| Temperature Range | -45℃ to +30℃ |
| Temperature Control | ±0.5℃ |
| Circulating Pump Max | 20 L/min, 1.5bar |
| Refrigerant | R404A |
| Cooling capacity at 0℃ | 1.5 kW |
| Cooling capacity at -10℃ | 1.2 kW |
| Cooling capacity at -20℃ | 0.4 kW |
| Power | 380 V / 50 Hz |
Low Temperature Circulating Chiller ADLTC-502 is used for precise cooling in laboratories, pharmaceuticals, and industrial processes. It ensures stable operation, protects sensitive instruments, and supports low-temperature testing or reactions.
1. What is the temperature range of the Low Temperature Circulating Chiller ADLTC-502?
Low Temperature Circulating Chiller ADLTC-502 offers a wide temperature range from -45°C to +30°C. This allows it to handle both very low and moderate cooling needs efficiently. Such flexibility makes it suitable for diverse laboratory and industrial processes. Users can rely on its precise temperature control for accurate and stable cooling. Overall, the system is designed to meet demanding low-temperature applications.
2. What is the maximum cooling capacity of the Low Temperature Circulating Chiller ADLTC-502 at -20°C?
Low Temperature Circulating Chiller ADLTC-502 has a cooling capacity of 0.4 kW at -20°C. This capacity ensures efficient and stable cooling at low temperatures. It is designed to support processes requiring precise temperature control. Ideal for laboratory, pharmaceutical, and industrial applications. Such system delivers reliable performance even under demanding conditions.
3. How does the Low Temperature Circulating Chiller ADLTC-502 ensure precise temperature control?
Low Temperature Circulating Chiller ADLTC-502 ensures precise temperature control through its advanced PID that is Proportional-Integral-Derivative controller. This system continuously monitors and adjusts the temperature to maintain stability. High-accuracy sensors provide real-time feedback for consistent performance. It also has digital display for easy monitoring and adjustment. These features together help achieve reliable and accurate temperature regulation.
4. What are the ideal uses for the Low Temperature Circulating Chiller ADLTC-502?
Low Temperature Circulating Chiller ADLTC-502 is ideal for laboratory experiments requiring stable low temperatures. It is commonly used in pharmaceuticals, chemical synthesis, and material testing. This Chiller supports precise temperature control in analytical instrumentation. It is also suitable for biotechnology, distillation, and environmental testing. Versatility makes it a valuable tool in both research and industry.
5. What safety features are included in the Low Temperature Circulating Chiller ADLTC-502 to prevent overheating?
Low Temperature Circulating Chiller ADLTC-502 includes over-temperature protection to automatically shut down if limits are exceeded. It has a built-in alarm system to notify users of abnormal temperature conditions. This Chiller features compressor delay protection to avoid damage from rapid cycling. A pressure relief system helps manage excess pressure buildup safely. These features work together to ensure safe and reliable operation.
6. What are Low Temperature Circulating Chillers?
Low Temperature Circulating Chillers are device designed to cool and circulate fluids at low, controlled temperatures. They are commonly used in laboratories, industrial processes, and medical systems. These chillers ensure stable performance even under varying ambient conditions. They help maintain precise temperature control for sensitive equipment or reactions. Typical fluids include water, glycol mixtures, or silicone oils.
7. What are the common uses of Low Temperature Circulating Chillers?
Low Temperature Circulating Chillers are widely used in laboratories for chemical and biological research. They support pharmaceutical manufacturing processes requiring precise thermal control. In industrial settings, they cool machinery, lasers, and reaction vessels. Such systems are also used in medical equipment and diagnostic devices. Semiconductor and electronics industries use them for heat-sensitive processes.
8. How do Low Temperature Circulating Chillers work?
Low Temperature Circulating Chillers work by using a refrigeration system to cool a thermal fluid. The chilled fluid is circulated through external equipment or systems to absorb and remove heat. A pump maintains steady flow, ensuring consistent cooling performance. Thermal controllers regulate and maintain the desired fluid temperature. These systems operate continuously to deliver stable, low-temperature conditions.
| Temperature Range | -25℃ to +35℃ |
| Temperature Control | ±0.5℃ |
| Circulating Pump Max | 20 L/min, 1.5bar |
| Temperature: | 5℃ to 35℃ |
| Working Current: | 6.2 A |
| Refrigeration capacity: | 8.5 kW |
| Type: | Integrated air cooling system |
| Cooling Capacity: | ≥ 1.2 kW |
| Pressure: | 0.08 to 0.17 MPa |
| Type: | Integrated water cooling system |
| Cooling Capacity: | ≥ 1.2 kW |
| Pressure: | 0.08 to 0.17 MPa |
| Cooling: | 6 kW (5,160 kcal/h) |
| Compressor : | Rotary Compressor |
| Refrigerant: | R22 |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 24 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Temperature Range: | 5℃ to 35℃ |
| Working Current: | 9.4 to 10.8A |
| Refrigeration capacity: | 5.48 kW |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 18 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 30 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 15 kW /h |
| Power supply: | 3N / 380 V / 50 Hz |
| Temperature Range: | 8℃ to 30℃ |
| Refrigeration capacity: | 2.7 kW |
| Flow meter : | 2.0 L/min |
| Cooling: | 6 kW (5,160 kcal/h) |
| Compressor: | Rotary Compressor |
| Refrigerant: | R22 |
| Water tank capacity: | 60 L |
| Cooling capacity: | 14 kW |
| Flow rate: | 100 L/min |
| Water tank capacity: | 60 L |
| Cooling capacity: | 8.4 kW |
| Flow rate: | 100 L/min |
| Water tank capacity: | 70 L |
| Cooling capacity: | 16.8 kW |
| Flow rate: | 100 L/min |
| Type: | Air cooled |
| Refrigerant: | R134a or R410A |
| Cooling Capacity: | 1.2–2 kW |
| Water tank capacity: | 120 L |
| Cooling capacity: | 22.4 kW |
| Flow rate: | 150 L/min |
| Water tank capacity: | 140 L |
| Cooling capacity: | 28 kW |
| Flow rate: | 200 L/min |
| Water tank capacity: | 40 L |
| Cooling capacity: | 5.6 kW |
| Flow rate: | 40 L/min |
| Water tank capacity: | 40 L |
| Cooling capacity: | 2.8 kW |
| Flow Rate: | 40 L/min |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 2.45 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 5.48 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 2.9 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 4 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 1.673 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 1.52 kW |
| Refrigerant: | R22 (Or R134a / R407c) |