| Temperature Range | 5℃ to 35℃ |
| Refrigeration capacity | 30 kW/h |
| Power supply | 3N / 380 V / 50 Hz |
| Water flow | 200 L/min |
| Compressor power | 7.5 kW |
| Water tank volume | 170 L |
| Dimension (L × W × H) | 1300 × 680 × 1410 mm |
| Weight | 380 kg |
Water Chiller ADWC-507 is used to provide precise and efficient temperature control. It is commonly employed in laboratories, industrial processes that require steady cooling for efficient functioning.
1. What are the common applications for the Water Chiller ADWC-507?
Water Chiller ADWC-507 is ideal for maintaining precise temperatures in laboratory environments. It supports cooling for analytical instruments, reaction vessels, and spectrometers. This unit ensures stable conditions for experiments requiring controlled thermal environments. It helps protect sensitive equipment from overheating during continuous operation.
2. What is the maintenance requirement for Water Chiller ADWC-507?
Water Chiller ADWC-507 is designed for low-maintenance operation. Regular checks include cleaning the condenser and inspecting water filters. Ensure proper fluid levels and inspect for any leaks or unusual noises. Perform periodic servicing of electrical and refrigeration components is recommended.
3. How does the water tank affect the chilling process in a Water Chiller ADWC-507?
Water Chiller ADWC-507 has water tank capacity of 170 litres. Water tank capacity directly affects temperature stability and system efficiency. A larger tank acts as a thermal buffer, reducing compressor cycling and maintaining consistent cooling. It helps manage varying cooling loads and prevents sudden temperature fluctuations. Overall, an appropriately sized tank enhances reliability and performance of the chiller system.
4. How does a Water Chiller ADWC-507 work?
Water Chiller ADWC-507 removes heat from water through a refrigeration cycle. The compressor compresses refrigerant gas, raising its temperature and pressure. The hot gas passes through the condenser, releasing heat to the surroundings. Cooled refrigerant then absorbs heat from the water in the evaporator. This cycle repeats, providing continuous cooling to maintain desired water temperature.
5. What safety features are included in the Water Chiller ADWC-507?
What safety features are included in the Water Chiller ADWC-507? Water Chiller ADWC-507 includes multiple safety features to ensure reliable operation. It has phase reverse protection to prevent damage from incorrect wiring. Pump overload protection safeguards the system against motor strain. High and low-pressure alarms monitor refrigerant levels to avoid faults. These features help protect the equipment and maintain safe, efficient performance.
6. How do a Water Chillers work?
Water Chiller works by circulating water through an evaporator where it absorbs heat from the system. They circulate coolant through closed-loop systems to absorb and remove heat. Refrigeration cycles cool the fluids, which then pass through heat exchangers or evaporators to lower temperatures effectively. Temperature sensors monitor conditions and adjust the cooling output for precise regulation. Together, these systems prevent overheating and maintain stable operational environments.
7. What maintenance is required for Water Chillers?
Maintenance of Water Chillers includes regularly cleaning or replacing filters to ensure proper airflow and water flow. Checking coolant levels and topping up as needed helps maintain efficient cooling. Inspecting pumps, compressors, and fans for wear or damage prevents breakdowns. Routine systems performance checks and leak inspections ensure reliable operation. Proper maintenance extends the lifespan and energy efficiency of the units.
8. What are the common applications of Water Chillers?
Water Chillers are commonly used to cool industrial machinery and manufacturing processes. They provide precise temperature control for laboratory equipment and medical devices. In HVAC systems, such units help regulate building temperatures efficiently. They are also used in food and beverage processing to maintain product quality. Overall, these systems support a wide range of applications requiring consistent and reliable cooling.
| Type | Integrated water cooling system |
| Cooling Capacity | ≥ 1.2 kW |
| Pressure | 0.08 to 0.17 MPa |
| Type | Integrated air cooling system |
| Cooling Capacity | ≥ 1.2 kW |
| Pressure | 0.08 to 0.17 MPa |
| Temperature Range | 5℃ to 35℃ |
| Refrigeration capacity | 18 kW/h |
| Power supply | 3N / 380 V / 50 Hz |
| Cooling | 6 kW (5,160 kcal/h) |
| Compressor | Rotary Compressor |
| Refrigerant | R22 |
| Temperature Range: | -25℃ to +35℃ |
| Temperature Control: | ±0.5℃ |
| Circulating Pump Max: | 20 L/min, 1.5bar |
| Temperature Range: | -45℃ to +30℃ |
| Temperature Control: | ±0.5℃ |
| Circulating Pump Max: | 20 L/min, 1.5bar |
| Water tank capacity: | 140 L |
| Cooling capacity: | 28 kW |
| Flow rate: | 200 L/min |
| Water tank capacity: | 60 L |
| Cooling capacity: | 8.4 kW |
| Flow rate: | 100 L/min |
| Water tank capacity: | 60 L |
| Cooling capacity: | 14 kW |
| Flow rate: | 100 L/min |
| Water tank capacity: | 120 L |
| Cooling capacity: | 22.4 kW |
| Flow rate: | 150 L/min |
| Water tank capacity: | 40 L |
| Cooling capacity: | 2.8 kW |
| Flow Rate: | 40 L/min |
| Water tank capacity: | 40 L |
| Cooling capacity: | 5.6 kW |
| Flow rate: | 40 L/min |
| Water tank capacity: | 70 L |
| Cooling capacity: | 16.8 kW |
| Flow rate: | 100 L/min |
| Type: | Air cooled |
| Refrigerant: | R134a or R410A |
| Cooling Capacity: | 1.2–2 kW |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 2.9 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 1.52 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 2.45 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 4 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 1.673 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 5.48 kW |
| Refrigerant: | R22 (Or R134a / R407c) |