| External Dimension (L×B×H) | 1200×800×2350 mm |
| Internal Dimension (L×B×H) | 950×630×1150 mm |
| Air Volume | 1850 m³/h |
| Surface Wind Speed | Adjustable |
| Exhaust Air Diameter | 250 mm |
| Voltage | 220 V |
| Noise | 50 db |
| Rated power | 2000 W |
| Fan Power | 110 W |
| LED power | 14 W |
| Main Body | 1.0mm Cold-rolled steel with epoxy powder coating |
| Inner Size | 5mm thick compact, acid and alkali resistant |
| Work Top | 12.7mm black physicochemical board; ceramic, marble, or stainless steel optional |
| Dimensions (L×B×H) | 161×74×98 mm |
| Gross Weight | 235 Kg |
Our Ducted Fume Hood ADDFH-505 is used across pharmaceutical industries, chemical research facilities, and educational institutions to safely ventilate hazardous fumes.
10 A Socket | 1 Pc |
Fan | 1 Pc |
Duct | 1 Pc |
LED | 1 Pc |
Speed governor | 1 Pc |
Water Faucet | 1 Pc |
Water Sink | 1 Pc |
LCD Panel | × 1 Pc |
Electric Damper | × 1 Pc |
Manual Damper | × 1 Pc |
Gas cock | × 1 Pc |
Drip Rack | × 1 Pc |
1. What is the purpose of the Ducted Fume Hood ADDFH-505?
The Ducted Fume Hood ADDFH-505 is designed to safely ventilate hazardous chemical fumes, vapors, and airborne particles out of the laboratory environment. It protects users during chemical handling by drawing air away from the work surface and expelling it through an external duct system. This minimizes the risk of inhalation exposure and maintains a safe lab atmosphere. The ducted system ensures that toxic substances are not recirculated back into the lab. It is ideal for applications involving volatile chemicals.
2. What materials is the Ducted Fume Hood ADDFH-505 made from?
The Ducted Fume Hood ADDFH-505 is constructed using corrosion-resistant materials like cold-rolled steel coated with epoxy resin. This makes it durable and able to withstand harsh chemicals, acids, and solvents. Its inner chamber may also feature a compact physicochemical board or optional ceramic and stainless steel surfaces. These materials enhance the unit's chemical resistance and extend its operational life. The sash is typically made of toughened glass for safety and visibility.
3. How does the Ducted Fume Hood ADDFH-505 improve laboratory safety?
Ducted Fume Hood ADDFH-505 maintains negative air pressure within the enclosure to prevent contaminants from escaping into the laboratory. It features a transparent sash that shields users from splashes and harmful vapors. The fume hood directs airborne hazards through an external ducting system to keep the workspace clean. It also reduces the risk of fire and explosion by containing flammable vapors. The design complies with lab safety regulations and standards.
4. What kind of maintenance does the Ducted Fume Hood ADDFH-505 require?
Regular inspection and cleaning of the hood interior and duct system are essential for optimal performance. Filters, if used with pre-treatment, should be checked and replaced periodically. The sash mechanism and airflow monitor should be tested for proper function. It is important to ensure the ductwork remains unblocked for efficient exhaust. Annual servicing by a trained technician is recommended to ensure continued safety.
5. In which industries is the Ducted Fume Hood ADDFH-505 commonly used?
The Ducted Fume Hood ADDFH-505 is widely used in pharmaceutical manufacturing, chemical labs, biotechnology, academic research, and environmental testing. It is also ideal for metallurgy, petrochemical analysis, and material synthesis where hazardous fumes are generated. Its versatility makes it suitable for both industrial R&D and educational settings. The robust build allows it to handle high-demand chemical processes. It helps ensure compliance with occupational health and safety standards.
| External Dimension (L×B×H) | 1000×650×1900 mm |
| Internal Dimension (L×B×H) | 800×530×750 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1500×650×1900 mm |
| Internal Dimension (L×B×H) | 1390×530×740 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 800×650×1900 mm |
| Internal Dimension (L×B×H) | 600×530×750 mm |
| Air Volume | 420 m³/h |
| External Dimension (W×D×H) | 1500 × 850 × 2350 mm |
| Internal Dimension (W×D×H) | 1260 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H) | 1500 × 800 × 850 mm |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.8KW |
| Fluorescent Lamp: | 28 W × 1 |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.6KW |
| Fluorescent Lamp: | 28 W × 1 |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| External Dimension (L×B×H): | 725×620×700 mm |
| Internal Dimension (L×B×H): | 800×650×1900 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1425×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| Velocity: | 0.4 to 0.6 m/s |
| Filter Modular: | 4 |
| Air Pressure: | 960 Pa |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 920×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1125×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 800×650×1050 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 1500×650×1050 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1000 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1000 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×600×1000 mm |
| Internal Dimension (L×B×H): | 960×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1000 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×800×1500 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×800×1500 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1050 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1050 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650 × 650 × 1050 mm |
| Internal Dimension (L×B×H): | 540 × 530 × 740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 1500×600×1000 mm |
| Internal Dimension (L×B×H): | 1460×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×600×1000 mm |
| Internal Dimension (L×B×H): | 1160×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1000 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 800×600×1000 mm |
| Internal Dimension (L×B×H): | 760×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1800×800×1500 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |