| Water tank capacity | 120 L |
| Cooling capacity | 22.4 kW |
| Flow rate | 150 L/min |
| Circulating Water Pump | 1.1 kW |
| Refrigerant type | R22 (Or R134a / R407c) |
| Compressor motor | 6 kW |
| Voltage | 3N / 380 V / 50 Hz |
| Dimension (L × W × H) | 1500× 750 × 1500 mm |
| Net weight | 380 kg |
Air Cooled Chiller ADCC-506 is commonly used in laser equipment cooling, and pharmaceutical processing to maintain precise temperature control. Its efficient cooling keeps machinery stable, preventing overheating and ensuring quality.
1. For which industry is the Air Cooled Chiller ADCC-506 suitable?
Air Cooled Chiller ADCC-506 is suitable for a variety of industries that require precise and reliable cooling. It is commonly used in plastic processing, where maintaining consistent mold temperatures is critical. The unit is also ideal for laser equipment cooling to prevent overheating during operation. Additionally, it supports pharmaceutical manufacturing by ensuring stable environmental conditions.
2. Does the Air Cooled Chiller ADCC-506 require an external cooling tower?
Air Cooled Chiller ADCC-506 does not require an external cooling tower. It is designed with a built-in condenser that uses ambient air to dissipate heat. This plug-and-play design simplifies installation and reduces space requirements. It is ideal for locations where water availability or cooling tower installation is limited. The integrated system ensures efficient cooling without the need for additional external equipment.
3. Hoe much is the power consumption of the compressor motor in Air Cooled Chiller ADCC-506?
The compressor motor of the Air Cooled Chiller ADCC-506 operates at a power rating of 6 kW, ensuring robust and efficient cooling performance. This power capacity is well-suited for industrial applications requiring stable and reliable temperature control. The motor's design contributes to the chiller's overall energy efficiency and operational stability. Its performance is optimized for continuous operation in demanding environments.
4. How is the refrigerant flow controlled in Air Cooled Chiller ADCC-506?
The refrigerant flow in the Air Cooled Chiller ADCC-506 is controlled using a capillary tube system. This method offers a simple and reliable way to regulate refrigerant flow without complex parts. It provides precise throttling to maintain stable cooling performance. This system is ideal for low to medium cooling loads. Its simplicity also means less maintenance is required.
5. What type of condenser does the Air Cooled Chiller ADCC-506 have?
Air Cooled Chiller ADCC-506 uses a brass-set copper tube condenser with corrugated aluminium fins, enhancing heat transfer efficiency and durability. This design is ideal for demanding industrial applications. It balances thermal conductivity with cost-effectiveness. This ensures reliable and consistent cooling performance in various environments.
6. What are Air Cooled Chillers?
Air Cooled Chillers are refrigeration systems that remove heat from a process or space using ambient air. They use fans to dissipate heat through air-cooled condenser coils. These chillers are commonly used in industrial, commercial, and HVAC applications. They are easy to install, require less maintenance, and don't need a separate cooling tower. Ideal for areas with limited water supply, they offer a cost-effective cooling solution.
7. What is the working principle of Air Cooled Chillers?
Air Cooled Chillers work by circulating refrigerant through a closed loop to absorb heat from the water or fluid being cooled. Their refrigerant vapor is compressed, raising its temperature and pressure. Fans then blow air over condenser coils to release this heat into the atmosphere, condensing the refrigerant back into a liquid. The cooled refrigerant returns to the evaporator to absorb more heat, continuing the cycle.
8. What are the benefits of Air-Cooled Chillers?
Air Cooled Chillers have lower maintenance needs compared to water-cooled systems, reducing operational costs. Their compact design makes them suitable for limited spaces and a variety of environments. They are energy-efficient, especially when equipped with variable speed compressors and fans. Additionally, Chillers are environmentally friendly by eliminating water consumption and minimizing heat discharge.
| Water tank capacity | 60 L |
| Cooling capacity | 8.4 kW |
| Flow rate | 100 L/min |
| Water tank capacity | 60 L |
| Cooling capacity | 14 kW |
| Flow rate | 100 L/min |
| Water tank capacity | 40 L |
| Cooling capacity | 2.8 kW |
| Flow Rate | 40 L/min |
| Type | Air cooled |
| Refrigerant | R134a or R410A |
| Cooling Capacity | 1.2–2 kW |
| Temperature Range: | -45℃ to +30℃ |
| Temperature Control: | ±0.5℃ |
| Circulating Pump Max: | 20 L/min, 1.5bar |
| Temperature Range: | -25℃ to +35℃ |
| Temperature Control: | ±0.5℃ |
| Circulating Pump Max: | 20 L/min, 1.5bar |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 18 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Temperature: | 5℃ to 35℃ |
| Working Current: | 6.2 A |
| Refrigeration capacity: | 8.5 kW |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 30 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Cooling: | 6 kW (5,160 kcal/h) |
| Compressor : | Rotary Compressor |
| Refrigerant: | R22 |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 15 kW /h |
| Power supply: | 3N / 380 V / 50 Hz |
| Type: | Integrated air cooling system |
| Cooling Capacity: | ≥ 1.2 kW |
| Pressure: | 0.08 to 0.17 MPa |
| Cooling: | 6 kW (5,160 kcal/h) |
| Compressor: | Rotary Compressor |
| Refrigerant: | R22 |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 24 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Temperature Range: | 5℃ to 35℃ |
| Working Current: | 9.4 to 10.8A |
| Refrigeration capacity: | 5.48 kW |
| Temperature Range: | 8℃ to 30℃ |
| Refrigeration capacity: | 2.7 kW |
| Flow meter : | 2.0 L/min |
| Type: | Integrated water cooling system |
| Cooling Capacity: | ≥ 1.2 kW |
| Pressure: | 0.08 to 0.17 MPa |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 4 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 2.45 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 5.48 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 1.52 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 1.673 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 2.9 kW |
| Refrigerant: | R22 (Or R134a / R407c) |