | 0℃ to100℃ |
$480.00
Block Temperature Setting Range: | RT +5℃ to 105℃ |
Temperature Set Range: | 0℃ to 105℃ |
Lid Temperature Setting Range: | RT +5°C to 110°C |
$1,210.00
Temperature Control Range: | RT +5 to 80℃ |
Temperature Set Range: | 5℃ to 80℃ |
Temperature Accuracy: | ±0.3℃ |
$840.00