| External Dimension (L×B×H) | 650 × 650 × 1050 mm |
| Internal Dimension (L×B×H) | 540 × 530 × 740 mm |
| Air Volume | 1200 m³/h |
| Surface wind Speed | 0.3–0.6 m/s |
| Noise | ~65 dB |
| Exhaust Air Diameter | ¢250 mm, 3 m soft exhaust pipe |
| Material | Steel with grayish epoxy-polyester paint |
| Fan Power | 110 W axial flow fan with air velocity regulator |
| LED power | LED lamp |
| Main Body | 1.0 mm thick steel with grayish epoxy-polyester paint |
| Inner Size | 1.0 mm thick steel lining |
| Work Top | 12.7 mm thick solid physiochemical board (anti-corrosion, anti-acid) – not included for desktop model |
| Power Consumption | 2000 W |
| Dimensions (L×B×H) | 650 × 650 × 1050 mm |
| Gross Weight | 110 kg |
Our Ducted Benchtop Fume Hood ADDBF-501 is used in pharmaceutical labs, chemical research and forensic science to safely capture and exhaust hazardous fumes.
10 A socket | 1 Pc |
Fan | 1 Pc |
Duct | 1 Pc |
LED | 1 Pc |
Speed governor | 1 Pc |
Faucet (water type) | 1 Pc |
Sink (water type) | 1 Pc |
LCD Panel | × 1 Pc |
Electric Damper | × 1 Pc |
Manual Damper | × 1 Pc |
Gas cock | × 1 Pc |
Drip Rack | × 1 Pc |
1. What are the key features of the Ducted Benchtop Fume Hood ADDBF-501 model?
The Ducted Benchtop Fume Hood ADDBF-501 includes a durable, chemical-resistant interior and adjustable airflow controls. It is equipped with a clear front sash for visibility and safety, and integrated LED lighting. The unit supports constant airflow monitoring to ensure optimal performance. It also includes options for customizable work surfaces and service fixtures. Overall, it is built for efficiency, safety, and long-term use in demanding lab settings.
2. In which environments is the Ducted Benchtop Fume Hood ADDBF-501 commonly used?
This fume hood is widely used in academic labs, research institutions, pharmaceutical labs, and chemical testing facilities. It supports procedures that generate toxic or flammable fumes. The hood ensures a clean and contained work environment. It is also suitable for forensic science and industrial R&D. Its compact benchtop design makes it ideal for limited-space labs.
3. How does the ducted system of Ducted Benchtop Fume Hood ADDBF-501 improve lab safety?
The ducted system channels harmful air directly out of the lab through external exhaust. This prevents recirculation of hazardous fumes inside the room. It significantly reduces the risk of chemical exposure for lab personnel. The system maintains negative pressure to contain contaminants effectively. This enhances both air quality and operator protection.
4. What is the primary function of the Ducted Benchtop Fume Hood ADDBF-501?
The Ducted Benchtop Fume Hood ADDBF-501 is designed to safely capture, contain, and exhaust hazardous chemical fumes and vapors during laboratory operations. It protects users by drawing contaminated air away from the work zone and venting it through an external duct system. This minimizes exposure to toxic substances and helps maintain a clean indoor air environment. The unit is particularly useful for experiments involving volatile solvents or corrosive materials. It ensures compliance with laboratory safety standards.
5. What is the primary function of the Ducted Benchtop Fume Hood ADDBF-501?
The Ducted Benchtop Fume Hood ADDBF-501 is designed to safely ventilate hazardous fumes, vapors, and airborne particles from laboratory workspaces. It connects to an external duct system to exhaust contaminated air outside. This ensures operator safety and environmental protection during chemical handling. It is ideal for applications involving volatile substances. The hood provides a secure, enclosed workspace for critical lab operations.
| External Dimension (L×B×H) | 1000×650×1000 mm |
| Internal Dimension (L×B×H) | 800×530×750 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1200×650×1000 mm |
| Internal Dimension (L×B×H) | 1000×530×750 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1200×600×1000 mm |
| Internal Dimension (L×B×H) | 1160×580×650 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 800×650×1050 mm |
| Internal Dimension (L×B×H) | 690×530×740 mm |
| Air Volume | 1200 m³/h |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| Velocity: | 0.3 to 0.6 m/s |
| Fluorescent Lamp: | 28 W × 1 |
| Dimensions (W× D × H): | 1800 × 850 × 2350 mm |
| Velocity: | 0.3 to 0.6 m/s |
| Fluorescent Lamp: | 28 W × 1 |
| Dimensions (W× D × H): | 1500 × 850 × 2350 mm |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1125×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 725×620×700 mm |
| Internal Dimension (L×B×H): | 800×650×1900 mm |
| Air treatment: | 220 to1200 m³/h |
| Velocity: | 0.4 to 0.6 m/s |
| Filter Modular: | 4 |
| Air Pressure: | 960 Pa |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1425×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 920×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1200 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 960 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1200 × 800 × 850 mm |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 420 m³/h |
| External Dimension (W×D×H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1260 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1500 × 800 × 850 mm |
| External Dimension (L×B×H): | 1200×800×2350 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1800×800×2350 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1800 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1560 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1800 × 800 × 850 mm |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (W × D × H): | 1040 × 800 × 2200 mm |
| Internal Dimension (W × D × H): | 790× 670 × 1050mm |
| Maximum Opening: | 520 mm |
| External Dimension (L×B×H): | 1500×800×2350 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Maximum Opening: | 650mm |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |