Air Cooled Chiller ADCC-504

Air Cooled Chiller ADCC-504

Air Cooled Chiller ADCC-504 offers 14 kW cooling for rapid heat removal and reliable thermal stability in demanding applications. It uses a capillary tube for simple and reliable refrigerant flow control. Designed for efficient operation across wide range of temperatures it ensures consistent performance. This system is configured with intuitive controls for easy operation. Our Chiller is used for maintaining stable temperatures in electronics cooling and chemical processing.


Water tank capacity 60 L
Cooling capacity 14 kW
Flow rate 100 L/min
Circulating Water Pump 0.37 kW
Refrigerant type R22 (Or R134a / R407c)
Compressor motor 3.75 kW
Voltage / Base 3N / 380 V / 50 Hz
Dimension (L × W × H) 1300× 650 × 1300 mm
Net weight 190 kg
  • Energy-saving technology
  • Low noise operation
  • Pump overload protection
  • Compact durable design
  • Digital display system

Air Cooled Chiller ADCC-504 is used in industries like plastics manufacturing, laboratories, and laser equipment cooling. It provides precise and stable temperature control, ensuring optimal performance and protecting sensitive processes.

Frequently Asked Questions of Air Cooled Chiller ADCC-504

1. What is the cooling capacity of the Air Cooled Chiller ADCC-504?

Air Cooled Chiller ADCC-504 offers a cooling capacity of approximately 14?kW. This makes it suitable for medium to high-load industrial and laboratory applications. It ensures fast heat removal and stable temperature control. The system maintains consistent performance even under continuous operation. This capacity supports reliable cooling for sensitive equipment and processes.

2. What are the safety features present in Air Cooled Chiller ADCC-504?

Air Cooled Chiller ADCC-504 is equipped with multiple built-in safety features. It includes alerts for over-temperature, low water flow, high and low pressure. Compressor overload and phase failure protection are also integrated, helping prevent equipment damage and ensuring uninterrupted operation. An automatic shutdown function prevents damage during faults. These features ensure safe, continuous, and worry-free operation.

3. Which cooling agent is used in the Air Cooled Chiller ADCC-504?

Air Cooled Chiller ADCC-504 typically uses R22 as its cooling agent. However, it can also be configured to use more environmentally friendly alternatives like R134a or R407c. These refrigerants offer efficient heat transfer and reliable performance. The choice of refrigerant may depend on environmental regulations or user preference. Proper refrigerant selection ensures both efficiency and compliance.

4. How much power supply is required to run Air Cooled Chiller ADCC-504?

Air Cooled Chiller ADCC-504 requires a three-phase power supply of 380 volts and 50 Hz frequency. This standard industrial voltage supports its efficient and stable operation. The 3-phase setup helps the compressor and pump run smoothly under load. Proper power supply ensures optimal performance and prevents electrical issues. It is essential to use the specified power to maintain safety and equipment longevity.

5. What are the common applications of the Air Cooled Chiller ADCC-504?

Air Cooled Chiller ADCC-504 is widely used in industrial and laboratory settings. It is ideal for cooling a plastic molding machine, a laser device, or a medical instrument. The chiller provides precise temperature control critical for a sensitive process. Its reliable performance supports continuous operation in a demanding environment. Overall, it enhances efficiency and protects equipment in a wide range of applications.

6. What are Air Cooled Chillers?

Air Cooled Chillers are refrigeration systems that remove heat from a process or space using ambient air. They use fans to dissipate heat through air-cooled condenser coils. These chillers are commonly used in industrial, commercial, and HVAC applications. They are easy to install, require less maintenance, and don't need a separate cooling tower. Ideal for areas with limited water supply, they offer a cost-effective cooling solution.

7. What is the working principle of Air Cooled Chillers?

Air Cooled Chillers work by circulating refrigerant through a closed loop to absorb heat from the water or fluid being cooled. Their refrigerant vapor is compressed, raising its temperature and pressure. Fans then blow air over condenser coils to release this heat into the atmosphere, condensing the refrigerant back into a liquid. The cooled refrigerant returns to the evaporator to absorb more heat, continuing the cycle.

8. What are the benefits of Air-Cooled Chillers?

Air Cooled Chillers have lower maintenance needs compared to water-cooled systems, reducing operational costs. Their compact design makes them suitable for limited spaces and a variety of environments. They are energy-efficient, especially when equipped with variable speed compressors and fans. Additionally, Chillers are environmentally friendly by eliminating water consumption and minimizing heat discharge.

Similar Products of Air Cooled Chillers

Water tank capacity 70 L
Cooling capacity 16.8 kW
Flow rate 100 L/min
Water tank capacity 40 L
Cooling capacity 5.6 kW
Flow rate 40 L/min
Water tank capacity 140 L
Cooling capacity 28 kW
Flow rate 200 L/min
Water tank capacity 120 L
Cooling capacity 22.4 kW
Flow rate 150 L/min

Low Temperature Circulating Chillers

Low Temperature Circulating Chiller ADLTC-501
Temperature Range:-25℃ to +35℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar
Low Temperature Circulating Chiller ADLTC-502
Temperature Range:-45℃ to +30℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar

Water Chillers

Water Chiller ADWC-507
Temperature Range:5℃ to 35℃
Refrigeration capacity:30 kW/h
Water flow:200 L/min
Water Chiller ADWC-510
Type:Integrated air cooling system
Cooling Capacity:≥ 1.2 kW
Pressure:0.08 to 0.17 MPa
Water Chiller ADWC-503
Temperature:5℃ to 35℃
Working Current:6.2 A
Refrigeration capacity:8.5 kW
Water Chiller ADWC-505
Temperature Range:5℃ to 35℃
Refrigeration capacity:18 kW/h
Water flow:100 L/min
Water Chiller ADWC-501
Temperature Range:8℃ to 30℃
Refrigeration capacity:2.7 kW
Flow meter :2.0 L/min
Water Chiller ADWC-511
Type:Integrated water cooling system
Cooling Capacity:≥ 1.2 kW
Pressure:0.08 to 0.17 MPa
Water Chiller ADWC-509
Cooling:6 kW (5,160 kcal/h)
Compressor:Rotary Compressor
Refrigerant:R22
Water Chiller ADWC-504
Temperature Range:5℃ to 35℃
Refrigeration capacity:15 kW /h
Water flow:100 L/min
Water Chiller ADWC-506
Temperature Range:5℃ to 35℃
Refrigeration capacity:24 kW/h
Water flow:150 L/min
Water Chiller ADWC-508
Cooling:6 kW (5,160 kcal/h)
Compressor :Rotary Compressor
Refrigerant:R22
Water Chiller ADWC-502
Temperature Range:5℃ to 35℃
Working Current:9.4 to 10.8A
Refrigeration capacity:5.48 kW

Laser Chillers

Laser Chiller ADLAC-505
Temperature:5℃ to 30℃
Cooling capacity:4 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-501
Temperature:5℃ to 30℃
Cooling capacity:1.52 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-506
Temperature:5℃ to 30℃
Cooling capacity:5.48 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-504
Temperature:5℃ to 30℃
Cooling capacity:2.9 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-502
Temperature:5℃ to 30℃
Cooling capacity:1.673 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-503
Temperature:5℃ to 30℃
Cooling capacity:2.45 kW
Refrigerant:R22 (Or R134a / R407c)