Gel Card Incubator ADGC-501
Gel Card Incubator ADGC-501
Gel Card Incubator ADGC-501
Gel Card Incubator ADGC-501

Gel Card Incubator ADGC-501

Gel Card Incubator ADGC-501 offers a temperature setting range from 26 °C to 38 °C, providing precise conditions. It features dual independently operated incubation chambers for simultaneous yet separate processing. This system is formed by microprocessor technology combined with the PID automatic thermal control method for stable heat regulation. Designed with built-in fault alarms, it ensures reliable operation through constant monitoring and quick response to any issues. Our Gel Incubator is used for precise incubation of various blood group reagent cards.


Capacity 24 Gel cards (6 column / 8 column)
Timing Range 1 sec to 99 min 59 sec / infinite
Temperature Setting Range 26℃ to 38℃
Heating Time ≤ 4 min (from 25℃ to 38℃)
Temperature Control Range RT 5℃ to 38℃
Temperature Uniformity ≤ ± 0.5℃
Temperature Accuracy ≤ ± 0.5℃
Temperature Stability ≤ ± 0.2℃
Display Accuracy 0.1℃
Fuse 250V / 3A Ф5 × 20
Voltage AC 220V or 110V / 50 to 60 Hz
Dimension (L × W × H) 364 × 234 × 152 mm
Net Weight 8.2 kg

Gel Card Incubator ADGC-501 provides precise and stable incubation for blood group reagent cards at a controlled temperature. It is used in clinical laboratories, blood banks, hospitals, and research facilities.

Frequently Asked Questions of Gel Card Incubator ADGC-501

1. How many gel cards can Gel Card Incubator ADGC-501 hold at one time?

Gel Card Incubator ADGC-501 can hold up to 24 gel cards simultaneously. These are divided between two independent incubation chambers. Each chamber accommodates 12 gel cards. This design allows for flexible and separate processing of different samples. It enhances efficiency by enabling simultaneous incubation under controlled conditions.

2. Is the temperature control precise and stable in Gel Card Incubator ADGC-501?

Gel Card Incubator ADGC-501 is both precise and stable. It uses advanced microprocessor technology combined with PID automatic temperature control. This ensures accurate regulation and consistent heat distribution. The incubator maintains temperature uniformity and stability within tight tolerances. This level of control is essential for reliable and repeatable test results.

3. What safety features does the Gel Card Incubator ADGC-501 have?

Gel Card Incubator ADGC-501 includes multiple safety features to ensure reliable operation. It has automatic fault detection and alarm functions to alert users of any issues. Over-temperature protection safeguards the samples and device. These features help maintain a safe and stable incubation environment.

4. Does Gel Card Incubator ADGC-501 assist with reagent card removal?

Gel Card Incubator ADGC-501 assists with reagent card removal. When the cover is opened, the reagent card is automatically lifted. This feature makes it easier and more convenient for the operator to extract the card. It reduces the risk of damaging the cards or samples during removal. Overall, it enhances user efficiency and safety.

5. In which settings is the Gel Card Incubator ADGC-501 commonly used?

Gel Card Incubator ADGC-501 s commonly used in clinical laboratories, blood banks, and hospitals. It supports blood typing and immunohematology testing in these settings. Research institutions also utilize it for related studies. Its precise temperature control makes it suitable for various diagnostic applications. Overall, it is ideal for environments requiring reliable and consistent incubation.

6. What are Gel Card Incubators?

Gel Card Incubators are laboratory devices used to incubate gel cards at a controlled temperature, typically 37°C. They ensure uniform heat distribution for consistent serological and immunohematological test results. These units utilize microprocessor-based PID control for precise temperature regulation. They often feature digital displays, programmable timers, and integrated safety alarms.

7. How do Gel Card Incubators work?

Gel Card Incubators maintains a stable temperature, usually around 37°C, using microprocessor-controlled PID systems to ensure precise heat regulation. Gel cards are placed inside the incubator, where uniform temperature distribution activates the reagents within the gel matrix, facilitating accurate blood typing or antibody detection through controlled incubation periods. Built-in timers and alarms help monitor and complete the incubation process reliably.

8. What are the applications of Gel Card Incubators?

Gel Card Incubators are primarily used in clinical laboratories for blood typing, antibody screening, and crossmatching in immunohematology. They provide controlled incubation for gel cards. These units enable accurate detection of blood group antigens and antibodies, which is essential for safe blood transfusions and diagnostic testing.

