| Capacity | 24 Gel cards (6 column / 8 column) |
| Timing Range | 1 sec to 99 min 59 sec / infinite |
| Temperature Setting Range | 26℃ to 38℃ |
| Heating Time | ≤ 4 min (from 25℃ to 38℃) |
| Temperature Control Range | RT 5℃ to 38℃ |
| Temperature Uniformity | ≤ ± 0.5℃ |
| Temperature Accuracy | ≤ ± 0.5℃ |
| Temperature Stability | ≤ ± 0.2℃ |
| Display Accuracy | 0.1℃ |
| Fuse | 250V / 3A Ф5 × 20 |
| Voltage | AC 220V or 110V / 50 to 60 Hz |
| Dimension (L × W × H) | 364 × 234 × 152 mm |
| Net Weight | 8.2 kg |
Gel Card Incubator ADGC-501 provides precise and stable incubation for blood group reagent cards at a controlled temperature. It is used in clinical laboratories, blood banks, hospitals, and research facilities.
1. How many gel cards can Gel Card Incubator ADGC-501 hold at one time?
Gel Card Incubator ADGC-501 can hold up to 24 gel cards simultaneously. These are divided between two independent incubation chambers. Each chamber accommodates 12 gel cards. This design allows for flexible and separate processing of different samples. It enhances efficiency by enabling simultaneous incubation under controlled conditions.
2. Is the temperature control precise and stable in Gel Card Incubator ADGC-501?
Gel Card Incubator ADGC-501 is both precise and stable. It uses advanced microprocessor technology combined with PID automatic temperature control. This ensures accurate regulation and consistent heat distribution. The incubator maintains temperature uniformity and stability within tight tolerances. This level of control is essential for reliable and repeatable test results.
3. What safety features does the Gel Card Incubator ADGC-501 have?
Gel Card Incubator ADGC-501 includes multiple safety features to ensure reliable operation. It has automatic fault detection and alarm functions to alert users of any issues. Over-temperature protection safeguards the samples and device. These features help maintain a safe and stable incubation environment.
4. Does Gel Card Incubator ADGC-501 assist with reagent card removal?
Gel Card Incubator ADGC-501 assists with reagent card removal. When the cover is opened, the reagent card is automatically lifted. This feature makes it easier and more convenient for the operator to extract the card. It reduces the risk of damaging the cards or samples during removal. Overall, it enhances user efficiency and safety.
5. In which settings is the Gel Card Incubator ADGC-501 commonly used?
Gel Card Incubator ADGC-501 s commonly used in clinical laboratories, blood banks, and hospitals. It supports blood typing and immunohematology testing in these settings. Research institutions also utilize it for related studies. Its precise temperature control makes it suitable for various diagnostic applications. Overall, it is ideal for environments requiring reliable and consistent incubation.
6. What are Gel Card Incubators?
Gel Card Incubators are laboratory devices used to incubate gel cards at a controlled temperature, typically 37°C. They ensure uniform heat distribution for consistent serological and immunohematological test results. These units utilize microprocessor-based PID control for precise temperature regulation. They often feature digital displays, programmable timers, and integrated safety alarms.
7. How do Gel Card Incubators work?
Gel Card Incubators maintains a stable temperature, usually around 37°C, using microprocessor-controlled PID systems to ensure precise heat regulation. Gel cards are placed inside the incubator, where uniform temperature distribution activates the reagents within the gel matrix, facilitating accurate blood typing or antibody detection through controlled incubation periods. Built-in timers and alarms help monitor and complete the incubation process reliably.
8. What are the applications of Gel Card Incubators?
Gel Card Incubators are primarily used in clinical laboratories for blood typing, antibody screening, and crossmatching in immunohematology. They provide controlled incubation for gel cards. These units enable accurate detection of blood group antigens and antibodies, which is essential for safe blood transfusions and diagnostic testing.
