Air Cooled Chiller ADCC-503

Air Cooled Chiller ADCC-503

Air Cooled Chiller ADCC-503 is equipped with a 2.25 kW compressor motor, ensuring efficient heat management. This unit is built with a capillary tube refrigerant control system that delivers smooth operation with minimal maintenance. It has multi-alert mechanism designed to continuously monitor the Chiller for potential issues for reliable performance. Designed with user-friendly digital controls it allows easy monitoring and adjustment of cooling parameters. Ideal for providing efficient cooling in industrial processes and equipment.


Water tank capacity 60 L
Cooling capacity 8.4 kW
Flow rate 100 L/min
Circulating Water Pump 0.37 kW
Refrigerant type R22 (Or R134a / R407c)
Compressor motor 2.25 kW
Voltage / Base 3N / 380 V / 50 Hz
Dimension (L × W × H) 1150 × 600 × 1100 mm
Net weight 160 kg
  • Precise temperature control
  • Energy-efficient operation
  • Intuitive digital panel
  • Quiet compressor performance
  • Convenient control system

Air Cooled Chiller ADCC-503 is widely used to cool machinery and processes in industries such as plastics, lasers, and laboratories. It provides efficient temperature control by dissipating heat through ambient air.

Frequently Asked Questions of Air Cooled Chiller ADCC-503

1. What type of refrigerant does the Air Cooled Chiller ADCC-503 use?

Air Cooled Chiller ADCC-503 primarily uses R22 refrigerant, which is effective for standard cooling needs. For environmentally friendly options, it also supports refrigerants like R134a and R407c. These alternatives offer lower ozone depletion potential and improved energy efficiency. Proper refrigerant handling ensures optimal performance and compliance with environmental standards.

2. Can Air Cooled Chiller ADCC-503 be used in laboratory settings?

Air Cooled Chiller ADCC-503 can be used in laboratory settings. This unit offers precise temperature control, which is essential for sensitive lab equipment. It has compact design fits well in limited space environments. Such Chiller operates quietly, minimizing disruption in lab workflows. Advanced safety features ensure stable and reliable performance for continuous lab use.

3. What safety features does the Air Cooled Chiller ADCC-503 include?

Air Cooled Chiller ADCC-503 includes several safety features to ensure reliable and secure operation. It is equipped with a multiple alert system that monitors temperature, water flow, and pressure. In case of abnormalities, it triggers visual and audible alarms and can automatically shut down to prevent damage. Phase protection safeguards against power supply issues like phase loss or imbalance. These features help minimize downtime and extend the life of the unit.

4. What is the flow rate of the built-in pump in Air Cooled Chiller ADCC-503?

The built-in pump of Air Cooled Chiller ADCC-503 offers a flow rate of approximately 100 litres per minute. This high flow capacity ensures efficient circulation of chilled water throughout the system. It supports consistent cooling performance, even in demanding applications. The flow rate is suitable for a variety of industrial and laboratory processes requiring stable temperature control.

5. Can Air Cooled Chiller ADCC-503 operate in hot environments?

Air Cooled Chiller ADCC-503 can operate effectively in hot environments. It is designed to perform reliably in ambient temperatures up to around 35°C. This unit has proper ventilation around that is essential to maintain optimal cooling efficiency. Designed with an air-cooled system, it dissipates heat efficiently without relying on external water sources. This makes it suitable for use in warm industrial and lab settings with consistent performance.

6. What are Air Cooled Chillers?

Air Cooled Chillers are refrigeration systems that remove heat from a process or space using ambient air. They use fans to dissipate heat through air-cooled condenser coils. These chillers are commonly used in industrial, commercial, and HVAC applications. They are easy to install, require less maintenance, and don't need a separate cooling tower. Ideal for areas with limited water supply, they offer a cost-effective cooling solution.

7. What is the working principle of Air Cooled Chillers?

Air Cooled Chillers work by circulating refrigerant through a closed loop to absorb heat from the water or fluid being cooled. Their refrigerant vapor is compressed, raising its temperature and pressure. Fans then blow air over condenser coils to release this heat into the atmosphere, condensing the refrigerant back into a liquid. The cooled refrigerant returns to the evaporator to absorb more heat, continuing the cycle.

8. What are the benefits of Air-Cooled Chillers?

Air Cooled Chillers have lower maintenance needs compared to water-cooled systems, reducing operational costs. Their compact design makes them suitable for limited spaces and a variety of environments. They are energy-efficient, especially when equipped with variable speed compressors and fans. Additionally, Chillers are environmentally friendly by eliminating water consumption and minimizing heat discharge.

Similar Products of Air Cooled Chillers

Water tank capacity 120 L
Cooling capacity 22.4 kW
Flow rate 150 L/min
Water tank capacity 140 L
Cooling capacity 28 kW
Flow rate 200 L/min
Water tank capacity 60 L
Cooling capacity 14 kW
Flow rate 100 L/min
Water tank capacity 40 L
Cooling capacity 2.8 kW
Flow Rate 40 L/min

Low Temperature Circulating Chillers

Low Temperature Circulating Chiller ADLTC-501
Temperature Range:-25℃ to +35℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar
Low Temperature Circulating Chiller ADLTC-502
Temperature Range:-45℃ to +30℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar

Water Chillers

Water Chiller ADWC-505
Temperature Range:5℃ to 35℃
Refrigeration capacity:18 kW/h
Power supply:3N / 380 V / 50 Hz
Water Chiller ADWC-506
Temperature Range:5℃ to 35℃
Refrigeration capacity:24 kW/h
Power supply:3N / 380 V / 50 Hz
Water Chiller ADWC-509
Cooling:6 kW (5,160 kcal/h)
Compressor:Rotary Compressor
Refrigerant:R22
Water Chiller ADWC-511
Type:Integrated water cooling system
Cooling Capacity:≥ 1.2 kW
Pressure:0.08 to 0.17 MPa
Water Chiller ADWC-504
Temperature Range:5℃ to 35℃
Refrigeration capacity:15 kW /h
Power supply:3N / 380 V / 50 Hz
Water Chiller ADWC-502
Temperature Range:5℃ to 35℃
Working Current:9.4 to 10.8A
Refrigeration capacity:5.48 kW
Water Chiller ADWC-507
Temperature Range:5℃ to 35℃
Refrigeration capacity:30 kW/h
Power supply:3N / 380 V / 50 Hz
Water Chiller ADWC-510
Type:Integrated air cooling system
Cooling Capacity:≥ 1.2 kW
Pressure:0.08 to 0.17 MPa
Water Chiller ADWC-508
Cooling:6 kW (5,160 kcal/h)
Compressor :Rotary Compressor
Refrigerant:R22
Water Chiller ADWC-501
Temperature Range:8℃ to 30℃
Refrigeration capacity:2.7 kW
Flow meter :2.0 L/min
Water Chiller ADWC-503
Temperature:5℃ to 35℃
Working Current:6.2 A
Refrigeration capacity:8.5 kW

Laser Chillers

Laser Chiller ADLAC-505
Temperature:5℃ to 30℃
Cooling capacity:4 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-502
Temperature:5℃ to 30℃
Cooling capacity:1.673 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-504
Temperature:5℃ to 30℃
Cooling capacity:2.9 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-506
Temperature:5℃ to 30℃
Cooling capacity:5.48 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-503
Temperature:5℃ to 30℃
Cooling capacity:2.45 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-501
Temperature:5℃ to 30℃
Cooling capacity:1.52 kW
Refrigerant:R22 (Or R134a / R407c)