Constant Temperature Incubator

Electric-Constant Temperature Incubator ADEI-501
Capacity:20 L
Temperature Range:5 °C to 65 °C
Ambient Temperature:5 °C to 35 °C
Electric-Constant Temperature Incubator ADEI-505
Capacity:160 L
Temperature Range:5 °C to 65 °C
Ambient Temperature:5 °C to 35 °C
Electric-Constant Temperature Incubator ADEI-506
Capacity:270 L
Temperature Range:5 °C to 65 °C
Ambient Temperature:5 °C to 35 °C
Electric-Constant Temperature Incubator ADEI-504
Capacity:80 L
Temperature Range:5 °C to 65 °C
Ambient Temperature:5 °C to 35 °C
Electric-Constant Temperature Incubator ADEI-503
Capacity:50 L
Temperature Range:5 °C to 65 °C
Ambient Temperature:5 °C to 35 °C
Electric-Constant Temperature Incubator ADEI-502
Capacity:30 L
Temperature Range:5 °C to 65 °C
Ambient Temperature:5 °C to 35 °C

Illumination Incubator

Illumination Incubator ADIL-501
Temperature Range:10 to 65℃ (with lighting), 0 to 60℃ (without lighting)
Illumination Range:0 to15000 Lux
Temperature Accuracy:±0.1℃
Illumination Incubator ADIL-502
Temperature Range:10 to 65℃ (with lighting), 0 to 60℃ (without lighting)
Illumination Range:0 to 15000 Lux (five-stage adjustable)
Temperature Accuracy:±0.1℃
Illumination Incubator ADIL-503
Temperature Range:10 to 65℃ (with lighting), 0 to 60℃ (without lighting)
Illumination Range:0 to15000 Lux
Temperature Accuracy:±0.1℃

Mold Incubator

Digital Mold Incubator ADDM-507
Capacity:400 L
Temperature Range:0 °C to 60 °C
Fluctuation:± 0.5 °C
Digital Mold Incubator ADDM-504
Capacity:400 L
Temperature Range:0 °C to 60 °C
Fluctuation:± 0.5 °C
Mold Incubator ADDM-501
Volume:150 L
Temperature Range:4 to 70°C
Temperature Resolution:0.1°C
Digital Mold Incubator ADDM-505
Capacity:150 L
Temperature Range:0 °C to 60 °C
Fluctuation:± 0.5 °C
Mold Incubator ADDM-502
Volume:250 L
Temperature Range:4 to 70°C
Temperature Resolution:0.1°C
Digital Mold Incubator ADDM-506
Capacity:250 L
Temperature Range:0 °C to 60 °C
Fluctuation:± 0.5 °C
Mold Incubator ADDM-503
Volume:400 L
Temperature Range:4 to 70°C
Temperature Resolution:0.1°C
Mold Incubator ADDM-508
Volume:800 L
Temperature Range:4 to 70°C
Temperature Resolution:0.1°C

Air Jacketed CO2 Incubator

Air Jacketed CO₂ Incubator ADDI-501
Capacity:80 L
Temperature Range:RT+5 to 50°C
Temperature Fluctuation:± 0.2°C
Air Jacketed CO₂ Incubator ADDI-502
Capacity:160 L
Temperature Range:RT+5 to 50°C
Temperature Fluctuation:± 0.2°C

Biological Incubator

Biological Incubator ADBT-502
Capacity:150 L
Temperature Range:0 °C to 65 °C
Fluctuation:± 0.5 °C
Biological Incubator ADBT-503
Capacity:250 L
Temperature Range:0 °C to 65 °C
Fluctuation:± 0.5 °C
Biological Incubator ADBT-501
Capacity:100 L
Temperature Range:0 °C to 65 °C
Fluctuation:± 0.5 °C
Biological Incubator ADBT-504
Capacity:400 L
Temperature Range:0 °C to 65 °C
Fluctuation:± 0.5 °C

BOD Cooling Incubator

CO₂ Incubator ADOI-502
Capacity:160 L
Temperature:5 °C to 50 °C
Ambient Temperature:5 °C to 35 °C
BOD Cooling IncubatorADIB-502
Capacity:150 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr
CO₂ Incubator ADOI-504
Capacity:160 L
Temperature:5°C to 50 °C
Ambient Temperature:5 °C to 35 °C
BOD Cooling IncubatorADIB-507
Capacity:70 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr
CO₂ Incubator ADOI-503
Capacity:80 L
Temperature:5°C to 50 °C
Ambient Temperature:5 °C to 35 °C
BOD Cooling IncubatorADIB-509
Capacity:250 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr
BOD Cooling IncubatorADIB-505
Capacity:150 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr
BOD Cooling IncubatorADIB-503
Capacity:250 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr
BOD Cooling IncubatorADIB-501
Capacity:70 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr
CO₂ Incubator ADOI-501
Capacity:80 L
Temperature:5°C to 50 °C
Ambient Temperature:5 °C to 35 °C
BOD Cooling IncubatorADIB-506
Capacity:250 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr
BOD Cooling IncubatorADIB-504
Capacity:70 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr
BOD Cooling IncubatorADIB-508
Capacity:150 L
Temperature Range:0°C to 65 °C
Time range:0 to 99.9 hr

Microbiology Cooling Incubator

Microbiology Cooling IncubatorADMC-506
Capacity:400 L
Temperature Range:0°C to 60 °C
Time range:1 to 9999 min
Microbiology Cooling IncubatorADMC-501
Capacity:80 L
Temperature Range:0°C to 60 °C
Time range:1 to 9999 min
Microbiology Cooling IncubatorADMC-502
Capacity:150 L
Temperature Range:0°C to 60 °C
Time range:1 to 9999 min
Microbiology Cooling IncubatorADMC-505
Capacity:300 L
Temperature Range:0°C to 60 °C
Time range:1 to 9999 min
Microbiology Cooling IncubatorADMC-504
Capacity:250 L
Temperature Range:0°C to 60 °C
Time range:1 to 9999 min
Microbiology Cooling IncubatorADMC-503
Capacity:200 L
Temperature Range:0°C to 60 °C
Time range:1 to 9999 min

Cooling Incubator

Cooling IncubatorADIC-504
Capacity:475 L
Temperature Range:­10°C to 75 °C
Time range:0 to 99hr59min
Cooling Incubator ADIC-507
Capacity:180 L
Temperature Range:3.0 °C to 80.0 °C
Temperature Uniformity:±0.5 °C
Cooling IncubatorADIC-506
Capacity:1075 L
Temperature Range:­10°C to 75 °C
Time range:0 to 99hr59min
Cooling IncubatorADIC-501
Capacity:175 L
Temperature Range:­10°C to 75 °C
Time range:0 to 99hr59min
Cooling IncubatorADIC-505
Capacity:800 L
Temperature Range:­10°C to 75 °C
Time range:0 to 99hr59min
Cooling IncubatorADIC-503
Capacity:375 L
Temperature Range:­10°C to 75 °C
Time range:0 to 99hr59min
Cooling IncubatorADIC-502
Capacity:275 L
Temperature Range:­10°C to 75 °C
Time range:0 to 99hr59min

Biochemical Incubator

Biochemical Incubator ADBI-503
Volume:100 L
Temperature Range:5 to 60°C
Temperature Resolution:0.1°C
Biochemical Incubator ADBI-502
Volume:250 L
Temperature Range:5 to 60°C
Temperature Resolution:0.1°C
Biochemical Incubator ADBI-501
Volume:150 L
Temperature Range:5 to 60°C
Temperature Resolution:0.1°C

Biological CO2 Incubator

Biological CO2 Incubator ADBL-505
Capacity:80 L
Temperature:RT 3°C to 50 °C
Time Range:1 to 9999 min
Biological CO2 Incubator ADBL-506
Capacity:160 L
Temperature:RT 3°C to 50 °C
Time Range:1 to 9999 min
Biological CO2 Incubator ADBL-503
Capacity:80 L
Temperature:RT 3°C to 50 °C
Time Range:1 to 9999 min
Biological CO2 Incubator ADBL-507
Capacity:80 L
Temperature:RT 3°C to 50 °C
Time Range:1 to 9999 min
Biological CO2 Incubator ADBL-502
Capacity:160 L
Temperature:RT 3°C to 50 °C
Time Range:1 to 9999 min
Biological CO2 Incubator ADBL-501
Capacity:80 L
Temperature:RT 3°C to 50 °C
Time Range:1 to 9999 min
Biological CO2 Incubator ADBL-504
Capacity:160 L
Temperature:RT 3°C to 50 °C
Time Range:1 to 9999 min
Biological CO2 Incubator ADBL-508
Capacity:160 L
Temperature:RT 3°C to 50 °C
Time Range:1 to 9999 min