| Capacity: | 20 L |
| Temperature Range: | 5 °C to 65 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 160 L |
| Temperature Range: | 5 °C to 65 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 270 L |
| Temperature Range: | 5 °C to 65 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 80 L |
| Temperature Range: | 5 °C to 65 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 50 L |
| Temperature Range: | 5 °C to 65 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 30 L |
| Temperature Range: | 5 °C to 65 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
| Illumination Range: | 0 to15000 Lux |
| Temperature Accuracy: | ±0.1℃ |
| Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
| Illumination Range: | 0 to 15000 Lux (five-stage adjustable) |
| Temperature Accuracy: | ±0.1℃ |
| Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
| Illumination Range: | 0 to15000 Lux |
| Temperature Accuracy: | ±0.1℃ |
| Capacity: | 400 L |
| Temperature Range: | 0 °C to 60 °C |
| Fluctuation: | ± 0.5 °C |
| Capacity: | 400 L |
| Temperature Range: | 0 °C to 60 °C |
| Fluctuation: | ± 0.5 °C |
| Volume: | 150 L |
| Temperature Range: | 4 to 70°C |
| Temperature Resolution: | 0.1°C |
| Capacity: | 150 L |
| Temperature Range: | 0 °C to 60 °C |
| Fluctuation: | ± 0.5 °C |
| Volume: | 250 L |
| Temperature Range: | 4 to 70°C |
| Temperature Resolution: | 0.1°C |
| Capacity: | 250 L |
| Temperature Range: | 0 °C to 60 °C |
| Fluctuation: | ± 0.5 °C |
| Volume: | 400 L |
| Temperature Range: | 4 to 70°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 800 L |
| Temperature Range: | 4 to 70°C |
| Temperature Resolution: | 0.1°C |
| Capacity: | 80 L |
| Temperature Range: | RT+5 to 50°C |
| Temperature Fluctuation: | ± 0.2°C |
| Capacity: | 160 L |
| Temperature Range: | RT+5 to 50°C |
| Temperature Fluctuation: | ± 0.2°C |
| Capacity: | 150 L |
| Temperature Range: | 0 °C to 65 °C |
| Fluctuation: | ± 0.5 °C |
| Capacity: | 250 L |
| Temperature Range: | 0 °C to 65 °C |
| Fluctuation: | ± 0.5 °C |
| Capacity: | 100 L |
| Temperature Range: | 0 °C to 65 °C |
| Fluctuation: | ± 0.5 °C |
| Capacity: | 400 L |
| Temperature Range: | 0 °C to 65 °C |
| Fluctuation: | ± 0.5 °C |
| Capacity: | 160 L |
| Temperature: | 5 °C to 50 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 150 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 160 L |
| Temperature: | 5°C to 50 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 70 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 80 L |
| Temperature: | 5°C to 50 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 250 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 150 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 250 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 70 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 80 L |
| Temperature: | 5°C to 50 °C |
| Ambient Temperature: | 5 °C to 35 °C |
| Capacity: | 250 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 70 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 150 L |
| Temperature Range: | 0°C to 65 °C |
| Time range: | 0 to 99.9 hr |
| Capacity: | 400 L |
| Temperature Range: | 0°C to 60 °C |
| Time range: | 1 to 9999 min |
| Capacity: | 80 L |
| Temperature Range: | 0°C to 60 °C |
| Time range: | 1 to 9999 min |
| Capacity: | 150 L |
| Temperature Range: | 0°C to 60 °C |
| Time range: | 1 to 9999 min |
| Capacity: | 300 L |
| Temperature Range: | 0°C to 60 °C |
| Time range: | 1 to 9999 min |
| Capacity: | 250 L |
| Temperature Range: | 0°C to 60 °C |
| Time range: | 1 to 9999 min |
| Capacity: | 200 L |
| Temperature Range: | 0°C to 60 °C |
| Time range: | 1 to 9999 min |
| Capacity: | 475 L |
| Temperature Range: | 10°C to 75 °C |
| Time range: | 0 to 99hr59min |
| Capacity: | 180 L |
| Temperature Range: | 3.0 °C to 80.0 °C |
| Temperature Uniformity: | ±0.5 °C |
| Capacity: | 1075 L |
| Temperature Range: | 10°C to 75 °C |
| Time range: | 0 to 99hr59min |
