TSS Meter ADTSS-501
TSS Meter ADTSS-501
TSS Meter ADTSS-501
TSS Meter ADTSS-501

TSS Meter ADTSS-501

TSS Meter ADTSS-501 measures both TSS and turbidity over a range of 0 to 1000mg/L and 0 to 1000NTU respectively. With high accuracy and repeatability, it delivers consistent test results, for critical applications. With a minimal zero drift value of ≤±0.3%, it ensures stable measurements over time. Featuring a compact design, this unit maximizes convenience for a user-friendly operation. Ideal for monitoring water quality in treatment plants and environmental samples, our TSS Meter analyzes water samples efficiently.

TSS Measuring Range 0 to 1000mg/L
TSS Accuracy ±0.3mg/L or ±8%
TSS Repeatability <10mg/L: ≤±0.1mg/L
≥10mg/L: ≤±1%
TSS Calibration Method 1 point calibration
Turbidity Measuring Range 0 to 1000NTU
Turbidity Accuracy ±0.3NTU or ±8%
Turbidity Repeatability <10NTU: ≤±0.1NTU
≥10NTU: ≤±1%
Turbidity Calibration Method Four points calibration (optional 8-point calibration)
Zero Drift ≤±0.3% Full Scale for 30minutes
Operating Temperature 5 to 40℃
Storage Temperature -10℃ to 55℃
Operating Humidity 0 to 80% RH
Power Supply Lithium Battery
Protection Grade IP65
Dimensions (L×W×H) 170×72×44 mm
Weight 290 g
  • Waterproof design
  • Double light testing method
  • Built in dual detector
  • Infrared light source
  • Portable and lightweight

Our TSS Meter is used for environmental monitoring, wastewater treatment plants, chemical industries, aquaculture and in agriculture to maintain the concentration of total suspended solid in water samples.

COD Analyzer

COD Analyzer ADCOD-501
COD Range:0 to 10000 mg/L (Customized)
Principle:UV 254
Resolution:0.01 mg/L

Multi Parameter Water Quality Analyzer

Multi Parameter Water Quality Analyzer ADMWA-504
Absorbance Detection Range:0 to 3Abs
Optical Path Stability:≤±0.005Abs/30min
Absorbance Resolution:0.001Abs
Multi Parameter Water Quality Analyzer ADMWA-501
Indication Error:≤±5%
Repeatability:0.03
COD Detection Method:Potassium dichromate method, Potassium permanganate method
Multi Parameter Water Quality Analyzer ADMWA-502
COD Test Method:Potassium dichromate method<br/> Alkaline potassium permanganate
COD Measuring Range:10 to 15000mg/L<br/> 0.5 to 25mg/L
COD Test Limit:10mg/L<br/> 0.5mg/L
Multi Parameter Water Quality Analyzer ADMWA-503
COD Detection Method:Potassium dichromate method<br/> Potassium permanganate method
COD Measuring Range:10 to 15000 mg/L
COD Lower Limit of Measurement:3 mg/L

Portable Dissolved Oxygen Meter

Portable Dissolved Oxygen Meter ADPOM-501
Dissolved Oxygen Concentration Measuring Range:0 to 20 mg/L
Dissolved Oxygen Concentration Resolution:0.01 mg/L
Dissolved Oxygen Concentration Accuracy:≤±0.30 mg/L
Portable Dissolved Oxygen Meter ADPOM-502
Dissolved Oxygen Measuring Range:0 to 20 mg/L
Saturation Measuring Range:0 to 200%
Temperature Measuring Range:0 to 50℃
Portable Dissolved Oxygen Meter ADPOM-503
Dissolved Oxygen Measuring Range:0 to 20mg/L;0 to 200%
Resolution Ratio:0.01mg/L;0.1%
Measurement Accuracy:0.05mg/L;0.5%

Portable Water Quality Analyzer

Portable Water Quality Analyzer ADPWA-504
Test Parameter:Ozone
Measuring Range:0.05 to 2.5mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-502
Test Parameter:Total Chlorine
Measuring Range:0.05 to 10 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-503
Test Parameter:Chlorine dioxide
Measuring Range:0.1 to 5 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-501
Test Parameter:Residual Chlorine
Measuring Range:0.05 to 10 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-505
Test Parameter:Ammonia nitrogen
Measuring Range:0.01 to 10mg/L
Wavelength:420 nm

Turbidity Meter

Turbidity Meter ADTM-501
Measuring Range:0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU)
Accuracy:±0.1NTU or ±5%<br/> ±0.3NTU or ±8%
Repeatability:≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU

TDS Meter

TDS Meter ADTDS-501
TDS Range:0 to 9999 ppm
Conductivity Range:0 to 9999 μS/cm
Temperature Range:0 to 80℃ or 32 to 176℃

Salinity Tester

Salinity Tester ADSTR-501
Measuring Range:0 to 10%
Measuring Temperature Range:0 to 99℃
Resolution:0.01%,0.1℃

Thermoreactor

Thermoreactor ADTR-501
Temperature Control Range:Room temperature to 180℃
Digestion Temperature Range:50 to 180℃
Temperature Control Accuracy:±0.1℃
Thermoreactor ADTR-502
Temperature Control Range:45 to 180℃
Digestion Temperature:45 to 180℃
Temperature Control Accuracy:±0.1℃

pH Tester

pH Tester ADPH-501
pH Measuring Range:-2 to 16 pH
pH resolution:0.1pH
pH indication error:±0.2% F.S.

ORP Meter

ORP Meter ADOR-501
ORP Measuring Range:-1000mV to 1000mV
ORP Resolution:1 mV
ORP measurement Accuracy:±0.5% F.S.

PH/ORP Meter

PH/ORP Meter ADPO-501
pH Measuring Range:0 to 14pH
pH Resolution:0.01pH
pH Measuring Accuracy:±0.01pH
PH/ORP Meter ADPO-502
pH Measuring Range:0 to 14 pH
pH Resolution:0.041 pH
pH Indication Error:±0.02 pH