Microbiology Incubator

Microbiology Incubator ADMIF-502
Volume:130L
Temperature Range :RT+5 to 100°C
Temperature Fluctuation :±0.2°C
Microbiology Incubator ADMIF-503
Volume :280 L
Temperature Range :RT+5 to 100°C
Temperature Fluctuation :±0.2°C
Microbiology Incubator ADMIF-504
Volume:450 L
Temperature Range :RT+5 to 100°C
Temperature Fluctuation :±0.2°C
Microbiology Incubator ADMIF-501
Volume:65L
Temperature Range :RT+5 to 100°C
Temperature Fluctuation :±0.2°C

Electric Heating Incubator

Electric Heating Incubator ADEHI-515
Volume:300 L
Temperature Range:RT+5 to 100°C
Temperature Fluctuation:±0.5°C
Electric Heating Incubator ADEHI-511
Volume:280 L
Temperature Range :RT+5 to 100°C
Temperature Fluctuation:±0.3°C
Electric Heating Incubator ADEHI-510
Volume:210 L
Temperature Range :RT+5 to 100°C
Temperature Fluctuation :±0.3°C
Electric Heating Incubator ADEHI-505
Volume:452 L
Temperature Range:RT+5 to 85°C
Temperature Resolution:0.1°C
Electric Heating Incubator ADEHI-503
Volume :142 L
Temperature Range :RT+5 to 85°C
Temperature Resolution :0.1°C
Electric Heating Incubator ADEHI-507
Volume:1001 L
Temperature Range:RT+5 to 85°C
Temperature Resolution:0.1°C
Electric Heating Incubator ADEHI-508
Volume:64 L
Temperature Range :RT+5 to 100°C
Temperature Fluctuation :±0.3°C
Electric Heating Incubator ADEHI-502
Volume :76 L
Temperature Range :RT+5 to 85°C
Temperature Resolution :0.1°C
Electric Heating Incubator ADEHI-504
Volume :234 L
Temperature Range :RT+5 to 85°C
Temperature Resolution :0.1°C
Electric Heating Incubator ADEHI-513
Volume:70 L
Temperature Range:RT+5 to 100°C
Temperature Fluctuation:±0.5°C
Electric Heating Incubator ADEHI-512
Volume:452 L
Temperature Range:RT+5 to 100°C
Temperature Fluctuation:±0.3°C
Electric Heating Incubator ADEHI-506
Volume:655 L
Temperature Range:RT+5 to 85°C
Temperature Resolution:0.1°C
Electric Heating Incubator ADEHI-501
Volume :40 L
Temperature Range :RT+5 to 85°C
Temperature Resolution :0.1°C
Electric Heating Incubator ADEHI-514
Volume:140 L
Temperature Range:RT+5 to 100°C
Temperature Fluctuation:±0.5°C
Electric Heating Incubator ADEHI-509
Volume:130 L
Temperature Range :RT+5 to 100°C
Temperature Fluctuation :±0.3°C

Water Jacketed Incubator

Water Jacketed Incubator ADJW-502
Volume:70 L
Temperature Range :2°C to 65°C
Temperature Resolution:0.1°C
Water Jacketed Incubator ADJW-501
Volume:46 L
Temperature Range:2°C to 65°C
Temperature Resolution :0.1°C
Water Jacketed Incubator ADJW-503
Volume:160 L
Temperature Range:2°C to 65°C
Temperature Resolution:0.1°C
Water Jacketed Incubator ADJW-504
Volume:247 L
Temperature Range:2°C to 65°C
Temperature Resolution:0.1°C

Microplate Incubator

Microplate Incubator ADMI-503
Temperature Setting Range:0℃ to 80℃
Temperature Control Range:RT +5℃ to 80℃
Capacity:4 microplates or deep well plates
Microplate Incubator ADMI-501
Temperature Control Range:RT +5 to 80℃
Temperature Set Range:5℃ to 80℃
Temperature Accuracy:±0.3℃
Microplate Incubator ADMI-502
Temperature Control Range:RT +5℃ to 80℃
Maximum Height of Plate:22 mm
Capacity:2 pcs microplates or culture plates