| Capacity: | 175 L |
| Temperature Range: | 10°C to 75 °C |
| Time range: | 0 to 99hr59min |
| Capacity: | 800 L |
| Temperature Range: | 10°C to 75 °C |
| Time range: | 0 to 99hr59min |
| Capacity: | 375 L |
| Temperature Range: | 10°C to 75 °C |
| Time range: | 0 to 99hr59min |
| Capacity: | 275 L |
| Temperature Range: | 10°C to 75 °C |
| Time range: | 0 to 99hr59min |
| Volume: | 100 L |
| Temperature Range: | 5 to 60°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 250 L |
| Temperature Range: | 5 to 60°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 150 L |
| Temperature Range: | 5 to 60°C |
| Temperature Resolution: | 0.1°C |
| Capacity: | 80 L |
| Temperature: | RT 3°C to 50 °C |
| Time Range: | 1 to 9999 min |
| Capacity: | 160 L |
| Temperature: | RT 3°C to 50 °C |
| Time Range: | 1 to 9999 min |
| Capacity: | 80 L |
| Temperature: | RT 3°C to 50 °C |
| Time Range: | 1 to 9999 min |
| Capacity: | 80 L |
| Temperature: | RT 3°C to 50 °C |
| Time Range: | 1 to 9999 min |
| Capacity: | 160 L |
| Temperature: | RT 3°C to 50 °C |
| Time Range: | 1 to 9999 min |
| Capacity: | 80 L |
| Temperature: | RT 3°C to 50 °C |
| Time Range: | 1 to 9999 min |
| Capacity: | 160 L |
| Temperature: | RT 3°C to 50 °C |
| Time Range: | 1 to 9999 min |
| Capacity: | 160 L |
| Temperature: | RT 3°C to 50 °C |
| Time Range: | 1 to 9999 min |
| Volume: | 130L |
| Temperature Range : | RT+5 to 100°C |
| Temperature Fluctuation : | ±0.2°C |
| Volume : | 280 L |
| Temperature Range : | RT+5 to 100°C |
| Temperature Fluctuation : | ±0.2°C |
| Volume: | 450 L |
| Temperature Range : | RT+5 to 100°C |
| Temperature Fluctuation : | ±0.2°C |
| Volume: | 65L |
| Temperature Range : | RT+5 to 100°C |
| Temperature Fluctuation : | ±0.2°C |
| Volume: | 300 L |
| Temperature Range: | RT+5 to 100°C |
| Temperature Fluctuation: | ±0.5°C |
| Volume: | 280 L |
| Temperature Range : | RT+5 to 100°C |
| Temperature Fluctuation: | ±0.3°C |
| Volume: | 210 L |
| Temperature Range : | RT+5 to 100°C |
| Temperature Fluctuation : | ±0.3°C |
| Volume: | 452 L |
| Temperature Range: | RT+5 to 85°C |
| Temperature Resolution: | 0.1°C |
| Volume : | 142 L |
| Temperature Range : | RT+5 to 85°C |
| Temperature Resolution : | 0.1°C |
| Volume: | 1001 L |
| Temperature Range: | RT+5 to 85°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 64 L |
| Temperature Range : | RT+5 to 100°C |
| Temperature Fluctuation : | ±0.3°C |
| Volume : | 76 L |
| Temperature Range : | RT+5 to 85°C |
| Temperature Resolution : | 0.1°C |
| Volume : | 234 L |
| Temperature Range : | RT+5 to 85°C |
| Temperature Resolution : | 0.1°C |
| Volume: | 70 L |
| Temperature Range: | RT+5 to 100°C |
| Temperature Fluctuation: | ±0.5°C |
| Volume: | 452 L |
| Temperature Range: | RT+5 to 100°C |
| Temperature Fluctuation: | ±0.3°C |
| Volume: | 655 L |
| Temperature Range: | RT+5 to 85°C |
| Temperature Resolution: | 0.1°C |
| Volume : | 40 L |
| Temperature Range : | RT+5 to 85°C |
| Temperature Resolution : | 0.1°C |
| Volume: | 140 L |
| Temperature Range: | RT+5 to 100°C |
| Temperature Fluctuation: | ±0.5°C |
| Volume: | 130 L |
| Temperature Range : | RT+5 to 100°C |
| Temperature Fluctuation : | ±0.3°C |
| Volume: | 70 L |
| Temperature Range : | 2°C to 65°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 46 L |
| Temperature Range: | 2°C to 65°C |
| Temperature Resolution : | 0.1°C |
| Volume: | 160 L |
| Temperature Range: | 2°C to 65°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 247 L |
| Temperature Range: | 2°C to 65°C |
| Temperature Resolution: | 0.1°C |
| Temperature Setting Range: | 0℃ to 80℃ |
| Temperature Control Range: | RT +5℃ to 80℃ |
| Capacity: | 4 microplates or deep well plates |
| Temperature Control Range: | RT +5 to 80℃ |
| Temperature Set Range: | 5℃ to 80℃ |
| Temperature Accuracy: | ±0.3℃ |
| Temperature Control Range: | RT +5℃ to 80℃ |
| Maximum Height of Plate: | 22 mm |
| Capacity: | 2 pcs microplates or culture plates |