Portable Water Quality Analyzer ADPWA-503 measures chlorine dioxide levels from 0.1 to 5 mg/L. It offers an accuracy of ≤±0.05mg/L, ensuring consistent performance and high sensitivity. Using DPD photometric method, it accurately detects low chlorine concentrations. Featuring an LED diode as a light source, this unit provides stable output for reliable results. Our Water Analyzer is ideal for industrial and wastewater treatment plants and provides precise monitoring and assessment of water samples.
Test Parameter | Chlorine dioxide |
Measuring Range | 0.1 to 5 mg/L |
Wavelength | 520 nm |
Principle | DPD photometric method |
Accuracy | <1.0 mg/L, ≤±0.05mg/L, ≥1.0 mg/L, ≤±5% |
Light Source | LED light emitting diode |
Battery Life | More than 24 hours (without shutdown) |
Dimension (L×W×H) | 128×70×48 mm |
Weight | 188 g |
Our Portable Water Quality Analyzer ADPWA-503 ensures safety of drinking water by assessing contamination levels and regular monitoring of environmental samples. It is widely used in water treatment plants, aquaculture, agriculture and various industries and research laboratories.
Test Parameter | Ozone |
Measuring Range | 0.05 to 2.5mg/L |
Wavelength | 520 nm |
Test Parameter | Total Chlorine |
Measuring Range | 0.05 to 10 mg/L |
Wavelength | 520 nm |
Test Parameter | Residual Chlorine |
Measuring Range | 0.05 to 10 mg/L |
Wavelength | 520 nm |
Test Parameter | Ammonia nitrogen |
Measuring Range | 0.01 to 10mg/L |
Wavelength | 420 nm |
COD Range: | 0 to 10000 mg/L (Customized) |
Principle: | UV 254 |
Resolution: | 0.01 mg/L |
Indication Error: | ≤±5% |
Repeatability: | 0.03 |
COD Detection Method: | Potassium dichromate method, Potassium permanganate method |
COD Test Method: | Potassium dichromate method<br/> Alkaline potassium permanganate |
COD Measuring Range: | 10 to 15000mg/L<br/> 0.5 to 25mg/L |
COD Test Limit: | 10mg/L<br/> 0.5mg/L |
Absorbance Detection Range: | 0 to 3Abs |
Optical Path Stability: | ≤±0.005Abs/30min |
Absorbance Resolution: | 0.001Abs |
COD Detection Method: | Potassium dichromate method<br/> Potassium permanganate method |
COD Measuring Range: | 10 to 15000 mg/L |
COD Lower Limit of Measurement: | 3 mg/L |
Dissolved Oxygen Measuring Range: | 0 to 20mg/L;0 to 200% |
Resolution Ratio: | 0.01mg/L;0.1% |
Measurement Accuracy: | 0.05mg/L;0.5% |
Dissolved Oxygen Measuring Range: | 0 to 20 mg/L |
Saturation Measuring Range: | 0 to 200% |
Temperature Measuring Range: | 0 to 50℃ |
Dissolved Oxygen Concentration Measuring Range: | 0 to 20 mg/L |
Dissolved Oxygen Concentration Resolution: | 0.01 mg/L |
Dissolved Oxygen Concentration Accuracy: | ≤±0.30 mg/L |
Measuring Range: | 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU) |
Accuracy: | ±0.1NTU or ±5%<br/> ±0.3NTU or ±8% |
Repeatability: | ≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU |
TSS Measuring Range: | 0 to 1000mg/L |
TSS Accuracy: | ±0.3mg/L or ±8% |
TSS Repeatability: | <10mg/L: ≤±0.1mg/L <br/> ≥10mg/L: ≤±1% |
TDS Range: | 0 to 9999 ppm |
Conductivity Range: | 0 to 9999 μS/cm |
Temperature Range: | 0 to 80℃ or 32 to 176℃ |
Measuring Range: | 0 to 10% |
Measuring Temperature Range: | 0 to 99℃ |
Resolution: | 0.01%,0.1℃ |
Temperature Control Range: | 45 to 180℃ |
Digestion Temperature: | 45 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
Temperature Control Range: | Room temperature to 180℃ |
Digestion Temperature Range: | 50 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
pH Measuring Range: | -2 to 16 pH |
pH resolution: | 0.1pH |
pH indication error: | ±0.2% F.S. |
ORP Measuring Range: | -1000mV to 1000mV |
ORP Resolution: | 1 mV |
ORP measurement Accuracy: | ±0.5% F.S. |
pH Measuring Range: | 0 to 14 pH |
pH Resolution: | 0.041 pH |
pH Indication Error: | ±0.02 pH |
pH Measuring Range: | 0 to 14pH |
pH Resolution: | 0.01pH |
pH Measuring Accuracy: | ±0.01pH |