Water Chiller ADWC-507
Water Chiller ADWC-507
Water Chiller ADWC-507 (Back view)

Water Chiller ADWC-507

Water Chiller ADWC-507 offers a refrigeration capacity of 30 kW, ensuring efficient cooling performance. It features rapid heat dissipation, enabling effective heat regulation. This system incorporates a durable, closed-loop design that minimizes fluid loss and contamination. Designed with multiple built-in safety protections, it enhances reliability and guards against operational faults. Our Chiller is used in laboratory applications, industrial processes and other settings needing consistent temperature control.


Temperature Range 5℃ to 35℃
Refrigeration capacity 30 kW/h
Power supply 3N / 380 V / 50 Hz
Water flow 200 L/min
Compressor power 7.5 kW
Water tank volume 170 L
Dimension (L × W × H) 1300 × 680 × 1410 mm
Weight 380 kg
  • Corrosion-resistant steel
  • Thermal regulation process
  • Reverse phase safeguard
  • Digital control module
  • Hassle-free maintenance

Water Chiller ADWC-507 is used to provide precise and efficient temperature control. It is commonly employed in laboratories, industrial processes that require steady cooling for efficient functioning.

Frequently Asked Questions of Water Chiller ADWC-507

1. What are the common applications for the Water Chiller ADWC-507?

Water Chiller ADWC-507 is ideal for maintaining precise temperatures in laboratory environments. It supports cooling for analytical instruments, reaction vessels, and spectrometers. This unit ensures stable conditions for experiments requiring controlled thermal environments. It helps protect sensitive equipment from overheating during continuous operation.

2. What is the maintenance requirement for Water Chiller ADWC-507?

Water Chiller ADWC-507 is designed for low-maintenance operation. Regular checks include cleaning the condenser and inspecting water filters. Ensure proper fluid levels and inspect for any leaks or unusual noises. Perform periodic servicing of electrical and refrigeration components is recommended.

3. How does the water tank affect the chilling process in a Water Chiller ADWC-507?

Water Chiller ADWC-507 has water tank capacity of 170 litres. Water tank capacity directly affects temperature stability and system efficiency. A larger tank acts as a thermal buffer, reducing compressor cycling and maintaining consistent cooling. It helps manage varying cooling loads and prevents sudden temperature fluctuations. Overall, an appropriately sized tank enhances reliability and performance of the chiller system.

4. How does a Water Chiller ADWC-507 work?

Water Chiller ADWC-507 removes heat from water through a refrigeration cycle. The compressor compresses refrigerant gas, raising its temperature and pressure. The hot gas passes through the condenser, releasing heat to the surroundings. Cooled refrigerant then absorbs heat from the water in the evaporator. This cycle repeats, providing continuous cooling to maintain desired water temperature.

5. What safety features are included in the Water Chiller ADWC-507?

What safety features are included in the Water Chiller ADWC-507? Water Chiller ADWC-507 includes multiple safety features to ensure reliable operation. It has phase reverse protection to prevent damage from incorrect wiring. Pump overload protection safeguards the system against motor strain. High and low-pressure alarms monitor refrigerant levels to avoid faults. These features help protect the equipment and maintain safe, efficient performance.

6. How do a Water Chillers work?

Water Chiller works by circulating water through an evaporator where it absorbs heat from the system. They circulate coolant through closed-loop systems to absorb and remove heat. Refrigeration cycles cool the fluids, which then pass through heat exchangers or evaporators to lower temperatures effectively. Temperature sensors monitor conditions and adjust the cooling output for precise regulation. Together, these systems prevent overheating and maintain stable operational environments.

7. What maintenance is required for Water Chillers?

Maintenance of Water Chillers includes regularly cleaning or replacing filters to ensure proper airflow and water flow. Checking coolant levels and topping up as needed helps maintain efficient cooling. Inspecting pumps, compressors, and fans for wear or damage prevents breakdowns. Routine systems performance checks and leak inspections ensure reliable operation. Proper maintenance extends the lifespan and energy efficiency of the units.

8. What are the common applications of Water Chillers?

Water Chillers are commonly used to cool industrial machinery and manufacturing processes. They provide precise temperature control for laboratory equipment and medical devices. In HVAC systems, such units help regulate building temperatures efficiently. They are also used in food and beverage processing to maintain product quality. Overall, these systems support a wide range of applications requiring consistent and reliable cooling.

Similar Products of Water Chillers

Type Integrated water cooling system
Cooling Capacity ≥ 1.2 kW
Pressure 0.08 to 0.17 MPa
Type Integrated air cooling system
Cooling Capacity ≥ 1.2 kW
Pressure 0.08 to 0.17 MPa
Temperature Range 5℃ to 35℃
Refrigeration capacity 18 kW/h
Power supply 3N / 380 V / 50 Hz
Cooling 6 kW (5,160 kcal/h)
Compressor Rotary Compressor
Refrigerant R22

Low Temperature Circulating Chillers

Low Temperature Circulating Chiller ADLTC-501
Temperature Range:-25℃ to +35℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar
Low Temperature Circulating Chiller ADLTC-502
Temperature Range:-45℃ to +30℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar

Air Cooled Chillers

Air Cooled Chiller ADCC-507
Water tank capacity:140 L
Cooling capacity:28 kW
Flow rate:200 L/min
Air Cooled Chiller ADCC-503
Water tank capacity:60 L
Cooling capacity:8.4 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-504
Water tank capacity:60 L
Cooling capacity:14 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-506
Water tank capacity:120 L
Cooling capacity:22.4 kW
Flow rate:150 L/min
Air Cooled Chiller ADCC-501
Water tank capacity:40 L
Cooling capacity:2.8 kW
Flow Rate:40 L/min
Air Cooled Chiller ADCC-502
Water tank capacity:40 L
Cooling capacity:5.6 kW
Flow rate:40 L/min
Air Cooled Chiller ADCC-505
Water tank capacity:70 L
Cooling capacity:16.8 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-508
Type:Air cooled
Refrigerant:R134a or R410A
Cooling Capacity:1.2–2 kW

Laser Chillers

Laser Chiller ADLAC-504
Temperature:5℃ to 30℃
Cooling capacity:2.9 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-501
Temperature:5℃ to 30℃
Cooling capacity:1.52 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-503
Temperature:5℃ to 30℃
Cooling capacity:2.45 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-505
Temperature:5℃ to 30℃
Cooling capacity:4 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-502
Temperature:5℃ to 30℃
Cooling capacity:1.673 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-506
Temperature:5℃ to 30℃
Cooling capacity:5.48 kW
Refrigerant:R22 (Or R134a / R407c)