| External Dimension (W×D×H) | 1800 × 850 × 2350 mm |
| Internal Dimension (W×D×H) | 1560 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H) | 1800 × 800 × 850 mm |
| Maximum Opening Height | 1050 mm |
| Exhaust Air Volume | 1300 to 2100 m³/h |
| Air Velocity | 0.3 to 0.8 m/s |
| Exhaust Duct | 1 × 250 or 315 mmφ PP hood |
| Noise Level | ≤65 dB |
| Box 1 Packaging Dimension (W×D×H) | 1900 × 1030 × 1670 mm |
| Box 2 Packaging Dimension (W×D×H) | 1300 × 870 × 1060 mm |
| Gross Weight | 360 kg |
Our Ducted Fume Hood ADDFH-514 is utilized in labs handling harmful fumes or reactive chemicals, ensuring effective ventilation and containment to safeguard personnel and support a secure workspace.
30W LED Lamp | 1 Pc |
Bench-Mounted Single Water Tap | 1 Pc |
PP Oval Cup Sink | 1 Pc |
PP Exhaust Hood (250 or 315 mmφ) | 1 Pc |
Water-Proof Socket | 4 Pcs |
Accessory Specification Dimension Quantity PP Centrifugal Blower Power: 0.3KW, Rotating Speed: 1450 r/min, Air Volume: 2000–2500 m³/h, Wind Pressure: 30–28, Noise: 60 dB, Voltage: 220V, Frequency: 50Hz, Static Pressure: 260PA – 1 unit Gas Tap – – 1 unit Flexible Pipe with Strap PP Material with Built-in Steel Wire 4 m × Φ250 mm 1 unit
1. What role does the Ducted Fume Hood ADDFH-514 play in laboratory safety, and why is it essential?
The Ducted Fume Hood ADDFH-514 ensures lab safety by efficiently removing hazardous fumes and airborne particles through an external ventilation system. This is essential in labs using volatile chemicals, as it prevents buildup of harmful substances in the workspace. Its strong airflow, durable construction, and safety feature support make it a reliable choice for maintaining safety and cleanliness in research labs.
2. Where is the Ducted Fume Hood ADDFH-514 commonly installed, and what makes it suitable for these areas?
You will often find the Ducted Fume Hood ADDFH-514 in chemical analysis labs, pharmaceutical processing zones, and biotechnology workspaces. Its full ducted exhaust system prevents recirculation of contaminants, which is critical in areas handling toxic agents. Its robust ventilation and precise airflow control make it ideal for labs prioritizing safety and contamination control.
3. How does the airflow system of the Ducted Fume Hood ADDFH-514 contribute to operator protection?
The Ducted Fume Hood ADDFH-514 features a by-pass airflow system engineered to maintain a consistent flow of air, even when the sash is moved. It includes adjustable air velocity settings, helping establish negative pressure inside the hood to ensure no hazardous fumes escape. The airflow system confines contaminants, making it ideal for tasks requiring frequent sash movement and chemical handling.
4. What safety mechanisms are built into the Ducted Fume Hood ADDFH-514?
The Ducted Fume Hood ADDFH-514 features a chemical-resistant interior, LED lighting, and supports optional airflow sensors and alarms for enhanced safety. Emergency shutoff features can also be added to ensure immediate response during critical situations. These elements are designed to minimize exposure risks and ensure compliance with global lab safety guidelines.
5. What routine care is recommended to maintain the efficiency of the Ducted Fume Hood ADDFH-514?
For optimal performance, the Ducted Fume Hood ADDFH-514 should undergo routine cleaning with non-corrosive cleaning agents to prevent buildup of residues. Technicians should routinely check sash operation, blower function, and airflow with calibrated tools. Scheduling periodic maintenance checks and airflow validations helps maintain its safety standards and prolongs the unit’s operational life.
| External Dimension (W×D×H) | 1200 × 850 × 2350 mm |
| Internal Dimension (W×D×H) | 960 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H) | 1200 × 800 × 850 mm |
| External Dimension (L×B×H) | 1500×650×1900 mm |
| Internal Dimension (L×B×H) | 1390×530×740 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1200×650×1900 mm |
| Internal Dimension (L×B×H) | 1000×530×750 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1000×650×1900 mm |
| Internal Dimension (L×B×H) | 890×530×740 mm |
| Air Volume | 1850 m³/h |
| Velocity: | 0.3 to 0.8 m/s |
| Fluorescent Lamp: | LED purification lamp (>300 Lux) |
| Purification Area Size: | 1300 × 700 × 590 mm |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| Velocity: | 0.3 to 0.6 m/s |
| Fluorescent Lamp: | 28 W × 1 |
| Dimensions (W× D × H): | 1800 × 850 × 2350 mm |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1125×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimensions (W × D × H): | 1000 × 620 × 1245 mm |
| Internal Dimensions (W × D × H): | 981 × 574 × 934 mm |
| Filter Size: | 370 × 395 × 50 mm |
| External Dimension (L×B×H): | 725×620×700 mm |
| Internal Dimension (L×B×H): | 800×650×1900 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 920×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| Velocity: | 0.4 to 0.6 m/s |
| Filter Modular: | 4 |
| Air Pressure: | 960 Pa |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1425×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 800×600×1000 mm |
| Internal Dimension (L×B×H): | 760×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×800×1500 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×600×1000 mm |
| Internal Dimension (L×B×H): | 960×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1800×800×1500 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1000 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1050 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1050 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×600×1000 mm |
| Internal Dimension (L×B×H): | 1460×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1050 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1050 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650 × 650 × 1050 mm |
| Internal Dimension (L×B×H): | 540 × 530 × 740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 1200×800×1500 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 800×650×1000 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1000×650×1000 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1000 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×600×1000 mm |
| Internal Dimension (L×B×H): | 1160×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |