Multi Parameter Water Quality Analyzer ADMWA-504
image - 1
image - 2
image - 3
image - 4

Multi Parameter Water Quality Analyzer ADMWA-504

Multi Parameter Water Quality Analyzer ADMWA-504 provides a broad absorbance range of 0 to 3Abs, for precise detection. Its high optical path stability ensures exceptional uniformity and reliability during use. With a resolution of 0.001Abs, it allows for detailed and accurate sample testing. Equipped with a long-lasting light source, it maximizes efficiency by providing consistent illumination. Suitable for use in water treatment plants and research laboratories, our Analyzer delivers a reliable and versatile operation.


Absorbance Detection Range 0 to 3Abs
Optical Path Stability ≤±0.005Abs/30min
Absorbance Resolution 0.001Abs
Temperature 0 to 50℃
Light Life 100000 hours
Lens Lifetime 5 years
Enclosure Protection Class IP65
Rated Power 0.3 W
Operation Repeatability ≤±0.01Abs
Humidity N/A
Dimension (L×B×H) 170×72×44 mm
Weight 277g
  • Waterproof construction
  • Advanced light source
  • Data storage present
  • Compact and lightweight
  • User friendly operation

Our Multi Parameter Water Quality Analyzer ADMWA-504 helps in water quality control, monitoring and assessment in waste water treatment plants, food industries, aquaculture and pharmaceutical laboratories.

Similar Products of Multi Parameter Water Quality Analyzer

Indication Error ≤±5%
Repeatability 0.03
COD Detection Method Potassium dichromate method, Potassium permanganate method
COD Detection Method Potassium dichromate method
Potassium permanganate method
COD Measuring Range 10 to 15000 mg/L
COD Lower Limit of Measurement 3 mg/L
COD Test Method Potassium dichromate method
Alkaline potassium permanganate
COD Measuring Range 10 to 15000mg/L
0.5 to 25mg/L
COD Test Limit 10mg/L
0.5mg/L

COD Analyzer

COD Analyzer ADCOD-501
COD Range:0 to 10000 mg/L (Customized)
Principle:UV 254
Resolution:0.01 mg/L

Portable Dissolved Oxygen Meter

Portable Dissolved Oxygen Meter ADPOM-502
Dissolved Oxygen Measuring Range:0 to 20 mg/L
Saturation Measuring Range:0 to 200%
Temperature Measuring Range:0 to 50℃
Portable Dissolved Oxygen Meter ADPOM-501
Dissolved Oxygen Concentration Measuring Range:0 to 20 mg/L
Dissolved Oxygen Concentration Resolution:0.01 mg/L
Dissolved Oxygen Concentration Accuracy:≤±0.30 mg/L
Portable Dissolved Oxygen Meter ADPOM-503
Dissolved Oxygen Measuring Range:0 to 20mg/L;0 to 200%
Resolution Ratio:0.01mg/L;0.1%
Measurement Accuracy:0.05mg/L;0.5%

Portable Water Quality Analyzer

Portable Water Quality Analyzer ADPWA-501
Test Parameter:Residual Chlorine
Measuring Range:0.05 to 10 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-503
Test Parameter:Chlorine dioxide
Measuring Range:0.1 to 5 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-504
Test Parameter:Ozone
Measuring Range:0.05 to 2.5mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-502
Test Parameter:Total Chlorine
Measuring Range:0.05 to 10 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-505
Test Parameter:Ammonia nitrogen
Measuring Range:0.01 to 10mg/L
Wavelength:420 nm

Turbidity Meter

Turbidity Meter ADTM-501
Measuring Range:0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU)
Accuracy:±0.1NTU or ±5%<br/> ±0.3NTU or ±8%
Repeatability:≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU

TSS Meter

TSS Meter ADTSS-502
TSS Measuring Range:0.1 to 50000 mg/L
TSS Accuracy:± 5% FS (depending on the homogeneity of the activated sludge)
TSS Repeatability:<1%
TSS Meter ADTSS-501
TSS Measuring Range:0 to 1000mg/L
TSS Accuracy:±0.3mg/L or ±8%
TSS Repeatability:<10mg/L: ≤±0.1mg/L <br/>≥10mg/L: ≤±1%

TDS Meter

TDS Meter ADTDS-501
TDS Range:0 to 9999 ppm
Conductivity Range:0 to 9999 μS/cm
Temperature Range:0 to 80℃ or 32 to 176℃

Salinity Tester

Salinity Tester ADSTR-501
Measuring Range:0 to 10%
Measuring Temperature Range:0 to 99℃
Resolution:0.01%,0.1℃

Thermoreactor

Thermoreactor ADTR-501
Temperature Control Range:Room temperature to 180℃
Digestion Temperature Range:50 to 180℃
Temperature Control Accuracy:±0.1℃
Thermoreactor ADTR-502
Temperature Control Range:45 to 180℃
Digestion Temperature:45 to 180℃
Temperature Control Accuracy:±0.1℃

PH Tester

pH Tester ADPH-501
pH Measuring Range:-2 to 16 pH
pH resolution:0.1pH
pH indication error:±0.2% F.S.

ORP Meter

ORP Meter ADOR-501
ORP Measuring Range:-1000mV to 1000mV
ORP Resolution:1 mV
ORP measurement Accuracy:±0.5% F.S.

PH/ORP Meter

PH/ORP Meter ADPO-502
pH Measuring Range:0 to 14 pH
pH Resolution:0.041 pH
pH Indication Error:±0.02 pH
PH/ORP Meter ADPO-501
pH Measuring Range:0 to 14pH
pH Resolution:0.01pH
pH Measuring Accuracy:±0.01pH