Our Ductless Fume Hood ADDLF-501 can filter 220 to 1200 m³/h of air per hour, effectively removing hazardous fumes. It has HEPA and carbon filters to protect users from harmful vapours and particles. The control system monitors airflow and filter status for safe operation. This unit recirculates filtered air, enhancing energy efficiency and sustainability. Our Ductless Fume Hood is used in chemical labs, research and forensics to safely filter out fumes.
External Dimension (L×B×H) | 725×620×700 mm |
Internal Dimension (L×B×H) | 800×650×1900 mm |
Air treatment | 220 to1200 m³/h |
Noise | 8db |
Fan Power | 48 W to 110 W |
LED power | 6 W to 10 W |
Main Body | 1.0 mm thick cold-rolled steel with epoxy powder coating |
Work Top | 12.7 mm solid physiochemical board; ceramic or stainless-steel optional worktop |
Power supply | 220 V |
Power consumption | 2000 W |
Dimensions (L×B×H) | 100×88×120 mm |
Gross Weight | 150 Kg |
Our Ductless Fume Hood ADDLF-501 is used in laboratories, educational institutes and pharmaceuticals to safely filter and recirculate hazardous fumes without the need for external ducting.
10 A Socket 1 Pc Fan 1 Pc LED Light 1 Pc Duct 1 Pc LCD touch screen 1 Pc UV lamp 1 Pc Universal caster 1 Pc
Ductless Duct ɸ160 mm ×1 Pc
1. What safety features are included in the Ductless Fume Hood ADDLF-501?
The Ductless Fume Hood ADDLF-501 includes a clear front sash for visibility and protection, airflow alarms, and filter saturation indicators. It also has a built-in fan with variable speed control for precise airflow management. The enclosure is made from chemical-resistant materials for durability. Side panels and a sealed work area minimize the risk of exposure. These features ensure a safe working environment for laboratory personnel.
2. How often should the filters in Ductless Fume Hood ADDLF-501 be replaced?
Filter replacement depends on the type of chemicals used and the frequency of operation. Generally, filters need to be changed every 6 to 12 months for optimal performance. The unit features indicator lights or alarms that alert the user when replacement is due. Regular maintenance logs are recommended for proper tracking.
3. Where can the Ductless Fume Hood ADDLF-501 be used effectively?
Ductless Fume Hood ADDLF-501 is versatile and used across academic labs, forensic labs, biotech companies, and cosmetic testing facilities. Since it doesn’t require external ducting, it can be installed almost anywhere. It’s especially useful in temporary labs or buildings with structural limitations. The compact design allows it to fit on standard lab benches. It provides localized protection without major infrastructure changes.
4. How does the Ductless Fume Hood ADDLF-501 filter harmful substances from the air?
Ductless Fume Hood ADDLF-501 uses activated carbon filters to trap chemical fumes and optional HEPA filters to remove airborne particulates. The filtration system is designed to capture specific contaminants based on the application. Filters are sealed within the hood to prevent bypass and ensure user safety. An airflow monitoring system alerts users to any drop in performance. Regular filter replacement ensures continuous effective operation.
5. What is the main purpose of the Ductless Fume Hood ADDLF-501?
The Ductless Fume Hood ADDLF-501 is designed to protect users from hazardous fumes, vapors, and particulate matter during laboratory procedures. It filters contaminated air through advanced carbon or HEPA filters and recirculates clean air back into the lab. Unlike ducted systems, it does not require external ventilation, making it suitable for spaces without ductwork.
6. What is a Ductless Fume Hood?
A Ductless Fume Hood is a type of extraction system designed to filter air within a laboratory without the need for external ductwork. These uses advanced filtration technology, such as activated carbon and HEPA filters, to capture chemical fumes. They are requiring ventilation systems connected to the outside and return the clean air back into the room.
7. Can Ductless Fume Hoods be used for all chemicals?
While Ductless Fume Hoods are effective for many common chemical applications, they are not suitable for all types of chemicals. Some highly toxic chemicals may require more specialized containment methods. These are important to consult the manufacturer’s guidelines for compatibility with specific chemicals. These produces gases that cannot be filtered by standard carbon, a ducted system is necessary.
