| Temperature | 5℃ to 30℃ |
| Cooling capacity | 4 kW |
| Refrigerant | R22 (Or R134a / R407c) |
| Compressor power | 1.23 × 1 |
| Water Tank Volume | 22 L |
| Water Flow | 33 L/min |
| Power supply | 1N / 220V / 50Hz |
| Dimension (L × B × H) | 500 × 470 × 905 mm |
| Net Weight | 70 kg |
Laser Chiller ADLAC-505 is used to maintain precise temperature control in sensitive equipment and preventing overheating. It is ideal for applications like laser systems and CNC machines where stable cooling is critical for accuracy and longevity.
1. What kind of refrigerant does the Laser Chiller ADLAC-505 use?
Laser Chiller ADLAC-505 primarily uses R22 refrigerant, known for its efficient cooling capabilities. Depending on customer needs or regulations, it can also operate with alternative refrigerants like R134a or R407c. These options allow flexibility to suit various cooling requirements. The choice of refrigerant helps ensure compliance with environmental and safety standards. This adaptability makes the Chiller suitable for a wide range of applications.
2. How large is the water reservoir in the Laser Chiller ADLAC-505?
Laser Chiller ADLAC-505 is equipped with a 22-liter water reservoir, designed to ensure optimal cooling performance. This stainless-steel tank offers durability and resistance to corrosion. Their integrated water pump delivers a flow rate of 33 litres per minute, facilitating efficient heat exchange.
3. What is the cooling capacity of Laser Chiller ADLAC-505?
Laser Chiller ADLAC-505 has a cooling capacity of 4?kW, making it suitable for medium-duty industrial and laboratory applications. This capacity ensures efficient heat removal from equipment such as lasers and CNC machines. It helps maintain optimal operating temperatures, improving system performance and longevity. This cooling efficiency supports stable thermal management across various processes.
4. Is Laser Chiller ADLAC-505 easy to operate and monitor?
Laser Chiller ADLAC-505 is designed for user-friendly operation. It features a microcomputer control panel that allows for precise temperature adjustments. Real-time monitoring ensures consistent performance and quick issue detection. The intuitive interface makes it easy to set parameters and view system status. This simplifies operation even for users without technical expertise.
5. Where can the Laser Chiller ADLAC-505 be used?
Laser Chiller ADLAC-505 is ideal for applications requiring precise temperature control. It is commonly used with laser systems, CNC machines, and semiconductor equipment. Laboratories and research facilities also rely on it for stable cooling of sensitive instruments. Its compact size and efficient design make it suitable for both industrial and lab environments. This versatility ensures reliable performance across a wide range of cooling needs.
6. What are Laser Chillers?
Laser chillers are units that cool laser systems by removing excess heat during operation. They maintain stable temperatures to ensure lasers work efficiently and reliably. By circulating cooled liquid, they absorb and remove excess heat from laser components. Such Chillers are essential for extending the lifespan and accuracy of laser equipment.
7. What types of lasers are used by Laser Chillers?
Many types of lasers require Laser Chillers to manage heat during operation. Common examples include CO2 lasers, fiber lasers, and diode lasers. These lasers often operate at high power levels, producing significant heat that needs efficient cooling. Such Chillers are used across industries like manufacturing, medical treatments, and scientific research. The choice of systems depends on the specific laser type and its cooling demands.
8. How do Laser Chillers work?
Laser Chillers work by circulating a coolant through laser components to absorb heat generated during operation. The heated coolant then passes through a refrigeration system that cools it down. This cooled liquid is continuously cycled back to maintain a stable temperature. By efficiently removing heat, laser chillers prevent overheating and ensure consistent laser performance.
| Temperature | 5℃ to 30℃ |
| Cooling capacity | 1.52 kW |
| Refrigerant | R22 (Or R134a / R407c) |
| Temperature | 5℃ to 30℃ |
| Cooling capacity | 5.48 kW |
| Refrigerant | R22 (Or R134a / R407c) |
| Temperature | 5℃ to 30℃ |
| Cooling capacity | 2.9 kW |
| Refrigerant | R22 (Or R134a / R407c) |
| Temperature | 5℃ to 30℃ |
| Cooling capacity | 1.673 kW |
| Refrigerant | R22 (Or R134a / R407c) |
| Temperature Range: | -45℃ to +30℃ |
| Temperature Control: | ±0.5℃ |
| Circulating Pump Max: | 20 L/min, 1.5bar |
| Temperature Range: | -25℃ to +35℃ |
| Temperature Control: | ±0.5℃ |
| Circulating Pump Max: | 20 L/min, 1.5bar |
| Cooling: | 6 kW (5,160 kcal/h) |
| Compressor: | Rotary Compressor |
| Refrigerant: | R22 |
| Temperature Range: | 5℃ to 35℃ |
| Working Current: | 9.4 to 10.8A |
| Refrigeration capacity: | 5.48 kW |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 30 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Temperature: | 5℃ to 35℃ |
| Working Current: | 6.2 A |
| Refrigeration capacity: | 8.5 kW |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 24 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Type: | Integrated water cooling system |
| Cooling Capacity: | ≥ 1.2 kW |
| Pressure: | 0.08 to 0.17 MPa |
| Cooling: | 6 kW (5,160 kcal/h) |
| Compressor : | Rotary Compressor |
| Refrigerant: | R22 |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 18 kW/h |
| Power supply: | 3N / 380 V / 50 Hz |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 15 kW /h |
| Power supply: | 3N / 380 V / 50 Hz |
| Type: | Integrated air cooling system |
| Cooling Capacity: | ≥ 1.2 kW |
| Pressure: | 0.08 to 0.17 MPa |
| Temperature Range: | 8℃ to 30℃ |
| Refrigeration capacity: | 2.7 kW |
| Flow meter : | 2.0 L/min |
| Water tank capacity: | 120 L |
| Cooling capacity: | 22.4 kW |
| Flow rate: | 150 L/min |
| Water tank capacity: | 60 L |
| Cooling capacity: | 14 kW |
| Flow rate: | 100 L/min |
| Water tank capacity: | 40 L |
| Cooling capacity: | 5.6 kW |
| Flow rate: | 40 L/min |
| Water tank capacity: | 140 L |
| Cooling capacity: | 28 kW |
| Flow rate: | 200 L/min |
| Type: | Air cooled |
| Refrigerant: | R134a or R410A |
| Cooling Capacity: | 1.2–2 kW |
| Water tank capacity: | 70 L |
| Cooling capacity: | 16.8 kW |
| Flow rate: | 100 L/min |
| Water tank capacity: | 40 L |
| Cooling capacity: | 2.8 kW |
| Flow Rate: | 40 L/min |
| Water tank capacity: | 60 L |
| Cooling capacity: | 8.4 kW |
| Flow rate: | 100 L/min |