External Dimension (L×B×H) | 1200×650×1900 mm |
Internal Dimension (L×B×H) | 1125×620×700 mm |
Air treatment | 220 to1200 m³/h |
USD 2,800.00
External Dimension (L×B×H) | 1500×650×1900 mm |
Internal Dimension (L×B×H) | 1425×620×700 mm |
Air treatment | 220 to1200 m³/h |
USD 3,180.00
Velocity: | 0.3 to 0.6 m/s |
Power Supply: | AC220V/50Hz/0.8KW |
Fluorescent Lamp: | 28 W × 1 |
Velocity: | 0.3 to 0.6 m/s |
Power Supply: | AC220V/50Hz/0.6KW |
Fluorescent Lamp: | 28 W × 1 |
Velocity: | 0.3 to 0.6 m/s |
Power Supply: | AC220V/50Hz/0.4KW |
Fluorescent Lamp: | 21 W × 1 |
External Dimension (L×B×H): | 650×600×1000 mm |
Internal Dimension (L×B×H): | 610×580×650 mm |
Air Volume: | 420 m³/h |
USD 700.00
External Dimension (L×B×H): | 1500×650×1050 mm |
Internal Dimension (L×B×H): | 1390×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,120.00
External Dimension (L×B×H): | 1200×650×1000 mm |
Internal Dimension (L×B×H): | 1000×530×750 mm |
Air Volume: | 1850 m³/h |
USD 800.00
External Dimension (L×B×H): | 1800×800×1500 mm |
Internal Dimension (L×B×H): | 1550×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,310.00
External Dimension (L×B×H): | 800×650×1050 mm |
Internal Dimension (L×B×H): | 690×530×740 mm |
Air Volume: | 420 m³/h |
USD 890.00
External Dimension (L×B×H): | 800×600×1000 mm |
Internal Dimension (L×B×H): | 760×580×650 mm |
Air Volume: | 1850 m³/h |
USD 890.00
External Dimension (L×B×H): | 800×650×1000 mm |
Internal Dimension (L×B×H): | 600×530×750 mm |
Air Volume: | 420 m³/h |
USD 700.00
External Dimension (L×B×H): | 650×650×1000 mm |
Internal Dimension (L×B×H): | 450×530×750 mm |
Air Volume: | 420 m³/h |
USD 630.00
External Dimension (L×B×H): | 1200×800×1500 mm |
Internal Dimension (L×B×H): | 950×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,070.00
External Dimension (L×B×H): | 1000×650×1000 mm |
Internal Dimension (L×B×H): | 800×530×750 mm |
Air Volume: | 1850 m³/h |
USD 760.00
External Dimension (L×B×H): | 1500×600×1000 mm |
Internal Dimension (L×B×H): | 1460×580×650 mm |
Air Volume: | 1850 m³/h |
USD 1,120.00
External Dimension (L×B×H): | 1200×600×1000 mm |
Internal Dimension (L×B×H): | 1160×580×650 mm |
Air Volume: | 1850 m³/h |
USD 1,040.00
External Dimension (L×B×H): | 1200×650×1050 mm |
Internal Dimension (L×B×H): | 1090×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,040.00
External Dimension (L×B×H): | 1500×800×1500 mm |
Internal Dimension (L×B×H): | 1250×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,180.00
External Dimension (L×B×H): | 1000×600×1000 mm |
Internal Dimension (L×B×H): | 960×580×650 mm |
Air Volume: | 1850 m³/h |
USD 960.00
External Dimension (L×B×H): | 650×600×1000 mm |
Internal Dimension (L×B×H): | 610×580×650 mm |
Air Volume: | 1850 m³/h |
USD 700.00
External Dimension (L×B×H): | 1000×650×1050 mm |
Internal Dimension (L×B×H): | 890×530×740 mm |
Air Volume: | 1850 m³/h |
USD 960.00
External Dimension (L×B×H): | 1500×650×1000 mm |
Internal Dimension (L×B×H): | 1300×530×750 mm |
Air Volume: | 1850 m³/h |
USD 900.00
External Dimension (L×B×H): | 1200×800×2350 mm |
Internal Dimension (L×B×H): | 950×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,390.00
External Dimension (L×B×H): | 1200×650×1900 mm |
Internal Dimension (L×B×H): | 1000×530×750 mm |
Air Volume: | 1850 m³/h |
USD 1,490.00
External Dimension (W×D×H): | 1800 × 850 × 2350 mm |
Internal Dimension (W×D×H): | 1560 × 680 × 1150 mm |
Base Cabinet Dimension (W×D×H): | 1800 × 800 × 850 mm |
USD 3,130.00
External Dimension (L×B×H): | 1200×650×1900 mm |
Internal Dimension (L×B×H): | 1090×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,400.00
External Dimension (L×B×H): | 1500×650×1900 mm |
Internal Dimension (L×B×H): | 1390×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,330.00
External Dimension (W×D×H): | 1200 × 850 × 2350 mm |
Internal Dimension (W×D×H): | 960 × 680 × 1150 mm |
Base Cabinet Dimension (W×D×H): | 1200 × 800 × 850 mm |
USD 2,570.00
External Dimension (L×B×H): | 1500×650×1900 mm |
Internal Dimension (L×B×H): | 1300×530×750 mm |
Air Volume: | 1850 m³/h |
USD 790.00
External Dimension (L×B×H): | 800×650×1900 mm |
Internal Dimension (L×B×H): | 690×530×740 mm |
Air Volume: | 420 m³/h |
USD 1,240.00
External Dimension (L×B×H): | 1000×650×1900 mm |
Internal Dimension (L×B×H): | 890×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,320.00
External Dimension (L×B×H): | 800×650×1900 mm |
Internal Dimension (L×B×H): | 600×530×750 mm |
Air Volume: | 420 m³/h |
USD 1,490.00
External Dimension (W×D×H): | 1500 × 850 × 2350 mm |
Internal Dimension (W×D×H): | 1260 × 680 × 1150 mm |
Base Cabinet Dimension (W×D×H): | 1500 × 800 × 850 mm |
USD 2,900.00
External Dimension (L×B×H): | 1000×650×1900 mm |
Internal Dimension (L×B×H): | 800×530×750 mm |
Air Volume: | 1850 m³/h |
USD 1,490.00
External Dimension (L×B×H): | 1800×800×2350 mm |
Internal Dimension (L×B×H): | 1550×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,680.00
External Dimension (L×B×H): | 1500×800×2350 mm |
Internal Dimension (L×B×H): | 1250×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,530.00